Error Messages - Bosch Rexroth CS660 Operator's Manual

Spreader controller
Hide thumbs Also See for Rexroth CS660:
Table of Contents

Advertisement

8

Error Messages

Error Messages
#
ERROR BLAST TOO LONG
1
ERROR DEICE BLST TOO LONG 2
ERROR OVERSPEED
3
ERROR SPIN PROP
4
ERROR CONV PROP
5
ERROR CROSS1 PROP
6
ERROR CROSS2 PROP
7
ERROR NO MATL DETECT
8
ERROR NO LIQ DETECT
9
ERROR NO GROUNDSPEED
10 Check cable/sensor
ERROR NO CONVEYOR
11 Check cable/sensor
ERROR NO LIQUID
12 Check cable/sensor
ERROR NO DEICE
13 Check cable/sensor
Warning Messages
Suggested Solution
BB3 SYSTEM ERROR
Turn off blast, reset timer
RC COMMUNICATION ERROR
Turn off blast, reset timer
BOOMS CLOSED
Slow down, reset max speed
JOY 1 COMMUNICATION ERROR
Check cables, replace coil
JOY 2 COMMUNICATION ERROR
Check cables, replace coil
NO GATE SENSOR
Check cables, replace coil
GATE POSITION ZERO
Check cables, replace coil
NO GROUND SPEED SIMULATION
Load material, check sensor
UNDER APPLICATION-SPINNER
Load material, check sensor
UNDER APPLICATION-CONVEYOR
UNDER APPLICATION-PREWET
UNDER APPLICATION-ANTI-ICING
CALIB:GND SPD PULSES TOO LOW 37 Too few or no pulses, recalibrate
SPINNER MAX RPM TOO LOW
CONVEYOR MAX RPM TOO LOW
PREWET MAX HZ TOO LOW
ANTI_ICING MAX HZ TOO LOW
WRONG SPINNER CONTROL MODE
WRONG PREWET CONTROL MODE
WRONG ANTI-ICING CTRL MODE
WRONG CROSS-CONVEYOR MODE
WT/REV TOO LOW
WT/REV TOO HIGH
PREWET PULSES/GAL TOO LOW
PREWET PULSES/GAL TOO HIGH
ANTI-ICING PULSES/GAL TOO LOW
ANTI-ICING PULSES/GAL TOO HIGH
SPNR WIDTH AT 0 RPM TOO LOW
SPNR WIDTH PER RPM TOO LOW
GATE MOVEMENT TOO LOW
GATE AT CALIBRATION TOO LOW
SPN SENSOR PULSES TOO LOW
CONV SENSOR PULSES TOO LOW
#
Suggested Solution
22 Check if RCE present, Reboot
23 Comm failure between display and RC
24 Need at least one boom to work
25 Comm failure between RC and Joy 1
26 Comm failure between RC and Joy 2
27 Check gate sensor, cable break
28 Gate closed in READBACK mode
29 Speed Simulation mode stopped
30 Spinner not able to reach desired RPM
31 Rate or spd too hi, incorrect calib
32 Rate or spd too hi, incorrect calib
33 Rate or spd too hi, incorrect calib
38 Bad or no sensor
39 Bad or no sensor
40 Too few pulses, or sensor failed
41 Too few pulses, or sensor failed
42 Auto null not allowed for MAN mode
44 Auto-null or calibration not allowed
45 Check Anti-icing or CrsCnv modes
46 Check Cross-Conv mode setting
47 Check conv sensor, recalibrate
48 Check conv sensor, recalibrate
49 Check prewet sensor, recalibrate
50 Check prewet sensor, recalibrate
51 Check anti-icing sensor,re calibrate
52 Check anti-icing sensor, recalibrate
53 Check spinner sensor, recalibrate
54 Check max width, and recalibrate
55 Calibration gate move too low
57 Calib gate needs to be non-zero
58 Spin sensor pulses 0 or too low
59 Conv sensor pulses 0 or too low
Bosch Rexroth Canada I December 2020 ı Revision 2.0
13/13

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rexroth cs661

Table of Contents