Make sure that the vehicle is stationary (ground speed = 0)
-
Press UP and DOWN buttons to adjust simulated ground speed.
-
Under the simulation mode, the system still counts the spreading information into log, so please clear
that by resetting screen totals and retrieving logging data with USB.
9.2
Material change
Press the down arrow, then press once more to enter the sub, sub menu.
the material change screen.
Press SOLID to change solid material.
A reminder screen of the calibrated gate of new solid material will last for 5 seconds.
10

ERROR MESSAGES

A beep will come on for 4 seconds when an error occurs, then goes off. Some error codes show on the screen
first and come back on 3 minutes later if it is not resolved, while others stay on the screen until power cycle or
resolved.
Error Messages
BLAST2LONG
OVERSPEED
SPIN OUTPUT
COIL SHORT
11

UNLOAD

Press UNLD to unload and the text "UNLOADING" shows on the screen. (Note: The vehicle must be stationary.)
Suggested Solution
Turn off blast
Slow down, reset max speed
Check cables, replace coil
Check cables, replace coil
If
MAT is there, Press it to enter
DONE
Cycle power Needed?
No
No
Yes
Yes
DEI1-3C
0%
UNLOAD
EXIT