F U N C T I O N A L F E AT U R E S / T E C H N I C A L D ATA
Type of operation:
Operating modes:
Operating temperature:
Measured temperature:
Temperature probe:
Measurement accuracy:
Preset programs:
Time programming resolution:
Max. n° of temperature changes:
Temperature levels:
Temperature set point resolution:
Antifreeze temperature:
High temperature protection level:
Manual temperature:
Regulation differential:
Party function:
Holiday function:
Temporary temperature forcing:
Self-learning thermal gradient:
Unit of measure:
Interval between two successive
measurements:
Output contact:
Power supply:
Dimensions:
heating and air conditioning
automatic, manual,
antifreeze/high temperature protection
-5 °C ÷ +45 °C
0 °C ÷ +45 °C
NTC, 100kΩ at 25°C
±0.5°C to 20°C
n° 2 weekly programs
15 minutes
4 per hour
n° 3 levels (T1 ,T2,T3), programmable from 5 to 40 °C
differentiated between air conditioning and heating
0.1 °C
adjustable from 2 to 7 °C
adjustable from 30 to 40 °C
adjustable from 5 to 40 °C
adjustable from 0.2 to 2 °C
timed from 1 to 23 hours
timed from 1 to 99 days
settable
selectable with max. 2 hours advance
°C or °F
1 minute
relay, without potential
1 NA/NC 5A (AC1)/2A (AC15), 250V ac
mains (230V ac) – normal operation - ML1220 3V
rechargeable battery-in the case of a power blackout
2 ELOS modules
44