6-6. DSP
The DSP circuit consists of a DSP (IC102) and processes
the base band signal. The DSP operates on an external clock
of 18.432MHz (the same as the IC108), the I/O section op-
erates at 3.3V and the core section operates at 1.5V. The
DSP carries out the following processes:
• 4 Level FSK processing
• Analog FM pre-emphasis/de-emphasis
• Vocoder processing between audio codec and modula-
tion/demodulation
• CAI processing, such as error correction encoding
• QT/DQT encoding/decoding
• LTR encoding/decoding
• DTMF encoding/decoding
• MSK encoding/decoding
• 2-tone encoding/decoding
• Compressor/expander processing
• Voice scrambler processing
• Transmit/receive audio fi ltering processing
• Microphone amplifi er AGC processing
• Audio mute processing
• Modulation level processing
7. Power Supply Circuit
The battery voltage (+B) is provided from the battery
terminal on the TX/RX unit (X57). The battery voltage passes
through the 2.5A fuse (F400), and goes to the RF fi nal am-
plifi er, AVR ICs (IC400, IC403), and Control unit (X53-426).
In the control unit, +B is connected to the DC/DC (IC407),
AVR ICs (IC411, IC708, IC416), and voltage detector IC
(IC414). The voltage detector watches the battery voltage.
If the battery voltage is 5.6V or higher, the detector outputs
High. While the output of IC414 is High, IC416 and Q409
provide 3.1V (31BU) to the backup-section.
When the VOL SW is turned on, SB1 becomes high (bat-
tery voltage). The DC/DC (IC407) operates if both SB1 and
the output of the detector are high. IC407 outputs 3.8V and
it activates IC404 (33M), IC717 (15M), and IC406 (33A). As a
result, the ASIC and DSP operate.
The SBC signal becomes High after the ASIC operates,
IC708 (5A), Q403 on the Control unit (SB2) and Q403 on the
TX-RX unit (SB3) are turned on. IC402 and IC403 operate by
turning on these AVR ICs and FET switches.
The 5UC signal becomes High when an option is in-
stalled on the universal connector. Then IC411 (50U) oper-
ates.
When the /SAVE signal becomes High, IC400 (50C)
operates. The output of IC400 is connected to three FET
switches (Q401, Q402, Q405). When the SBC signal be-
comes High, IC403 (33C) operates. The FET switches are
controlled by the ASIC. Q405 (50T) is turned on in transmit
mode. Q401 (50R) and Q402 (50IF) are turned on in receive
mode.
When the VOL SW is turned off, the /PSW signal be-
comes Low. After detecting the /PSW signal, the ASIC
changes the SBC signal to Low. Then the power supplies
except IC416 (31BU) stop.
CIRCUIT DESCRIPTION /
电路说明
6-6. DSP
D S P 电路由 D S P ( I C102) 组成,可处理基带信号。D S P 在
18.432M H z 的外部时钟上运行 ( 与 I C108 相同 ),I / O 部分以
3.3V 运行,核心部分以 1.5V 运行。DSP 执行以下处理 :
• 4 级 FSK 处理
• 模拟 FM 预加重 / 去加重
• 音频编解码器和调制 / 解调之间的声码器处理
• CAI 处理,例如纠错编码
• QT/DQT 编码 / 解码
• LTR 编码 / 解码
• DTMF 编码 / 解码
• MSK 编码 / 解码
• 2 音编码 / 解码
• 压缩器 / 扩展器处理
• 语音扰频器处理
• 发射 / 接收音频滤波处理
• 麦克风放大器 AGC 处理
• 音频静音处理
• 调制电平处理
7. 电源电路
电池电压 (+B) 从 TX/RX 单元 (X57) 上的电池端子提供。电
池电压通过 2.5A 保险丝 ( F400),进入 R F 末级放大器,A V R
IC(IC400,IC403) 和控制单元 (X53-426)。
在 控 制 单 元 中,+ B 被 连 接 到 D C / D C ( I C407),A V R
IC(IC411,IC708,IC416) 和电压检测器 IC(IC414)。电压检测
器观测电池电压。如果电池电压为 5.6V 或更高,则检测器
输出高。I C414 的输出高时,I C416 和 Q409 为后备部分提供
3.1V(31BU)。
VOL SW 打开时,SB1 变高 ( 电池电压 )。如果 SB1 和检测器
的输出都很高,DC/DC(IC407) 将会运行。IC407 输出 3.8V 并
激活 IC404(33M),IC717(15M) 和 IC406(33A)。从而使 ASIC
和 DSP 运行。
S B C 信 号 在 A S I C 运 行 后 变 高, 控 制 单 元 ( S B2) 上 的
I C708(5A ),Q403 和 T X - R X 单 元 ( S B3) 上 的 Q403 打 开。
IC402 和 IC403 通过打开这些 AVR IC 和 FET 开关运行。
通 用 连 接 器 上 装 有 选 购 件 时,5U C 信 号 变 高。 此 时
IC411(50U) 运行。
/ S A V E 信 号 变 高 时,I C400(50C ) 运 行。I C400 的 输 出 连
接 到 三 个 F E T 开 关 ( Q401, Q402, Q405)。S B C 信 号 变 高 时,
I C403(33C ) 运行。F E T 开关由 A S I C 控制。发射模式中打开
Q405(50T)。接收模式中打开 Q401(50R) 和 Q402(50IF)。
V O L S W 关闭时,/ P S W 信号变低。检测 / P S W 信号之后,
ASIC 将 SBC 信号改为低。 随后除 IC416(31BU) 以外的供电停止。
NX-200
39

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents