Sony SWF-BR100 Service Manual page 26

Table of Contents

Advertisement

SWF-BR100
• IC Pin Function Description
MAIN BOARD IC111 R5F3650ECDFB (SYSTEM CONTROLLER)
Pin No.
Pin Name
1 to 5
-
6
BYTE
7
CNVSS
8, 9
-
10
!RESET!
11
XOUT
12
VSS
13
XIN
14
VCC3.3V
15
CEC
16
-
17
AC_CUT
18
DC_DET
19
-
20
SCL5
21
-
22
SDA5
23, 24
-
25
PCON2 (1.8V)
26
PCON1 (3.3V)
27
SCL2
28
SDA2
29
SDA1
30
SCL1
31
CLK1
32
!RTS1!
33
DAMP_SCDT
34
-
35
DAMP_SHIFT
36
-
37
PCON_PVDD
38
DRIVER_RST (EN)
39
!HOLD!
40
DAMP_INIT
41
DAMP_OVF
42
DAMP_LATCH
43
DAMP_SMUTE
44
WR
45
MC_TXD7
46
MC_RXD7
47
MC_CLK7
48
MC_RTS7
49 to 55
-
56
LED_GREEN
57
LED_RED
58, 59
-
60
VCC3.3V
61
-
62
VSS
63
-
64
PVDD_SD_EN
65
DRIVER_SD
66
!INT6!
67
WS_F_DET (82)
68
WS_DET (82)
26
I/O
O
Not used
I
External data bus width selection signal input terminal
I
Processor mode selection signal input terminal
O
Not used
System reset signal input from the reset signal generator
I
For several hundreds msec. after the power supply rises, "L" is input, then it change to "H"
O
System clock output terminal (8 MHz)
-
Ground terminal
I
System clock input terminal (8 MHz)
-
Power supply terminal (+3.3V)
O
Not used
O
Not used
I
AC cut detection signal input terminal
I
Speaker DC detection signal input terminal
O
Not used
O
Not used
O
Not used
O
Not used
O
Not used
O
Power on/off control signal output terminal
O
Power on/off control signal output terminal
O
Not used
O
Not used
O
Transmit data output terminal for fl ash writing
I
Receive data input terminal for fl ash writing
O
Serial data transfer clock signal output terminal for fl ash writing
O
Return to send signal output terminal for fl ash writing
O
Serial data output to the stream processor
O
Not used
O
Clock signal output to the stream processor
O
Not used
O
Power on/off control signal output terminal
O
Reset signal output to the power amplifi er
O
Not used
O
Reset signal output to the stream processor
I
Overfl ow detection signal input from the stream processor
O
Serial data latch pulse signal output to the stream processor
O
Soft muting on/off control signal output to the stream processor
O
Not used
O
Not used
O
Not used
O
Not used
O
Not used
O
Not used
O
LED drive signal output terminal for on/standby indicator (green)
O
LED drive signal output terminal for on/standby indicator (red)
O
Not used
-
Power supply terminal (+3.3V)
O
Not used
-
Ground terminal
O
Not used
O
Shutdown signal output terminal
Shutdown signal input from the stream processor
I
Power detection signal input terminal
O
Not used
I
S-AIR frequency detection signal input terminal
I
S-AIR detection signal input terminal
Description
Fixed at "L" in this unit
"L": reset
"L": AC cut is detected
"L": speaker DC is detected
"H": power on
"H": power on
"H": power on
"L": reset
"L": reset
"L": overfl ow is detected
"H": LED on
"L": shutdown
"L": shutdown
"L": power is detected
Fixed at "H" in this unit
Fixed at "L" in this unit
"L": muting on
"H": LED on

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents