Installing the Device
2.1.2 Mounting the Device to a Rack
2.
3.
4.
10
Insert the device into rack mount adapter and use the screws to secure it.
Note
The device can be installed with the communication ports facing the front or
rear of the rack, depending on the desired orientation.
1 1
Rack Mount Adapter
1
Screw
2
Figure 2.3
Rack Mounting
Insert the rack mount adapter and device assembly into the rack.
Note
Since heat within the device is channelled to the enclosure, it is recommended
that 1 rack-unit of space, or 44 mm (1.75 in), be kept empty above the device.
This allows a small amount of convectional airflow.
Forced airflow is not required. However, any increase in airflow will result in a
reduction of ambient temperature and improve the long-term reliability of all
equipment mounted in the rack space.
Secure the adapter to the rack using the supplied hardware.