2. Distributor type MULTI F DX (1 phase)
2.4 Combination table
The individual indoor unit capacity can be calculated as follows depending on the total connected capacity of all indoor units.
Individual indoor unit
combinational capacity
[Q
]
idu(combi)
Example)
• Outdoor unit model : A7UW40GFA0 [FM40AH UO2]
• Total indoor units combination : 7k + 7k + 7k + 7k + 9k + 9k = 46k
• Each indoor unit combinational capacity?
- Q
odu(rated)
∴ Q
idu(combi)
Models : A7UW40GFA0 [FM40AH UO2]
[Cooling capacity]
Total indoor unit
capacity
(kBtu/h)
Btu/h
16
9,600
18
10,800
19
11,400
21
12,600
23
13,800
24
14,400
25
15,000
26
15,600
27
16,200
28
16,800
29
17,400
30
18,000
31
18,600
32
19,200
33
19,800
34
20,400
35
21,000
36
21,600
37
22,200
38
22,800
39
22,920
40
22,920
41
22,920
42
22,920
43
22,920
44
22,920
45
22,920
46
22,920
47
22,920
48
22,920
49
22,920
50
22,920
51
22,920
52
22,920
Note :
1. Cooling Capacity is based on : indoor temp.27°C DB, 19°C WB
; outdoor temp. 35°C DB, 24°C WB
2. Heating Capacity is based on : indoor temp.20°C DB, 15°C WB
; outdoor temp. 7°C DB, 6°C WB
4 _ Heat pump
50Hz/R410A
Outdoor unit rated capacity
=
[Q
]
odu(rated)
: 11.2kW, Q
: 46 k (Btu/h)
idu(rated)
7
: [7k] = 11.2kW x ––– = 1.70kW
46
Cooling capacity
Min
Rated
kW
Btu/h
2.8
16,000
3.2
18,000
3.3
19,000
3.7
21,000
4.0
23,000
4.2
24,000
4.4
25,000
4.6
26,000
4.7
27,000
4.9
28,000
5.1
29,000
5.3
30,000
5.5
31,000
5.6
32,000
5.8
33,000
6.0
34,000
6.2
35,000
6.3
36,000
6.5
37,000
6.7
38,000
6.7
38,200
6.7
38,200
6.7
38,200
6.7
38,200
6.7
38,200
6.7
38,200
6.7
38,200
6.7
38,200
6.7
38,200
6.7
38,200
6.7
38,200
6.7
38,200
6.7
38,200
6.7
38,200
3. The rated capacities above show the rise in the total indoor unit capacity when operating frequency is
constant.
Values for changes in capacity are fixed after accounting for variations in operating frequency and should
be used as reference values.
4. Total capacity index of indoor unit should be within 16~52 kBtu/h(40%~130%)
5. At least two indoor units should be connected.
Individual indoor unit rated capacity [Q
x –––––––––––––––––––––––––––––––––––––––––––
Total connected indoor unit rated capacity [Q
Q
: [9k] = 11.2kW x –––– = 2.19kW
idu(combi)
Max
kW
Btu/h
kW
4.7
19,200
5.6
5.3
21,600
6.3
5.6
22,800
6.7
6.2
25,200
7.4
6.7
27,600
8.1
7.0
28,800
8.4
7.3
30,000
8.8
7.6
31,200
9.1
7.9
32,400
9.5
8.2
33,600
9.8
8.5
34,800
10.2
8.8
36,000
10.6
9.1
37,200
10.9
9.4
38,400
11.3
9.7
39,600
11.6
10.0
40,800
12.0
10.3
42,000
12.3
10.6
43,200
12.7
10.8
44,400
13.0
11.1
45,600
13.4
11.2
46,000
13.5
11.2
46,000
13.5
11.2
46,000
13.5
11.2
46,000
13.5
11.2
46,000
13.5
11.2
46,000
13.5
11.2
46,000
13.5
11.2
46,000
13.5
11.2
46,000
13.5
11.2
46,000
13.5
11.2
46,000
13.5
11.2
46,000
13.5
11.2
46,000
13.5
11.2
46,000
13.5
]
idu(rated)
]
idu(rated)
9
46
Input (W)
Min
Rated
Max
780
1,120
1,703
800
1,260
1,915
825
1,330
2,022
911
1,470
2,235
998
1,610
2,447
1,042
1,680
2,554
1,085
1,750
2,660
1,128
1,820
2,767
1,172
1,890
2,873
1,215
1,960
2,979
1,259
2,030
3,086
1,302
2,100
3,192
1,345
2,170
3,299
1,389
2,240
3,405
1,432
2,310
3,512
1,476
2,380
3,618
1,519
2,450
3,724
1,562
2,520
3,831
1,606
2,590
3,937
1,649
2,660
4,044
1,693
2,730
4,150
1,693
2,730
4,150
1,693
2,730
4,150
1,693
2,730
4,150
1,693
2,730
4,150
1,693
2,730
4,150
1,693
2,730
4,150
1,693
2,730
4,150
1,693
2,730
4,150
1,693
2,730
4,150
1,693
2,730
4,150
1,693
2,730
4,150
1,693
2,730
4,150
1,693
2,730
4,150