Line
Function
850
I
Floor curing function
- Off : Early interruption of the current programme, programme inactive
- Functional heating
- Curing heating
- Functional heating + curing heating
- Curing heating + functional heating
- Manually
Manual mode enables you to programme your own concrete slab drying time.The function ends automatically after
25 days.
851
I
Floor curing setp manually
(if line 850 = manual)
This function enables you to set the custom concrete slab drying temperature. This temperature remains fixed.
The concrete slab-drying programme stops automatically after running for 25 days.
856
I
Floor curing day current
857
I
Days complete.current
900
S
Operating mode changeover
Operating mode at end of concrete slab drying period
55
50
45
40
35
30
25
20
0
1
5
7
X
Functional
heating
1
Functional heating + Curing heating
figure 15 - Diagram of the concrete slab drying programmes
Installation and operating manual "1395 - EN"
(figure
15)
1
5
10
Curing heating
Setting range or display
0... 95 °C
0... 32
0... 32
None, Protection mode,
Reduced, Comfort, Automatic
15
18
Day
25
Setting
Basic setting
increment
1 °C
1
" Please
comply
with
standards and instructions
of the manufacturer of the
building! A good performance
of this function is only possible
with an installation correctly
implemented
(hydraulic,
electricity and adjustments)!
This function can be stopped
by anticipation when setting
the adjustment on "Stop"
Control Box
Off
25 °C
Protection
mode
the
- 19 -