Mitsubishi Electric -MR-CV User Manual page 99

Power regeneration converter unit
Table of Contents

Advertisement

■Techniques for noises radiated by the converter unit/drive unit that cause peripheral
equipment to malfunction
Noises produced by the converter unit/drive unit are classified into those radiated from the cables connected to the converter
unit/drive unit and its main circuits (input/output), those induced electromagnetically or statically by the signal cables of the
peripheral equipment located near the main circuit cables, and those transmitted through the power supply cables.
Noise produced by the converter
unit/drive unit
(7)
Receiver
Instrument
Noises transmitted
in the air
Magnetic induction
Routes (4) and (5)
noise
Static induction
Route (6)
noise
Noise transmitted
through electric channels
(5)
(7)
(2)
(1)
Converter unit/
Drive unit
(3)
(6)
(4)
M
Servo motor
Noise radiated directly from the converter
unit/drive unit
Noise radiated from the power cable
Noise radiated from servo motor cable
Noise transmitted through power cable
Noise sneaking from grounding cable due to leakage current
(7)
Sensor
power supply
(2)
(8)
Sensor
(3)
10 OPTIONS AND PERIPHERAL EQUIPMENT
10.5 Noise reduction techniques
Route (1)
Route (2)
Route (3)
Route (7)
Route (8)
97