MXZ-HA
MXZ SERIES - MULTI SPLIT - DC Inverter/Heat Pump
230V
Breaker
DIAMETER
SIZE
Liquid mm
(inches)
MXZ-2HA40VF
MXZ-2HA50VF
Vedi tabella
MXZ-3HA50VF
External piping diameter
CONNECTIONS
Liquid
Unit A
Liquid
Unit B
Liquid
Unit C
Example of total additional charge calculation
Formula
Precharge lenght (m)] x additional charge (g/m)
Example
Outdoor unit = MXZ-3HA50VA
Total pipes lenght (inlet piping only) = 20 m
Lenght with additional charge (as tab) = 7 m
Additional charge = 20 g/m
Calculation: ∆W(g) = [20 - 7] x 20 = 260 g
L
N
MXZ-HA_VF
EXTERNAL PIPING
Gas mm
Max
Max
(inches)
Height
Lenght*
15
20/30
15
20/30
15
25/50
MXZ-2HA
6,35 (1/4")
Gas
9,52 (3/8")
6,35 (1/4")
Gas
9,52 (3/8")
-
Gas
-
∆W(g) = [Lenght of pipes (m) -
S1
S2
S3
S1
S2
S3
S1
S2
S3
REFRIGERANT CHARGE
Precharge
Max
Precharge
lenght
Pipe Bends
Kg*
mt.
20/20
0,9
30
20/30
0,9
30
25/50
1,4
7
MXZ-3HA
6,35 (1/4")
9,52 (3/8")
6,35 (1/4")
9,52 (3/8")
6,35 (1/4")
9,52 (3/8")
MIN AREA according to standard CEI EN 60335-2-40 ED6 R32 - HUMAN COMFORT
UNIT
INDOOR
MXZ-2HA40VF
MXZ-2HA50VF
MXZ-3HA50VF
MITSUBISHI ELECTRIC / MXZ SERIES
S1
S2
S3
S1
S2
S3
S1
S2
S3
Additional
tonCO
eq
tonCO
charge
2
precharge*
max charge*
g/mt
-
0,61
0,61
-
0,61
0,61
20
0,95
1,53
Max charge (kg)
0,90
0,90
2,26
UNIT A
UNIT B
UNIT C
BREAKER
eq
2
15 A
15 A
25 A
Min Area (m²)
0,77
0,77
4,83