Download Print this page

Mitsubishi Electric M Series Installation Manual page 43

Hide thumbs Also See for M Series:

Advertisement

SUZ-SM / PUZ-SM
S/P SERIES - OUTDOOR UNIT - Smart
230V
Three-phase connection
DIAMETER
SIZE
MODEL
Liquid mm
(inches)
71
SUZ-SM
9,52 (3/8")
100
9,52 (3/8")
125
PUZ-SM
9,52 (3/8")
140
9,52 (3/8")
Exemple of total additional charge calculation
Formula
Precharge lenght (m)] x additional charge (g/m)
Example
Outdoor unit = PUZ-SM125VA
Total pipes lenght (inlet piping only) = 35 m
Lenght with additional charge (as tab) = 30 m
Additional charge = 40 g/m
Calculation: ∆W(g) = [35 - 30] x 20 = 100 g
L
N
Breaker
SUZ / PUZ-SM
L1
L2
380V
L3
N
Breaker
EXTERNAL PIPING
Gas mm
Max
Max
(inches)
Height
Lenght*
Pipe Bends
15,88 (5/8")
30
30
15,88 (5/8")
30
30
15,88 (5/8")
30
40
15,88 (5/8")
30
40
∆W(g) = [Lenght of pipes (m) -
S1
S2
S3
REFRIGERANT CHARGE
Precharge
Max
Precharge
lenght
Kg*
mt.
10
1,45
7
15
3,10
15
3,60
30
15
3,60
MIN AREA according to standard CEI EN 60335-2-40 ED6 R32 - HUMAN COMFORT
UNIT
INDOOR
WALL MOUNTED
CEILING - DUCTED
MITSUBISHI ELECTRIC / P SERIES R32
S1
S2
S3
Indoor unit
Additional
tonCO
eq
tonCO
eq
charge
2
2
precharge*
max charge*
g/mt
0,98
1,60
2,09
2,09
40
2,43
3,51
2,43
3,51
Max charge (kg)
OUTDOOR
71
2,37
100
3,10
125
4,00
140
4,00
71
2,37
100
3,10
125
4,00
140
4,00
ELECTRICAL DATA
Operating
current
Breaker
max
1
25 A
1 / 3
32 A / 16 A
1 / 3
32 A / 16 A
1 / 3
40 A / 16 A
Min Area (m²)
5,31
9,09
15,13
15,13
3,56
6,08
10,13
10,13
41

Advertisement

loading