IMPORTANT SERVICE NOTES (XL-30H FOR U.K. ONLY)
Before returning the unit to the customer after completion of a
repair or adjustment it is necessary for the following withstand
voltage test to be applied to ensure the unit is safe for the
customer to use.
Setting of Withstanding Voltage Tester and set.
Set name
Withstanding Voltage Tester
Test voltage
Set time
Set current(Cutoff current)
Unit
Judgment
OK: The "GOOD" lamp lights.
NG: The "NG" lamp lights and the buzzer sounds.
The voltage selector is located on the rear panel of the unit. If adjustment is necessary, use a screwdriver in order to turn the selector
in either direction until the correct voltage figure is displayed in the window.
AC POWER SUPPLY CORD AND AC PLUG ADAPTOR (FOR XL-30W)
QACCA0001SJ00
QACCB0001SJ00
QACCE0001SJ00
QACCL0002AW00
All manuals and user guides at all-guides.com
set value
4,240 VPEAK
3,000 VRMS
6 secs
4 mA
VOLTAGE SELECTION (FOR XL-30W)
– 3 –
WITHSTANDING
VOLTAGE TESTER
AC
OUT
SHORT-CIRCUT
AC POWER
SUPPLY CORD
QPLGA0253AFZZ
QPLGA0250AFZZ
XL-30H/30W
PROBE
UNIT
CONNECT THE PROBE
TO GND OF CHASSIS
SCREW TERMINAL