MECHANISM SECTION
• Driving Force Check
Torque Meter
Play: TW-2412
• Torque Check
Torque Meter
Play: TW-2111
Fast forward: TW-2231
Rewind: TW-2231
• Tape Speed
Adjusting
Test Tape
Point
MTT-111
Variable
resistor in
motor.(M901)
TAPE MECHANISM
Figure 13-1 ADJUSTMENT POINT
TUNER SECTION
fL: Low-renge frequency
fH: High-renge frequency
• AM IF/RF (For XL-30H)
Signal generator: 400 Hz, 30%, AM modulated
Display
Frequency Frequency
IF
450 kHz
1,620 kHz
AM Band
522 kHz
Coverage
AM
990 kHz
990 kHz
Tracking
• AM IF/RF (For XL-30W)
Signal generator: 400 Hz, 30%, AM modulated
Test Stage Frequency
Frequency
Display
AM IF
450 kHz
1,602 kHz
AM Band
531 kHz
Coverage
AM Tracking 990 kHz
990 kHz
*1. Input: Antenna, Output: Speaker Terminal
*2. Input: Input is not connected,
Span selectors are to be 9 kHz (AM), 50 kHz (FM).
• Check FM VT (XL-30H/30W)
Signal generator: 1 kHz, 40 kHz dev., FM modulated
Frequency
Display
87.5 MHz
87.5 MHz
108 MHz
108 MHz
All manuals and user guides at all-guides.com

ADJUSTMENT

Specified Value
Over 80 g
Specified Value
30 to 60 g. cm
55 to 140 g.cm
55 to 140 g.cm
Specified
Instrument
Value
Connection
3,000 ±
Headphone
90 Hz
terminal
M901
Tape
Motor
Variable
resistor
in motor
Setting/
Instrument
Adjusting
Connection
Parts
T351
*1
(fL): T306
*2
1.1 ± 0.1 V
T302
*1
Setting/
Instrument
Adjusting
Connection
Parts
T351
*1
(fL): T306
*2
1.1 ± 0.1 V
T302
*1
Output: TP301
Check Point
Instrument
Connection
3.4 V ± 1.0 V
TP301
7.8 V ± 1.0 V
TP301
• FM Mute Level (For XL-30W)
Signal generator: 1 kHz, 40 kHz dev., FM modulated
Display
Frequency
98.00 MHz
98.00 MHz
(25 dBµV)
*1. Adjust so that an output signal appears.
• FM Mute Level (For XL-30H)
Signal generator: 1 kHz, 40 kHz dev., FM modulated
Display
Frequency
98.00 MHz
98.00 MHz
(30 dBµV)
*1. Adjust so that an output signal appears.
• FM Detection (XL-30H/W)
Signal generator: 10.7 MHz, FM sweep generator
Test
Frequency
Frequency
Stage
FM IF
10.7 MHz
98.00 MHz
• FM RF (XL-30H/W)
Signal generator: 1 kHz, 75 kHz dev., FM modulated
Test Stage Frequency
FM Band
Coverage
FM RF
98.00 MHz
(10~30 dB)
*1. Input: Antenna, Output: TP301
*2. Input: Antenna, Output: Speaker Terminal
MAIN PWB
FM Mute
Level
AM IF
VR351
T351
CF352
TP301
IC303
R336
T306
AM Band
Coverage fL
Figure 13-2 ADJUSTMENT POINTS
– 13 –
XL-30H/30W
Adjusting
Instrument
Parts
Connection
VR351*1
Input: SO301
Output: Speaker
Terminal
Adjusting
Instrument
Parts
Connection
VR351*1
Input: CNP301
Output: Speaker
Terminal
Setting/
Instrument
Display
Adjusting
Connection
Parts
T304(Turn
Input: Pin 1 of
the core of IC301
T304 fully
counter-
clockwise).
Frequency
Setting/
Instrument
Display
Adjusting
Connection
Parts
87.50 MHz
(fL): L303
*1
3.4 ± 0.1 V
98.00 MHz
L302
*2
IC302
SO301
ANTENNA
SOCKET
(XL-30W
Only)
FM Band
Coverage fL
L303
9
T304
IC301
FM IF
BF301
1
FM RF
L302
CNP301
ANTENNA
T302
SOCKET
AM
Tracking

Hide quick links: