Electric Characteristics - LG R5TT20F-SA1 Engineering Product Data Book

Heat pump water heater
Table of Contents

Advertisement

Heat Pump Water Heater

Electric Characteristics

11.
R5TT20F-SA1 / WH20S.F5
Model
Indoor Unit
R5TT20F-SA1 / WH20FS.F5
Note
1. Voltage range
Voltage supplied to the unit terminals should be within the minimum and maximum range.
2. Maximum allowable voltage unbalance between phase is 2 %.
3. Select wire spec. based on the larger value of MCA.
4. RLA is measured during each individual compressor test condition.
5. OFM is measured as the outdoor unit test condition.
6. Recommended circuit breaker is ELCB. (Earth Leakage Circuit Breaker)
15
- 50 Hz (R134a)
Unit
Voltage Range
Type
Hz Voltage
Min : 195
Inverter
50
230
Max : 265
Power
Compressor
MCA
MOP
MSC
Cool
15.1
15.0
-
-
MCA : Minimum Circuit Amperes (A)
MOP : Maximum Rating Over Current Protective Device (A)
MSC : Maximum Starting Current (A)
RLA : Rated Load Amperes (A)
FM : Fan Motor
W : Fan Motor Rated Output (W)
FLA : Full Load Amperes (A)
FM
RLA
W
FLA
Heat
3.3
43
0.22