Heat Pump Water Heater

Electric Characteristics

11.
R5TT20F-SA0
Model
Indoor Unit
R5TT20F-SA0
Note
1. Voltage range
Voltage supplied to the unit terminals should be within the minimum and maximum range.
2. Maximum allowable voltage unbalance between phase is 2 %.
3. Select wire spec. based on the larger value of MCA.
4. RLA is measured during each individual compressor test condition.
5. OFM is measured as the outdoor unit test condition.
6. Recommended circuit breaker is ELCB. (Earth Leakage Circuit Breaker)
15
- 60 Hz (R134a)
Unit
Type
Hz Voltage
60 208 / 240
Inverter
※ NSF372 will be certified by CSA unitl May 2021
Power
Voltage Range
MCA
MOP
Min : 187
30.1
30.0
Max : 276
MCA : Minimum Circuit Amperes (A)
MOP : Maximum Rating Over Current Protective Device (A)
MSC : Maximum Starting Current (A)
RLA : Rated Load Amperes (A)
FM : Fan Motor
W : Fan Motor Rated Output (W)
FLA : Full Load Amperes (A)
Compressor
RLA
MSC
W
Cool
Heat
-
-
3.3
43
FM
FLA
0.22