Download Print this page
Sealey SDH30.V2 Quick Start Manual

Sealey SDH30.V2 Quick Start Manual

Industrial dehumidifiers 30l

Advertisement

Quick Links

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions,
and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
Refer to
Do not cover
Instruction
manual
1. SAFETY
1.1.
ELECTRICAL SAFETY
WARNING! It is the user's responsibility to check the following:
Check all electrical equipment and appliances to ensure that they are safe before using. Inspect power supply leads, plugs and all
electrical connections for wear and damage. Sealey recommend that an RCD (Residual Current Device) is used with all
electrical products. You may obtain an RCD by contacting your local Sealey stockist.
If the product is used in the course of business duties, it must be maintained in a safe condition and routinely PAT (Portable Appliance
Test) tested.
Electrical safety information, it is important that the following information is read and understood.
1.1.1.
Ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply.
1.1.2.
Regularly inspect power supply cables and plugs for wear or damage and check all connections to ensure that they are secure.
1.1.3.
Important: Ensure that the voltage rating on the appliance suits the power supply to be used and that the plug is fitted with the correct
fuse - see fuse rating in these instructions.
DO NOT pull or carry the appliance by the power cable.
8
DO NOT pull the plug from the socket by the cable.
8
DO NOT use worn or damaged cables, plugs or connectors. Ensure that any faulty item is repaired or
8
replaced immediately by a qualified electrician.
1.1.4.
This product is fitted with a BS1363/A 13 Amp 3 pin plug.
If the cable or plug is damaged during use, switch the electricity supply and remove from use.
Ensure that repairs are carried out by a qualified electrician.
Replace a damaged plug with a BS1363/A 13 Amp 3 pin plug. If in doubt contact a qualified electrician.
a) Connect the GREEN/YELLOW earth wire to the earth terminal 'E'.
b) Connect the BROWN live wire to the live terminal 'L'.
c) Connect the BLUE neutral wire to the neutral terminal 'N'.
Ensure that the cable outer sheath extends inside the cable restraint and that the restraint is tight.
Sealey recommend that repairs are carried out by a qualified electrician.
1.2.
GENERAL SAFETY
Check that the dehumidifier is in sound condition and good working order. Take immediate action to repair or replace damaged parts.
9
Use recommended parts only. Unauthorised parts may be dangerous and will invalidate the warranty.
9
NOTE: SDH30.V2 is filled with R290.
Appliances shall be installed, operated and stored in a room with a working space of: refer to Specification section 3.
9
DO NOT perforate any of the components in the refrigerant circuit. Refrigerant gas may be odourless.
8
DO NOT attempt any repairs / maintenance unless suitably qualified.
8
DO NOT stand or place any object less than 10cm from the front or rear of the unit.
DO NOT obstruct the air intakes or outlets of the dehumidifier.
8
DO NOT place any object into the outlets - the unit has a fan running at high speed, contact with this will cause injury.
8
DO NOT operate the dehumidifier when you are tired or under the influence of alcohol, drugs or intoxicating medication.
8
DO NOT switch the dehumidifier off by disconnecting it from the mains. ALWAYS switch to the "OFF" position first.
8
DO NOT remove the float lever from the water collection tank.
8
DO NOT connect or disconnect the plug from the mains with wet hands.
8
Always discard the water from the collection tank, DO NOT use it for any other purpose.
9
Place the dehumidifier on a level and stable surface.
9
DO NOT use the dehumidifier at ambient temperatures below 5°C.
8
DO NOT use the dehumidifier outside.
8
When using continuous draining, make sure that the drain hose is positioned correctly.
9
Ensure that heating appliances are not exposed to the flow of air from the dehumidifier.
9
Before attempting to move the dehumidifier, empty the contents of the collection tank.
9
Switch off and disconnect it from the mains before attempting any cleaning or other maintenance work.
9
Ensure that the dehumidifier is correctly turned off when not in use, and stored in a safe, dry area, out of reach of children.
9
This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental
capabilities or lack of experience or knowledge if they have been given supervision or instruction concerning use of the appliance in a
safe way and understand the hazards involved. Children shall not play with the appliance.
© Jack Sealey Limited
INDUSTRIAL DEHUMIDIFIERS 30L
MODEL NO:
Indoor use only
Caution:
Risk of fire
Original Language Version
SDH30.V2
Recommended fuse rating
13 Amp
SDH30.V2 Issue 1 30/11/20

Advertisement

loading

Summary of Contents for Sealey SDH30.V2

  • Page 1 SDH30.V2 MODEL NO: Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble free performance. IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED.
  • Page 2 The unit will not restart until the water collection tank has been emptied. 4.3.2. Open the door and remove water collection tank from the dehumidifier by pulling it gently outwards by holding the sides of the tank (fig.3). SDH30.V2 Issue 1 30/11/20 Original Language Version © Jack Sealey Limited...
  • Page 3 Doors or windows open Close openings Refrigerant leak Contact Sealey stockist Water leaking from unit Dehumidifier is not level Adjust position of dehumidifier Reservoir float not shutting down unit Contact Sealey stockist Original Language Version © Jack Sealey Limited SDH30.V2 Issue 1 30/11/20...
  • Page 4 Important: No Liability is accepted for incorrect use of this product. Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim. Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR 01284 757500 01284 703534 sales@sealey.co.uk...

This manual is also suitable for:

Sdh30