Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these
instructions, and properly maintained, give you years of trouble free performance.
IMP
P
OR
R TA
TANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
TH
H E
P
P
RO
O DUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PE
E
RS
S ON
N AL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
Refer to
Do not cover
instructions
1. SAFETY
1.1.
ELECTRICAL SAFETY
WARNING! It is the responsibility of the owner and the operator to read, understand and comply with the following:
You must check all electrical products, before use, to ensure that they are safe. You must inspect power cables, plugs, sockets
and any other connectors for wear or damage. You must ensure that the risk of electric shock is minimised by the installation of
appropriate safety devices. A Residual Current Circuit Breaker (RCCB) should be incorporated in the main distribution board. You
must also read and understand the following instructions concerning electrical safety.
Ensure that cables are always protected against short circuit and overload.
Regularly inspect power supply cables and plugs for wear or damage and check all connections
to ensure that none are loose.
Ensure that the voltage marked on the appliance matches the power supply to be
used and that the plug is fi tted with the correct fuse - see fuse rating at right.
DO NOT use worn or damaged cables, plugs or connectors. Have any faulty item repaired or
replaced immediately by a competent electrician.
It is recommended that this device is wired directly to a fused isolator switch. If, however, a plug
is fi tted, the following applies:
Fit a new plug according to the following instructions (UK only).
a) Connect the GREEN/YELLOW earth wire to the earth terminal 'E'.
b) Connect the BROWN live wire to the live terminal 'L'.
c) Connect the BLUE neutral wire to the neutral terminal 'N'.
d) After wiring, check that there are no bare wires, that all wires have been correctly connected,
that the cable restraint is tight.
1.2.
GENERAL SAFETY
Check that the dehumidifi er is in sound condition and good working order. Take immediate action to repair or replace damaged
parts.
Use recommended parts only. Unauthorised parts may be dangerous and will invalidate the warranty.
DO NOT stand or place any object less than 100cm from the front, or 50cm from the rear or sides of the unit.
DO NOT obstruct the air intakes or outlets of the dehumidifier.
DO NOT place any object into the outlets.
DO NOT operate the dehumidifier when you are tired or under the influence of alcohol, drugs or intoxicating medication.
DO NOT switch the dehumidifier off by disconnecting it from the mains. ALWAYS switch to the "OFF" position first.
DO NOT connect or disconnect the plug from the mains with wet hands.
Always discard the water from the collection tank, DO NOT use it for any other purpose.
Place the dehumidifi er on a level and stable surface.
DO NOT use the dehumidifi er at ambient temperatures below 5°C.
DO NOT use the dehumidifi er outside.
Ensure that heating appliances are not exposed to the flow of air from the dehumidifier.
Switch off and disconnect it from the mains before attempting any cleaning or other maintenance work.
Ensure that the dehumidifier is correctly turned off when not in use, and stored in a safe, dry area, out of reach of children.
This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental
capabilities or lack of experience or knowledge if they have been given supervision or instruction concerning use of the appliance
in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance
shall not be made by children without supervision.
2. INTRODUCTION
Powerful dehumidifi cation capacity, extracts up to 90 litres of water per day. Removes excess moisture from air, preventing build-up of
mildew and mould. Features auto-defrost function, which activates if the room temperature falls too low. The unit has a 24hr timer function
for delay starting and auto shut-off . Washable air fi lter. Refrigerant is environmentally friendly R290. Features a permanent drain hose for
continuous operation. Mounted on castors for manoeuvrability.
© Jack Sealey Limited
90L INDUSTRIAL DEHUMIDIFIER
SDH90
MODEL NO:
Indoor use
Caution:
only
Risk of fi re
Original Language Version
Recommended fuse rating
13 Amp
SDH90 Issue 1 28/02/22

Advertisement

loading

Summary of Contents for Sealey SDH90

  • Page 1 90L INDUSTRIAL DEHUMIDIFIER SDH90 MODEL NO: Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble free performance. R TA TANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE O DUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED.
  • Page 2 (fi g 1-1) will fl icker and the current set time will be displayed. Use the Increase/ Decrease buttons (fi g 1-10, fi g 1-11) to set the required value to between 0 and 24 hours. After 10 seconds the selected value is set and the Timer OFF led will fl icker. SDH90 Issue 1 28/02/22 Original Language Version...
  • Page 3 Dismantle the front plate to eliminate blockages Coil sensor fault Contact Sealey service centre Fault of humidity & temperature sensor Contact Sealey service centre Error codes Refrigerant leakage Contact Sealey service centre SDH90 Issue 1 28/02/22 Original Language Version © Jack Sealey Limited...
  • Page 4 Important: No Liability is accepted for incorrect use of this product. Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim. Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR 01284 757500 01284 703534 sales@sealey.co.uk...