Waste oil drainer 65ltr air discharge

Advertisement

5. AIR SUPPLY
5.1.
Air Supply
WARNING! Ensure the air supply is clean and does not exceed 0.7bar. Too high an air pressure and unclean air will
5.1.1.
shorten the product life due to excessive wear, and may be dangerous causing damage and/or personal injury.
5.1.2.
Recommended hook-up procedure is shown in fig 1.
5.1.3.
Ensure drainer air valve (or trigger) is in "Off" position before connecting to the air supply.
5.1.4.
You will require an air pressure of 0.7bar.
5.1.5.
Drain the air tank daily. Water in the air line will damage the tool.
5.1.6.
Clean air inlet filter weekly.
5.1.7.
Line pressure should be increased to compensate for unusually long air hoses (over 8 metres). The minimum hose should be 1/4" I.D.
and fittings must have the same inside dimensions.
5.1.8.
Keep hose away from heat, oil and sharp edges.
5.1.9.
Check hose for wear, and make certain that all connections are secure.
fig.1
6. OPERATION
NOTE: Numbers in brackets refer to item numbers on the Parts List diagram.
WARNING! Ensure that you read, understand and apply the safety instructions in Section 1.
IMPORTANT! Dispose of waste oil in accordance with local authority regulations.
IMPORTANT! Never leave drainer with pressure in the reservoir.
6.1.
Draining vehicle
6.1.1.
Position drainer under vehicle, turn rubber nut (8) approximately 1/4 turn anticlockwise and raise oil pan (13) beneath drain plug.
DANGER! DO NOT release clamp (8) when there is pressure in the reservoir as pipe (11) and oil pan (13) will be propelled upward with
force. This could result in damage and/or serious injury.
6.1.2.
Open ball valve (12) and then remove vehicle drain plug.
6.1.3.
When draining is complete lower oil pan (13) before moving drainer.
6.2.
Emptying drainer
6.2.1.
Ensure all ball valves are closed and clamp (8) is tight. Connect air supply at a pressure of 0.7bar to air inlet valve (4).
6.2.2.
Open air inlet valve (4) and allow reservoir to pressurise until safety valve (5) vents. Close air inlet valve (4) and disconnect air supply.
6.2.3.
Place end of drain tube in the waste oil container and then open ball valve (3).
6.2.4.
When all waste oil is displaced from reservoir any remaining air pressure will be lost.
6.2.5.
Always confirm that reservoir pressure is zero before closing valve (3).
ENVIRONMENT PROTECTION
Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to
a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely
unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and dispose of the product and fluids
according to local regulations.
Note: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior
notice.
Important: No Liability is accepted for incorrect use of this product.
Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim.
Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR
01284 757500
© Jack Sealey Limited
01284 703534
sales@sealey.co.uk
Original Language Version
www.sealey.co.uk
AK451DX
Issue 3 (H, F) 25/04/18

Advertisement

loading

This manual is also suitable for:

051713451