(15) Removing and Replacing the Power Cord
1 Remove the turntable.
→ (See "(14) Removing the Turntable".)
2 Remove the power cord from the joint of
the turntable, and then pull out the power
cord from the turntable and bottom panel
to remove it.
→ (Removing and Replacing the Power
Cord)
(16) Removing and Replacing Three Automatic Rotation Position Detection
Sensors
1 Remove the turntable.
→ (See "(14) Removing the Turntable".)
2 Disengage the nine tabs of the three
automatic rotation position detection
sensors under the sensor protection
sticker (clear) on the turntable, and pull
out the three automatic rotation detection
sensors downward to remove them.
3 Remove the connector from each
automatic rotation position detection
sensor (circuit board).
→ (Removing and Replacing the Three
Automatic Rotation Position Detection
Sensors)
<Connector color>
2
White
Black
Blue
2
Turntable
Power cord
2
Power cord
Bottom panel
Sensor protection sticker
2
Turntable
Tab
Tab
Tab
39
Joint
Automatic
rotation position
detection sensor
Automatic
rotation position
Connector
detection sensor
3