Mounting The Fmb Drive; Installing The Mount And Gear Unit - Bosch Rexroth FMS Instructions Manual

Function modules
Table of Contents

Advertisement

20/30
Bosch Rexroth AG
8

Mounting the FMB drive

NOTICE
Risk of excessive torque and rotary speed if limit values are not adhered to!
Avoid tension due to the weight of the motor when mounting the motor!
Damage to the product.
Observe the specified limit values. Technical data and limit values ! catalog.
f
Install the motor in a vertical position.
f
Tightening torques ! 17.1
8.1

Installing the mount and gear unit

Insert the first coupling half (1) into the Tubular Shaft (2) of the end enclosure (8) and tighten the screw (3) to
1.
tightening torque M
in accordance with Table 7 (! Fig. 17). (The journal and Tubular Shaft must be free of grease.)
A2
2.
Attach the second coupling half (4) to the first coupling half.
3.
Install the mount (5) onto the gear unit (7) with four screws (6) using tightening torque M
4.
Vertically attach the gear unit and the mount to the end enclosure (8). Center these via the coupling (4).
5.
Fasten the mount and gear unit on the end enclosure (8) using four screws (9) to tightening torque M
6.
Tighten the clamping screw (10) of the 2nd coupling half (4) using the mount bore (11) to tightening torque M
accordance with Table 7 (! Fig. 17) for clamping on the gear shaft (12).
9
4
8
4.
Fig. 17: Mounting the FMB drive
8
2
1
3
1.
5.+6.
Function modules | R320103174/2018-08
4
2.
4
12
Tabelle 7:
Tightening torque M
11
screws 3 and 10
10
FMB
-080
M6x18-12.9
-110
(! 17.1).
A
.
A
A2
6
5
7
for
A2
(3 / 10)
M
A2
(Nm)
ISO4762
16.5
in
3.