3608870H86/2020-01 | ErgoSpin/CC-ErgoSpin

Troubleshooting

14
Troubleshooting
Failures and information on faults are displayed
in the tightening system and/or its operating
program, e.g. BS350 (ErgoSpin), BS350 CC-ES
(CC-ErgoSpin, until the BS350 Standard with
V2.400 has been introduced).
If you are not able to remedy a defect, please
contact one of the addresses that you can
either find at
http://www.boschrexroth.com
or in section "Service and Sales"
on page 97.
Tab.16: General information
General information
Protection class
Protection class
Interference suppression
Electric connection
Admissible ambient temperature
Admissible storage temperature
Allowed air humidity during operation
Allowed air humidity during storage
Bosch Rexroth AG
15

Technical data

The A-weighted noise pressure level of the
product is typically
65 dB (A). The handarm
vibration is typically lower than 2.5m/s
The accuracy according to VDI/VDE2647
across a range of 6S in
• ESM and ESV systems with straight output
drive is less than ± 3 %,
• ESA and ESV with angle head or offset output
drive is less than ± 4 %,
• CC-ESM and CC-ESV with straight output
drive is less than ± 5 %,
• CC-ESA and CC-ESV with angle head or offset
output drive is less than ± 7 %.
I (protective grounding)
Limit class A according to EN 55011
11-pin round plug
0 °C ... + 40 °C
– 20 °C ... + 70 °C
20–80 %
20 - 90%
91/104
.
2
IP 40