Cleaning Notes; Regular Maintenance Tasks - Bosch Rexroth IndraControl VSP 3 Series Instructions Manual

Table of Contents

Advertisement

Bosch Rexroth AG
Maintenance
NOTICE
Use only copper wire for wiring the connection terminals. Tighten the screws of the
screw terminals with the following torque:
Threads
M2.5
M3
M4
M5
Fig.14-1: Mounting torques
14.2

Cleaning Notes

● Clean the screen at least once a week using an antistatic fabric or a cleansing agent
containing alcohol.
NOTICE
● Do not use any solvents (e. g. diluents)!
● Do not use compressed air, steam jet and high pressure cleaning devices!
14.3

Regular Maintenance Tasks

Include the following measures in the maintenance schedule:
● At least once a year, all plug and terminal connections of the components are to be
checked regarding proper tightness and possible damage.
● Make sure that cables are not broken or crushed.
● Damaged parts must be replaced immediately.
DANGER
The fan impeller is not to be touched with the hands and may not come into contact
with other objects.
32/43
DOK-SUPPL*-VSP*XX.3***-IT01-EN-P
Rexroth IndraControl VSP xx.3 Panel PC
Destruction of screw terminals, insufficient contact
and loss of UL certification if no copper wire is used
or due to wrong tightening torque.
Mounting torques
0.4 Nm
0.7 Nm
1.4 Nm
2.8 Nm
Dissolution of the foil surface as well as the display
seal by solvents or by high pressure cleaning devi‐
ces!
Risk of injury by rotating fan impeller!