Over Flow Error (FE)
Is the water coming in
drawer continuously?
NO
After power off for 10 sec. and power on.
Does the water level over reference line and Is
Or does
not
the water level over reference line and is the water level frequency 26.2Khz ?
YES
Replace the
Main
PCB.
YES
Replace the
not
the water level frequency 26.2Khz ?
* Water level frequency
- Press and Hold
The digits means water level frequency. (10
ex) 241 : Water level frequency = 241 x 10
Check the
If FE is displayed again,
then replace the
If FE is displayed again,
then replace the
25
Inlet Valve
assembly.
'Intensive'
&
'Option(Left)'
NO
Air Chamber
and the
Pressure
Switch.
Main
PCB.
simultaneously.
-1
kHz)
-1
kHz
24.1 kHz
Tube
(clogged).