Sanyo PLC-XE50A Service Manual page 58

Hide thumbs Also See for PLC-XE50A:
Table of Contents

Advertisement

Service Adjustment
Group/
Item Name
Item
Group 256 Fan Lamp Voltage Down Setting
0 Lamp Voltage
1 Lamp Vol Threshold
2 Fan1 Speed Gain
3 Fan2 Speed Gain
4 Fan3 Speed Gain
5 Not used
Group 257 Fan Dimmer Setting
0 Dimmer Average Check Period
1 Dimmer Average
2 Last Voltage Difference
3 Voltate Difference Goal
Group 258 Fan IC Temp for Netowrk model
0 Not used.
1 Not used.
2 Not used.
Group 260 Auto Calibration (Commn) * Auto Calibration
0 Execute Calibration
1 Loop Count
2 Auto Status
3 AutoWait
4 CHECK -Tolelance
Group 261 Auto Calibration (RGB)
0 OFFSET AREA H START
1 OFFSET AREA V START
2 GAIN AREA H START
3 GAIN AREA V START
4 Image AREA H WIDTH
5 Image AREA V HIGHT
6 OFFSET target
7 OFFSET torelance
8 GAIN target
9 GAIN torelance
Group 262 Auto Calibration (CVBS/SVIDEO)
0 Y Image Area Start X
1 Y Image Area Start Y
6 Image Area H Width
7 Image Area V Hight
8 Y Target Level
11 Gain Tolerance
12 Delta Gain
Group 264 Auto Calibration (YCbCr)
0 Y-OFFSET AREA H START
1 Y-OFFSET AREA V START
2 CB - OFFSET AREA H START
3 CB - OFFSET AREA V START
4 CR - OFFSET AREA H START
5 CR - OFFSET AREA V START
6 Y - GAIN AREA H START
7 Y - GAIN AREA V START
Function
Current Lamp Voltage (0.1V)(Read
only)
Threshold to judge Lamp Voltage
Down ( V×10)
Additional Fan Speed of Min at Lamp
Voltage Down (unit: 0.1V)
Dimmer Average measurement Time
(0:10sec, 1:30sec, 2:60sec, 3: 90sec
...10:300 sec)
Dimmer Average Value (Read only)
Read only
Read only
Maximum Execution Times (OFFSET-
>GAIN)
Result of Auto-Calibration (Last
Memory)
Wait Value for each setting
Torelance of OFFSET
Black Level Acquiring Area H-Start
Position
Black Level Acquiring Area V-Start
Position
White Level Acquiring Area H-Start
Position
White Level Acquiring Area V-Start
Position
Black/White Level Acquiring Area
Black/White Level Acquiring Area
Height
Target Value of Black Level Adj.
Torelance of Black Level Adj.
Target Value of White Level Adj.
Torelance of White Level Adj.
Y Acquiring Area H-Start Position
Y Acquiring Area V-Start Position
Image Level Acquiring Area
Image Level Acquiring Area Height
Target Value of Y Level Adj.
Torelance of Level Adj.
Deviation Width of Gain Value
Y - Offset Acquiring Area H-Start
Position
Y - Offset Acquiring Area V-Start
Position
CB - Offset Acquiring Area H-Start
Position
CB - Offset Acquiring Area V-Start
Position
CR - Offset Acquiring Area H-Start
Position
CR - Offset Acquiring Area V-Start
Position
Y
Initial
-
9999
1
-
-
0
10
0
1
2
975
500
25
500
13
9
3
1
238
1
20
200
8
9
217
1
9
925
500
925
500
925
500
50
500
- 58 -
Range Note
0-255
30-90
0-255
0-255
0-255
-
0-10
Executes Auto-Calibration when
0 - 1
changiing the Value (PC White 100%)
1 - 30
0 / 1 / 9
0: OK, 1: Adjusting,9: Error * ReadOnly
1 - 20
1 - 255
0 - 1000
0 - 1000
0 - 1000
0 - 1000
0 - 4095
0 - 4095
0 - 127
1 - 127
0 - 255
1 - 255
0 - 1000
0 - 1000
0 - 4095
0 - 4095
0 - 255
0 - 255
0 - 255
0 - 1000
0 - 1000
0 - 1000 If not used: use Y's value
0 - 1000 If not used: use Y's value
0 - 1000 If not used: use Y's value
0 - 1000 If not used: use Y's value
0 - 1000
0 - 1000