Group/
Item Name
Item
8 CB - GAIN AREA H START
9 CB - GAIN AREA V START
10 CR - GAIN AREA H START
11 CR - GAIN AREA V START
12 Image AREA H WIDTH
13 Image AREA V HIGHT
14 Y - OFFSET TARTGET
15 CB OFFSET TARGET
16 CR OFFSET TARGET
17 Y - GAIN TARGET
18 CB - GAIN TARGET
19 CR - GAIN TARGET
20 OFFSET torelance
21 GAIN torelance
Group 270 CUSTUM (Aspect)
0 Scaler Horizontal
1 Scaler Vertical
2 Connect
3 Position Horizontal
4 Position Vertical
Group 280 AutoPC Adjsut
0 AutoPCAdjustEnable
1 Frequency Step
2 Frequency Threshold
3 Fine Phase
4 BLKDET
5 PHASEMSK
Group 290 PanelType * Panel Type Check
0 GammaL/R-View
1 GammaL/R-Change
Group 500 Composite (NTSC) Composite / S-Video
0 Total Dots
1 Disp Dots
2 H Back Porch
3 V Back Porch
4 Disp Line
7 Overscan
8 VSBEG
Group 501 Composite (PAL) Composite / S-Video
0 Total Dots
1 Disp Dots
2 H Back Porch
3 V Back Porch
4 Disp Line
Group 502 Composite (SECAM) Composite / S-Video
0 Total Dots
1 Disp Dots
2 H Back Porch
3 V Back Porch
4 Disp Line
Group 510 SCART(480i)
0 Total Dots
1 Disp Dots
2 H Back Porch
Function
YCBCR Level Acquiring Area
YCBCR Level Acquiring Area Height
Torelance of OFFSET Adj.
Torelance of GAIN Adj.
Horizontal Expansion and
contraction rate
vertical Expansion and contraction
rate
Select Individual / synchronizatio
Revise Horizontal Position
Revise Vertical Position
Auto-PC Adj Operation Enable if Un-
supported Signal Input
Frequency Steps of TotalDot
Total Dot Freqency Threshold
Do Phase Adj after Total Dot Adj.
Black Level Detection Area
Phase Detection Filter
Current Setting Check
Setting of Gamma
Read only
Not used
Not used
Read only
Read only
Read only
- 59 -
Initial
Range Note
800
0 - 1000
500
0 - 1000
700
0 - 1000
500
0 - 1000
13
0 - 4095
9
0 - 4095
4
0 - 255
128
0 - 255
128
0 - 255
217
0 - 255
237
0 - 255
237
0 - 255
1
1 - 255
1
1 - 255
100
68 - 132
100
68 - 132
0
0 - 1
0 : Individual 1 : synchronizatio
100
85 - 115
100
85 - 115
0
0 - 1
0: Enable, 1: Disable
1
0 - 3
5
0 - 10
0 [] <--- -----> 10[Not matched]
1
0 - 1
0: Executes Fine Phase, 1: Not Execute
1
0 - 7
0: Effective All Bit,
1: Disable Lower 1 bit
0
0 - 3
2: Disable Lower 2 bit, 3: Disable Lower
3 bit
0: Gamma for L-Turn
0
0-20
20: Gamma for R-Turn * Read only
Sets L-Turn Gamma if the Value is set
to 0.
10
0-20
Sets R-Turn Gamma if the Value is set
to 20.
668
0 ~ 4095
28
0 ~ 4095
18
0 ~ 4095
458
0 ~ 4095
0
0 - 255
2
0 - 15
658
0 ~ 4095
34
0 ~ 4095
22
0 ~ 4095
536
0 ~ 4095
652
0 ~ 4095
28
0 ~ 4095
22
0 ~ 4095
536
0 ~ 4095
662
0 ~ 4095
142
0 ~ 4095
Service Adjustment