Grounding The Device; Connecting To The Device - Siemens RUGGEDCOM RSG2300 Installation Manual

Table of Contents

Advertisement

Chapter 2
Installing Device
Figure 12: Failsafe Alarm Relay Wiring
1. Normally Open
2. Common
Section 2.4

Grounding the Device

The RUGGEDCOM RSG2300 chassis ground terminal uses a #6-32 screw. It is recommended to terminate the
ground connection with a #6 ring lug and torque it to 1.7 N·m (15 lbf·in).
Figure 13: Chassis Ground Connection
1. Stainless Steel Stud
Section 2.5

Connecting to the Device

The following describes the various methods for accessing the ROS console and Web interfaces on the device.
For more detailed instructions, refer to the ROS User Guide for the RUGGEDCOM RSG2300.
16
3. Normally Closed
2. #6-32 Screw
3. #6 Ring Lug
1
3
2
2
3
1
RUGGEDCOM RSG2300
Installation Guide
Grounding the Device