16. Software
16.1
Vehicle database
i
The vehicle database can be updated annually using
a PS2 stick. Further information can be obtained
from customer service.
!
Do not switch off ACS 511 during update process.
!
Follow the additional ACS 511 menu prompting.
1. Call up the start screen.
2. Press <3> and <Flush> simultaneously and release.
 The message
ENTER CODE 0000
2222
and confirm with E .
3. Enter
DATABASE UPDATE
4. Select "
with E .
INSERT THE KEY
5. Remove plastic cover (input PS2 stick) between
menu key and stop key.
6. Insert PS2 stick.
7. Activate or deactivate with o u and confirm with E.
 The update is performed.
"
Data base is updated.
i
Return with <Stop>.
16.2
Data backup
i
This function enables you to save ACS 511 configura-
tion data before a software update. A data backup
avoids the need to recalibrate the ACS 511 after a
software update.
!
Do not turn off the ACS 511 while saving.
!
Follow the additional ACS 511 menu prompting.
1. Call up the start screen.
2. Press <3> and <Flush> simultaneously and release.
 The message
ENTER CODE 0000
5599
and confirm with E .
3. Enter
4. Select "BACKUP" with o u and confirm with E .
INSERT THE KEY
5. Remove plastic cover (input PS2 stick) between
menu key and stop key.
Robert Bosch GmbH
is displayed.
" with o u and confirm
is displayed.
is displayed.
is displayed.
Software | ACS 511 | 37
!
Do not use the PS2 stick with the new software ver-
sion, as the stick is cleared before the data backup.
6. Insert PS2 stick.
7. Confirm that any data on the stick will be deleted.
8. After the backup, remove the stick.
"
The data is saved.
16.3
Software update
i
The software is updated using a PS2 stick. Before
updating, perform a data backup (see section 16.2)
so that the calibration data and settings for the
ACS 511 will not be lost.
1. Turn off the ACS 511.
2. Insert the "System Software" PS2 stick.
3. Press and hold the <MENU> key.
4. Turn on the ACS 511 and release the <MENU> key.
5. The ACS 511 turns itself off after programming.
6. Remove the PS2 stick.
7. Turn on the ACS 511.
16.4
Loading a data backup
i
The calibration data previously saved (section 16.2)
can be reinstalled after the software update.
1. Turn off the ACS 511.
2. Insert the "Data Backup" PS2 stick.
3. Press and hold the <MENU> key.
4. Turn on the ACS 511 and release the <MENU> key.
5. After recovery of the data, remove the PS2 stick and
attach the plastic cover.
6. Check the calibration data.
en
|
1 689 975 252
2019-05-15

Hide quick links: