Bit Mask Options; Sample Load Command; Using Startup.ncf And Autoexec.ncf; Using Scsi Devices - Dell 4100 User Manual

Dell poweredge 4100 servers: user guide
Hide thumbs Also See for 4100:
Table of Contents

Advertisement

Bit Mask Options

Use this example to aid in calculating bit-mask option
hex values. Each SCSI device (ID 0-7 or 0-15 for the
AIC-7880, AIC-7860, and optional AHA-2940W) is
enabled by a 1 in its corresponding bit position. As illus-
trated in Figure 3-1, dev_enable=05 enables driver
registration of the devices at SCSI IDs 0 and 2.
15141312
SCSI ID
0, 2
0 0 0 0
converted
binary-to-hex
= 05h
0

Figure 3-1. Bit Position

Sample load Command

The following command is a sample load command with
no option switches (loaded from drive A):
load a:\scsi\aic7870
Slot values that already have another registered device do
not appear on the screen. Only the slots available for use
by the host adapter appear when this command is entered.
If an error message appears as you attempt to load the
driver, refer to "Troubleshooting for NetWare" found
later in this section.
The following command is a sample command loading
the aic7870.dsk driver with command line options
(loaded from drive A):
load a:\scsi\aic7870 verbose=y slot=22

Using startup.ncf and autoexec.ncf

The startup.ncf and autoexec.ncf files contain a set of
commands that are executed at server bootup. The
startup.ncf file contains commands to load the disk driv-
ers. Once startup.ncf loads disk drivers, control is
passed to the autoexec.ncf file to complete the boot pro-
cess. For additional information on the startup.ncf and
autoexec.ncf files, refer to your NetWare documentation.
3-16
Dell PowerEdge 4100/180 and 4100/200 Systems User's Guide
bit position
111098
7654
3210
0 000
0000
0101
0
0
5
To automatically load the aic7870.dsk at server bootup,
the startup.ncf must contain a load command line that
specifies the location of the driver on the hard-disk drive,
any available options (see "Using the load Command
Line Options" found earlier in this section), and the slot
number (see "Calculating the Slot Number" found earlier
in this section).
NOTE: To load the driver from your hard-disk drive, the
aic7870.dsk driver and aspitran.dsk module must be
copied from your NetWare 3.12 or 4.x driver diskette to a
directory on your hard-disk drive (usually, the server's
start-up directory [for example, c:\nwserver]).
The syntax to load the aic7870.dsk driver is:
load [pathname] aic7870 [options] slot=x
For example, the command line to load the driver from
the c:\nwserver directory, with the verbose
and a slot number of 16 follows:
load c:\nwserver\aic7870 verbose=y slot=16
NOTE: For each Adaptec 78xx host adapter installed, a
separate load command line must be included in the
startup.ncf file. The slot number (slot=) identifies the
specific adapter.
To modify the startup.ncf file, follow these steps:
1.
Type install at the NetWare prompt, and press
<
>.
ENTER
2.
Select the appropriate menu choice that allows
you to edit the startup.ncf file.
3.
Make the necessary changes. When you are fin-
ished, press <
>.
F10

Using SCSI Devices

The following sections provide procedures and tips on
the following topics:
Booting from a SCSI device
Formatting media
Using removable media
Using NetWare-tested and -approved drives
Using the NetWare tape backup utility
Using a CD-ROM drive with NetWare
Optimizing performance
option on,
=

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Poweredge 4100/180Poweredge 4100/200

Table of Contents