Making Selections In The Eisa Configuration Utility; Using Online Instructions; Starting The Eisa Configuration Utility - Dell 4100 User Manual

Dell poweredge 4100 servers: user guide
Hide thumbs Also See for 4100:
Table of Contents

Advertisement

NOTE: If your system detects a card configuration prob-
lem during operation, you receive a warning message
directing you to run the EISA Configuration Utility to
correct the problem.
Making Selections in the EISA Configu-
ration Utility
The EISA Configuration Utility uses menus to guide you
through the configuration process. The menus and their
options are accessed through keyboard commands.
To make a menu selection, use the up- or down-arrow key
to highlight the desired option, and then press <
In the Help menu or Advanced menu, you can also select
an option by pressing the key that corresponds to the
highlighted letter in the selection list.
To scroll up or down a screen, press the <
<
> key, respectively.
PAGE DOWN

Using Online Instructions

The EISA Configuration Utility has online instructions
for each of its procedures. If you need help at any time,
press <
> to see a help screen that offers more details
F1
about the task you are doing.
S
tarting the EISA Configuration
Utility
NOTE: Your system's default hardware configuration
allows updating of the EISA configuration information.
However, if the EISA jumper on the system board is
installed, the EISA configuration information cannot be
updated until the jumper plug is removed.
If you have reason to think the EISA jumper setting has
been changed, have a technician check the jumper before
attempting to make an EISA configuration change. For
information on the EISA jumper location and settings,
see Figure C-1 and Table C-1, respectively, in the Installa-
tion and Troubleshooting Guide.
If you are running the EISA Configuration Utility from
your hard-disk drive, remove any TSR programs from
memory before starting the utility. These programs take
up space in system memory even when they are not run-
ning, thus reducing the amount of memory available to
the EISA Configuration Utility. See the documentation
that accompanied these programs for instructions on
removing them from memory.
If you start the utility and there is not enough memory to
run it, a message is displayed. If you receive such a mes-
sage, run the utility from a diskette.
Follow these steps the first time you use the EISA Con-
figuration Utility. Later, if a card is added, removed, or
repositioned, you must follow the procedure described in
"Step 2: Add or Remove Boards" found later in this
chapter.
1.
>.
ENTER
> or
PAGE UP
To run the program from a diskette, insert into
drive A the EISA Configuration Utility diskette
that you created from the CD. Then either turn
on your computer or reboot it by pressing the
<
><
><
> key combination or the reset
CTRL
ALT
DEL
button.
To run the program from your hard-disk drive, switch
to the c:\eisacfg subdirectory, type
system prompt, and press <
To run the program from the Dell Server Assistant
CD, restart the system from the CD. Select
EISA CONFIGURATION UTILITY
menu.
To access the advanced options (described in
"Advanced Menu" found later in this chapter), press
<
><
> at the Welcome screen.
CTRL
A
You can run the EISA Configuration Utility in mod-
eling mode by typing
prompt and pressing <
ENTER
NOTE: To use modeling mode, you must run the
EISA Configuration Utility from your hard-disk
drive.
Modeling mode lets you set up configuration param-
eters for a system different from the one you are
using and allows you to save a configuration to a
file. Modeling mode is useful if you need to config-
ure many systems identically; instead of using the
EISA Configuration Utility to configure each sys-
tem, you can transfer the configuration file to a
diskette and load it onto each system. See "Modeling
Mode" found later in this chapter for more
information.
Press <
> to return to the Welcome screen.
ESC
Using the EISA Configuration Utility
at the operating
>.
ENTER
RUN
from the CD's main
at the operating system
>.
5-3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Poweredge 4100/180Poweredge 4100/200

Table of Contents