Q U I C K S TA R T G U I D E
Control Panels CP405
Control Panels CP408

Advertisement

loading

Summary of Contents for ABB CP405

  • Page 1 — Q U I C K S TA R T G U I D E Control Panels CP405 Control Panels CP408...
  • Page 2: Table Of Contents

    Content Introduction ....................... 2 Before You Start ......................2 2.1 Hardware Connection ......................2 2.2 Software Installation ......................4 Application Examples - Data Display ..............6 Revision History ...................... 13 Quickstart CP405, CP408...
  • Page 3: Introduction

    Introduction This documentation describes the steps to create a simple CP400PB (Panel Builder 400) project. The description includes hardware, configuration and programming of CP405/CP408 and AC500-eCo in order to communicate with each other. Before You Start 2.1 Hardware Connection Before you start, following equipments should be prepared: 1.
  • Page 4 1. Connect CP405/CP408 (5) with AC500-eCo (3). Pinning of TK407 (8) is shown below. COM1 of AC500-eCo COM1 of CP405/CP408 2. Connect CP405/CP408 (5) with PC (1). 3. Connect AC500-eCo (3) with PC (1) with TK504 (6). 4. Connect 24VDC power supply (2) to CP405/CP408 (5) and AC500-eCo (3).
  • Page 5: Software Installation

    1. Install CP400PB (Panel Builder 400) and CBP (Control Builder Plus) software. For further details, please see AC500-eCo Starter Kits: 2CBA125031M0201 2. After USB programming cable is plugged in PC for the first time, Windows will detect it automatically. Right click ABB CP40x HMI to update the software. Quickstart CP405, CP408...
  • Page 6 3. Browse the driver software. Choose whether Win32bit or Win64bit, depending on your computer system 4. Finish the installation. 5. Check if driver is installed correctly in Device Manager. Quickstart CP405, CP408...
  • Page 7: Application Examples - Data Display

    Application Examples - Data Display Open Panel Builder software to configure the setting on CP400PB. 1. Open CP405/CP408 configuration environment and creat a new project. 2. Input project name and location. Then click Next. 3. Choose corresponding CP405/CP408 type. Then click Next.
  • Page 8 5. Configure the Link parameter of CP405/CP408, which shall be consistent with the used parameter settings in AC500-eCo. Parameter setting for control panel on CP400PB Parameter settings for AC500-eCo on Quickstart CP405, CP408...
  • Page 9 7. Draw a numeric display label to display the data received from AC500-eCo.Choose the data type (Monitored variable type), display type and monitor address. 1. Choose Numeric Display 3. Input Monitor Address 2. Double click the label Quickstart CP405, CP408...
  • Page 10 8. Draw and specify a numeric display label to display the data sent to AC500-eCo. 9. Draw and specify a numeric display label to display the error record (how many times data received from AC500-eCo is not equal to data send to AC500-eCo). Quickstart CP405, CP408...
  • Page 11 10. Double click Screen 1 and check Cycle Macro, the Cycle Macro will be running continuously while the Screen 1 is open. Define the name of Cycle Macro. 11. Write Cycle Macro to perform data exchange operation. 12. Compile the application. Quickstart CP405, CP408...
  • Page 12 13. Click Download icon and select the link before downloading. Step 14 to 17 are the settings on CoDeSys. 14. Program in CoDeSys. Quickstart CP405, CP408...
  • Page 13 15. Set AC500-eCo Communication parameters. 16. Login, download and run the program to AC500-eCo. 17. CP405/CP408 panel display after a few minutes. Quickstart CP405, CP408...
  • Page 14: Revision History

    Revision History Rev. Page (P) Description ind. Chapt. (C) Quickstart CP405, CP408...
  • Page 15 With regard to purchase orders, the agreed particulars shall prevail. ABB AG does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein.