Disposal; Appendix; General Technical Data - Bosch Rexroth WGM Operating Instructions Manual

Oil humidity sensor
Table of Contents

Advertisement

36/46

Disposal

Bosch Rexroth AG, RE 51550-B/09.2019
8 Disposal
Dispose of the parts in such a way that there is no hazard to health or the
environment. When disposing of electronic components and devices, observe the
legal regulations in the country of use.

9 Appendix

9.1 General technical data

Technical data
Operating pressure max.
Medium
Threaded connection
Max. tightening torque
Sensor length from sealing
surface
Max. flow velocity at sensor
Media resistance
50 bar
-20 °C to + 80 °C
G 3/4" pipe thread, Eolastic seal
20 Nm
36 mm
5 m/s
Fluids based on mineral oil
(other fluids on request)