Lubrication; Lubricants; Mounting; Actuator Check - ABB PME120-AI Instructions Manual

Electrical part-turn actuator
Hide thumbs Also See for PME120-AI:
Table of Contents

Advertisement

7. Lubrication

Prior to delivery the actuator is filled with 2.5 l oil in factory.
1)
Fig. 1:
Min. oil quantity;
approx. [l]
Min. oil level [mm]
under inspection
screw
Table 3: The arrow indicates the position of the inspection screw
actuator, replace the highest inspection screw with the separately delivered vent screw.

7.1 Lubricants

Actuator type
PME 120AI
(with integrated electronic unit)
PME 120AN
(for separate electronic unit)
Table 4:

8. Mounting

8.1 Actuator check

- Is the actuator filled with the appropriate oil type?
- Is enough oil in the actuator?
- Did you fasten the separately delivered vent screw in the highest bore (depending on the mounting
orientation)?
- Has the actuator integrated or separate electronic unit?

8.2 Mounting orientation

All mounting orientations seen in Figure 2 are permissible. To facilitate mounting and maintenance,
however, it is recommended to use orientation IMB 3.

8.3 Mounting instructions

- Make sure that the actuator is accessible from all sides to ensure convenient handwheel operation,
electrical connection, and replacement of assemblies.
- Avoid direct exposure to rain, snow and other environmental influences. Select the mounting site
accordingly.
- Exclusively mount the actuator on a rigid, non-vibrating support to avoid relative motion between
the actuator and the valve.
- When mounting the actuator close to heat sources use an insulating layer or shielding.
1)
2)
1)
2)
2)
IMB 3
IMB 6
IMB 7
2.2
2.5
45
2
Ambient temperature
1)
(-25)
- 10°C ... + 55°C
1)
(-25)
- 10°C ... + 65°C
1)
2)
IMB 8
2.2
2.2
42
20
1)
and the vent screw
Oil type
Mobil SHC 629
1)
2)
1)
2)
IMV 5
IMV 6
2.5
2.5
23
17
2)
. After having mounted the
Motorbearing
(grease)
ESSO Beacon 325
5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pme120-an

Table of Contents