Siemens SIMATIC NET RUGGEDCOM RS950G Installation Manual
Siemens SIMATIC NET RUGGEDCOM RS950G Installation Manual

Siemens SIMATIC NET RUGGEDCOM RS950G Installation Manual

Rugged ethernet switches
Hide thumbs Also See for SIMATIC NET RUGGEDCOM RS950G:

Advertisement

Quick Links

Installation Manual
SIMATIC NET
Rugged Ethernet Switches
RUGGEDCOM RS950G
Edition
01/2021
https://www.siemens.com

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC NET RUGGEDCOM RS950G

  • Page 1 Installation Manual SIMATIC NET Rugged Ethernet Switches RUGGEDCOM RS950G Edition 01/2021 https://www.siemens.com...
  • Page 2 Preface Introduction Installing the Device SIMATIC NET Device Management Rugged Ethernet Switches RUGGEDCOM RS950G Communication Ports Technical Specifications Installation Manual Certification 01/2021 C79000-G8976-1037-06...
  • Page 3 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 4: Table Of Contents

    Accessing Documentation ....................... v Registered Trademarks ......................v Warranty ..........................v Training ..........................vi Customer Support ........................vi Contacting Siemens ....................... vii Introduction ........................... 1 Feature Highlights ....................1 Description ......................2 Decommissioning and Disposal ................3 Cabling Recommendations ..................4 High Availability Seamless Ring Operation .............
  • Page 5 Table of Contents Mechanical Specifications ..................22 Dimension Drawings ................... 23 Certification ......................... 25 Approvals ......................25 6.1.1 TÜV SÜD ......................25 6.1.2 European Union (EU) ..................25 6.1.3 FCC ........................26 6.1.4 FDA/CDRH ......................26 6.1.5 ISED ........................26 6.1.6 ISO ........................
  • Page 6: Preface

    Warranty Siemens warrants this product for a period of five (5) years from the date of purchase, conditional upon the return to factory for maintenance during the warranty term. This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void.
  • Page 7: Training

    Siemens Sales representative. Customer Support Customer support is available 24 hours, 7 days a week for all Siemens customers. For technical support or general information, contact Siemens Customer Support through any of the following methods: Online Visit http://www.siemens.com/automation/support-request...
  • Page 8: Contacting Siemens

    Preface Contacting Siemens • Contact a local Siemens representative from Sales, Technical Support, Training, etc. • Ask questions or share knowledge with fellow Siemens customers and the support community Contacting Siemens Address Siemens AG Industry Sector 300 Applewood Crescent Concord, Ontario...
  • Page 9 Preface Contacting Siemens viii RUGGEDCOM RS950G Installation Manual, 01/2021, C79000-G8976-1037-06...
  • Page 10: Introduction

    Introduction The RUGGEDCOM RS950G is an IEC 62439-3 PRP (Parallel Redundancy Protocol) and HSR (High-Availability Seamless Redundancy) redundancy box, or RedBox. The RUGGEDCOM RS950G provides the ultimate in network reliability with Zero-Packet- Loss™ and zero fail-over time from any network fault. IMPORTANT This is a class A product.
  • Page 11: Description

    Introduction 1.2 Description Description The RUGGEDCOM RS950G features various ports, controls and indicator LEDs for connecting, configuring and troubleshooting the device. The final device configuration is determined during the ordering process. The following describes the major options available. POWER LED ALARM LED HSR LED PRP LED Port Status LED...
  • Page 12: Decommissioning And Disposal

    Introduction 1.3 Decommissioning and Disposal ALARM LED Illuminates when an alarm condition exists. HSR LED Illuminates when the device is in HSR Redbox mode. PRP LED Illuminates when the device is in PRP Redbox mode. Port Status LEDs Indicate the status of each port: State Description Solid...
  • Page 13: Cabling Recommendations

    Siemens does not recommend using copper Ethernet ports to interface with devices in the field across distances that could produce high levels of ground potential rise (i.e. greater than 2500 V), during line-to-ground fault conditions.
  • Page 14: 1.5.2 High Availability Seamless Redundancy

    Introduction 1.5.2 High Availability Seamless Redundancy Receiving IED Figure 1.2 PRP Network Design Note PRP expands the Ethernet frame by 6 octets due to RCT (Redundancy Check Trailer). Generation of PRP supervision frames also consumes bandwidth. As a result, the network designer should keep in mind the overhead introduced by the PRP network when calculating the network capacity.
  • Page 15 Introduction 1.5.2 High Availability Seamless Redundancy Note Current HSR implementation limits link utilization to 74% when using multicast traffic. RUGGEDCOM RS950G Installation Manual, 01/2021, C79000-G8976-1037-06...
  • Page 16: Installing The Device

    This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void. Changes or modifications not expressly approved by Siemens AG could invalidate specifications, test results, and agency approvals, and void the user's authority to operate the equipment.
  • Page 17: 2.1.1 Mounting The Device On A Din Rail

    Installing the Device 2.1.1 Mounting the Device on a DIN Rail Note For detailed dimensions of the device with either DIN rail or panel hardware installed, refer to "Dimension Drawings (Page 23)". 2.1.1 Mounting the Device on a DIN Rail For DIN rail installations, the RUGGEDCOM RS950G can be ordered with a DIN rail mounting bracket pre-installed on the rear of the chassis.
  • Page 18: Connecting The Failsafe Alarm Relay

    Installing the Device 2.2 Connecting the Failsafe Alarm Relay Install the mounting brackets to the top and bottom of the chassis using the bracket mounting screws. Make sure the screws are hand-tightened. Place the device against the panel and align the mounting brackets with the mounting holes.
  • Page 19: Connecting Power

    IMPORTANT Siemens requires the use of external surge protection in VDSL applications where the line may be subject to surges greater than that for which the device is rated. Use the following specifications as a guide for VDSL external surge protection: •...
  • Page 20: 2.3.1 Connecting High Ac/Dc Power

    Installing the Device 2.3.1 Connecting High AC/DC Power 2.3.1 Connecting High AC/DC Power NOTICE Electrical hazard – risk of damage to equipment. Do not connect AC power cables to terminals for DC power. Damage to the power supply may occur. NOTICE Electrical hazard –...
  • Page 21: Connecting Low Dc Power

    Installing the Device 2.3.2 Connecting Low DC Power is used as the ground conductor for all surge and transient suppression circuitry internal to the unit. Connect the ground terminal on the power source to the chassis ground terminal on the device. 2.3.2 Connecting Low DC Power The device supports a single low DC power supply with dual power supply inputs.
  • Page 22 Installing the Device 2.3.2 Connecting Low DC Power To connect a low DC power supply to the device, do the following: Connect the positive wire from the power source to the positive terminal on the terminal block. Positive Terminal Negative Terminal Surge Ground Terminal Braided Ground Cable Figure 2.5...
  • Page 23 Installing the Device 2.3.2 Connecting Low DC Power Positive Terminal Negative Terminal Surge Ground Terminal Braided Ground Cable Figure 2.6 Terminal Block Wiring - Dual DC Power Supply Inputs Connect the negative wire from the power source to the negative terminal on the terminal block.
  • Page 24: Device Management

    Device Management This section describes how to connect to and manage the device. Connecting to the Device The following describes the various methods for accessing the RUGGEDCOM RS950G console and Web interfaces on the device. For more detailed instructions, refer to the RUGGEDCOM RS950G User Guide for the RUGGEDCOM RS950G.
  • Page 25 Device Management 3.1 Connecting to the Device the device's IP address. The factory default IP address for the RUGGEDCOM RS950G is https://192.168.0.1. For more information about available ports, refer to "Communication Ports (Page 17)". RUGGEDCOM RS950G Installation Manual, 01/2021, C79000-G8976-1037-06...
  • Page 26: Communication Ports

    Communication Ports The RUGGEDCOM RS950G can be equipped with various types of communication ports to enhance its abilities and performance. To determine which ports are equipped on the device, refer to the factory data file available through RUGGEDCOM RS950G . For more information on how to access the factory data file, refer to the RUGGEDCOM RS950G User Guide for the RUGGEDCOM RS950G.
  • Page 27: Sfp Transceivers

    22)". SFP Transceivers The RUGGEDCOM RS950G features three Small Form-Factor Pluggable (SFP) transceiver sockets, which are compatible with a wide array of SFP transceivers available from Siemens. LEDs Each socket features an LED that indicates its link state. RUGGEDCOM RS950G...
  • Page 28 RUGGEDCOM SFP Transceiver Catalog [https:// support.industry.siemens.com/cs/ca/en/view/109482309]. IMPORTANT Only use SFP transceivers approved by Siemens for RUGGEDCOM products. Siemens accepts no liability as a result of performance issues related in whole or in part to third-party components. RUGGEDCOM RS950G...
  • Page 29 Communication Ports 4.2 SFP Transceivers RUGGEDCOM RS950G Installation Manual, 01/2021, C79000-G8976-1037-06...
  • Page 30: Technical Specifications

    Technical Specifications This chapter provides important technical specifications related to the device. Power Supply Specifications Maximum Power Minimum Maximum Internal Isolation Power Supply Type Input Input Fuse Rating Consumption 24 VDC 10 VDC 36 VDC 3.15 (T) 1.5 kVDC 48 VDC 37 VDC 72 VDC 3.15 (T)
  • Page 31: Copper Ethernet Port Specifications

    Technical Specifications 5.4 Copper Ethernet Port Specifications Standard 10 Mbps 100 Mbps 1000 Mbps Ports Notes Ports Ports IEEE VLAN (Virtual LAN) ü ü ü 802.1Q IEEE 802.1p Priority Levels ü ü ü Copper Ethernet Port Specifications The following details the specifications for copper Ethernet ports that can be ordered with the RUGGEDCOM RS950G.
  • Page 32: Dimension Drawings

    Technical Specifications 5.7 Dimension Drawings Dimension Drawings Note All dimensions are in millimeters, unless otherwise stated. 65.02 116.59 7.87 Figure 5.1 Overall Dimensions RUGGEDCOM RS950G Installation Manual, 01/2021, C79000-G8976-1037-06...
  • Page 33 Technical Specifications 5.7 Dimension Drawings 136.91 116.59 78.74 101.60 11.18 13.72 120.65 Figure 5.2 Panel and Din Rail Mount Dimensions RUGGEDCOM RS950G Installation Manual, 01/2021, C79000-G8976-1037-06...
  • Page 34: Certification

    IEC/UL/CSA 62368-1 Information Technology Equipment – Safety – Part 1: General Requirements 6.1.2 European Union (EU) This device is declared by Siemens AG to comply with essential requirements and other relevant provisions of the following EU directives: • EN 62368-1 Information Technology Equipment –...
  • Page 35: 6.1.3 Fcc

    Certification 6.1.3 FCC The device is marked with a CE marking and can be used throughout the European community. A copy of the CE Declaration of Conformity is available from Siemens AG. For contact information, refer to "Contacting Siemens (Page vii)".
  • Page 36: Iso

    Support at https://support.industry.siemens.com/cs/ww/en/view/89855782. 6.1.8 RoHS This device is declared by Siemens AG to meet the requirements of the following RoHS (Restriction of Hazardous Substances) directives for the restricted use of certain hazardous substances in electrical and electronic equipment: China RoHS 2 •...
  • Page 37: 6.1.9 Other Approvals

    Certification 6.1.9 Other Approvals 6.1.9 Other Approvals This device meets the requirements of the following additional standards: • IEEE 1613 IEEE Standard Environmental and Testing Requirements for Communications Networking Devices in Electric Power Substations • IEC 61850-3 Communication Networks and Systems in Substations – Part 3: General Requirements EMC and Environmental Type Tests The RUGGEDCOM RS950G has passed the following EMC and environmental tests.
  • Page 38 DC Line-to-Line 5 kV   AC Line-to-Line 5 kV   Siemens-specified severity levels IEEE 1613 EMC Immunity Type Tests Note The RUGGEDCOM RS950G meets Class 2 requirements for an all-fiber configuration and Class 1 requirements for copper ports. Description Test Levels Enclosure Contact ±...
  • Page 39 Certification 6.2 EMC and Environmental Type Tests Description Test Levels AC Line-to-Line 5 kV Dielectric Strength Signal Ports 2 kV DC Line-to-Line 1.5 kV AC Line-to-Line 2 kV Environmental Type Tests Test Description Test Levels IEC 60068-2-1 Cold Temperature Test Ad -40 °C (-40 °F), 16 Hours IEC 60068-2-2 Dry Heat...
  • Page 40 Further Information Siemens RUGGEDCOM https://www.siemens.com/ruggedcom Industry Online Support (service and support) https://support.industry.siemens.com Industry Mall https://mall.industry.siemens.com Siemens AG Digital Industry Process Automation Postfach 48 48 90026 NÜRNBERG GERMANY...

Table of Contents