Siemens SIMATIC NET RUGGEDCOM RS920W Equipment Manual
Siemens SIMATIC NET RUGGEDCOM RS920W Equipment Manual

Siemens SIMATIC NET RUGGEDCOM RS920W Equipment Manual

Rugged ethernet switches
Hide thumbs Also See for SIMATIC NET RUGGEDCOM RS920W:

Advertisement

Quick Links

Edition
11/2023
Equipment Manual
SIMATIC NET
Rugged Ethernet switches
RUGGEDCOM RS920W
https://www.siemens.com/ruggedcom

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC NET RUGGEDCOM RS920W

  • Page 1 Edition 11/2023 Equipment Manual SIMATIC NET Rugged Ethernet switches RUGGEDCOM RS920W https://www.siemens.com/ruggedcom...
  • Page 2 Preface Introduction Installing the Device SIMATIC NET Device Management Rugged Ethernet switches RUGGEDCOM RS920W Communication Ports Technical Specifications Equipment Manual Certification 11/2023 C79000-G8976-1033-12...
  • Page 3 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 4: Table Of Contents

    SIMATIC NET glossary ......................vi Registered trademarks ......................vi Warranty ..........................vii Training ..........................vii Customer support ......................... viii Contacting Siemens ......................viii Introduction ........................... 1 Feature Highlights ....................2 Description ......................2 Required Tools and Materials ................. 4 Decommissioning and disposal ................4 Cabling Recommendations ..................
  • Page 5 Table of contents Technical Specifications ...................... 27 General specifications ..................27 Power Supply Specifications ................27 Failsafe Alarm Relay Specifications ..............27 Supported Networking Standards ................ 28 Serial Port Specifications ..................28 Operating Environment ..................28 Mechanical Specifications ..................29 Dimension Drawings ...................
  • Page 6: Preface

    Siemens' products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customer's exposure to cyber threats.
  • Page 7: Supplementary Documentation

    SIMATIC NET glossary The SIMATIC NET glossary describes special terms that may be used in this document. The glossary is available online via Siemens Industry Online Support (SIOS) at: https://support.industry.siemens.com/cs/ww/en/view/50305045 Registered trademarks The following and possibly other names not identified by the registered trademark sign ®...
  • Page 8: Warranty

    Warranty Siemens warrants this product for a period of five (5) years from the date of purchase, conditional upon the return to factory for maintenance during the warranty term. This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void.
  • Page 9: Customer Support

    Call a local hotline center to submit a Support Request (SR). To locate a local hotline center, visit https://w3.siemens.com/aspa_app/?lang=en. Mobile app Install the Industry Online Support app by Siemens AG on any Android, Apple iOS or Windows mobile device and be able to: •...
  • Page 10: Introduction

    Introduction The RUGGEDCOM RS920W is a utility-grade serial device server that combines an IEEE 802.11b/g Local Area Network (LAN) with wired serial ports. It allows network designers to connect any RS232/422/485 serial device at up to 230 kbps for wireless access and control via an IEEE 802.11i WLAN.
  • Page 11: Feature Highlights

    Introduction 1.1 Feature Highlights Feature Highlights Serial Interface • 2 x RS485/RS422/RS232 Serial Ports (DB9 or RJ45) • [Optional] Serial Fiber Interface (ST) Ethernet Over VDSL (EoVDSL) • 1 x Ethernet over VDSL (EoVDSL) ports • Symmetric data rates up to 35 Mbps •...
  • Page 12 Introduction 1.2 Description POWER LED ALARM LED EoVDSL Port Wireless Ethernet Ports Serial Ports RS232 Console Port (Serial) Failsafe Alarm Relay Chassis Ground Connection Power Supply Terminal Block Figure 1.1 RUGGEDCOM RS920W POWER LED Illuminates green during boot up and when power is supplied to the device.
  • Page 13: Required Tools And Materials

    WEEE directive 2012/19/EU for the disposal of electrical and electronic equipment. Do not dispose of devices at public disposal sites. For environmentally friendly recycling and the disposal of devices, contact a certified disposal company for electronic scrap or your Siemens contact. For more information, refer to https://support.industry.siemens.com/cs/ww/en/ view/109479891.
  • Page 14: Cabling Recommendations

    Siemens also does not recommend using copper Ethernet ports to interface with devices in the field across distances that could produce high levels of ground potential rise (i.e. greater than 2500 V), during line-to-ground fault conditions.
  • Page 15 Introduction 1.5 Cabling Recommendations RUGGEDCOM RS920W Equipment Manual, 11/2023, C79000-G8976-1033-12...
  • Page 16: Installing The Device

    Installing the Device This chapter describes how to install the device, including mounting the device, connecting power, and connecting the device to the network. DANGER Electrocution hazard – risk of serious personal injury and/or damage to equipment Before performing any maintenance tasks, make sure all power to the device has been disconnected and wait approximately two minutes for any remaining energy to dissipate.
  • Page 17: General Procedure

    This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void. Changes or modifications not expressly approved by Siemens Canada Ltd. could invalidate specifications, test results, and agency approvals, and void the user's authority to operate the equipment.
  • Page 18: Mounting The Device

    Installing the Device 2.3 Mounting the Device Note If any item is missing or damaged, contact Siemens for assistance. Mounting the Device The RUGGEDCOM RS920W is designed for maximum mounting and display flexibility. It can be equipped with adapters that allow it to be attached to a DIN rail or panel.
  • Page 19 Installing the Device 2.3.1 Mounting the Device on a DIN Rail DIN Rail DIN Rail Adapter Figure 2.1 Mounting the Device to a DIN Rail Insert a flathead screwdriver into the slot of the sliding release and move it down. Push the device against the bottom of the DIN rail, then let go of the sliding release to latch the device.
  • Page 20: 2.3.2 Mounting The Device To A Panel

    Installing the Device 2.3.2 Mounting the Device to a Panel DIN Rail DIN Rail Adapter Figure 2.2 Removing the Device from a DIN Rail Swing the bottom of the device away from the DIN rail. Lift the device off the DIN rail. 2.3.2 Mounting the Device to a Panel For panel installations, the RUGGEDCOM RS920W can be equipped with panel...
  • Page 21: Connecting The Failsafe Alarm Relay

    Installing the Device 2.4 Connecting the Failsafe Alarm Relay Screw (M3.5 or #6-32) Panel Mount Adapter Figure 2.3 Panel Mounting Secure the adapters to the panel with M3.5 or #6-32 screws. Connecting the Failsafe Alarm Relay The failsafe relay can be configured to latch based on alarm conditions. The NO (Normally Open) contact is closed when the unit is powered and there are no active alarms.
  • Page 22: Connecting Power

    Installing the Device 2.5 Connecting Power Normally Closed Common Normally Open Figure 2.4 Failsafe Alarm Relay Wiring Connecting Power The RUGGEDCOM RS920W supports power input from a single high AC/DC or low DC power supply. Note • For 110/230 VAC rated equipment, an appropriately rated AC circuit breaker must be installed.
  • Page 23: 2.5.1 Connecting High Ac/Dc Power

    Installing the Device 2.5.1 Connecting High AC/DC Power 2.5.1 Connecting High AC/DC Power To connect a high AC/DC power supply to the device, do the following: NOTICE Electrical hazard – risk of damage to equipment Do not connect AC power cables to terminals for DC power. Damage to the power supply may occur.
  • Page 24: 2.5.2 Connecting Low Dc Power

    Installing the Device 2.5.2 Connecting Low DC Power Braided Ground Cable Figure 2.5 Terminal Block Wiring ± ± ± ± Positive Terminal Negative Terminal Surge Ground Terminal Braided Ground Cable Figure 2.6 Terminal Block Wiring – Dual DC Power Supply Inputs Connect the negative wire from the power source to the negative/neutral (-/N) terminal on the terminal block.
  • Page 25 Installing the Device 2.5.2 Connecting Low DC Power Connect the positive wire from the power source to the positive terminal on the terminal block. ± ± Positive Terminal Negative Terminal Surge Ground Terminal Braided Ground Cable Figure 2.7 Terminal Block Wiring – Single DC Power Supply Inputs Connect the negative wire from the power source to the negative terminal on the terminal block.
  • Page 26 Installing the Device 2.5.2 Connecting Low DC Power ± ± ± ± Positive Terminal Negative Terminal Surge Ground Terminal Braided Ground Cable Figure 2.8 Terminal Block Wiring – Dual DC Power Supply Inputs Using a braided wire or other appropriate grounding wire, connect the surge ground terminal to the chassis ground connection.
  • Page 27 Installing the Device 2.5.2 Connecting Low DC Power RUGGEDCOM RS920W Equipment Manual, 11/2023, C79000-G8976-1033-12...
  • Page 28: Device Management

    Device Management This section describes how to connect to and manage the device. Connecting to the Device The following describes the various methods for accessing the RUGGEDCOM RS920W console and Web interfaces on the device. For more detailed instructions, refer to the "RUGGEDCOM ROS Configuration Manual"...
  • Page 29: Configuring The Device

    Device Management 3.2 Configuring the Device The serial console port implements RS232 DCE (Data Communication Equipment) on a DB9 connector. The following is the pin-out for the port:   Name Description Reserved (Do Not Connect) Transmit Data Receive Data Reserved (Do Not Connect) Signal Ground Reserved (Do Not Connect) Reserved (Do Not Connect)
  • Page 30: Communication Ports

    Communication Ports The RUGGEDCOM RS920W can be equipped with various types of communication ports to enhance its abilities and performance. Ports 1 and 2 Port 3 Port 9 Figure 4.1 Port Assignment Port Type 1 and 2 Serial Ports (DB9, RJ45, or ST) EoVDSL Port Wireless Antennas Wireless Ethernet Ports...
  • Page 31: 4.1.1 Supported Wireless Standards

    Communication Ports 4.1.1 Supported Wireless Standards 4.1.1 Supported Wireless Standards Standard Parameter Mode Notes IEEE 802.11g 54 Mbps (WLAN) Full Access Point 2.4 GHz ISM IEEE 802.11b 11 Mbps (WLAN) Client support Backwards compatibility Robust Secure Strong Encryption WPA2-AES (CCMP) Network (RSN) IEEE 802.11i Enhanced Encryption WPA-TKIP (RC4)
  • Page 32: Eovdsl Ports

    EoVDSL line configuration settings are modified on the Master and pushed to the Slave. Data flowing from the Master to the Slave is designated downstream, while data flowing from the Slave to the Master is designated upstream. Siemens supports two types of EoVDSL: • Universal EoVDSL Universal EoVDSL ports are Master/Slave selectable and offer symmetric data rates (upstream and downstream) up to 35 Mbps.
  • Page 33 Communication Ports 4.2 EoVDSL Ports NOTICE Universal and Long-Reach EoVDSL ports (master or slave) must be connected to EoVDSL ports (slave or master) of the same type. Connection between Universal EoVDSL ports and Long-Reach EoVDSL ports is not supported. While master/slave mode can be modified on Universal EoVDSL ports, the operating mode of all Long- Reach EoVDSL ports is predetermined by hardware.
  • Page 34: Serial Ports

    Communication Ports 4.3 Serial Ports Serial Ports The RUGGEDCOM RS920W supports DB9, RJ45 and ST (Straight Tip) fiber serial ports, all of which can be run in RS232, RS485 or RS422 mode. Note On power-up, all serial ports default to RS485 mode. Each port can be individually set to RS232, RS485 or RS422 mode through RUGGEDCOM RS920W.
  • Page 35 Communication Ports 4.3 Serial Ports RUGGEDCOM RS920W Equipment Manual, 11/2023, C79000-G8976-1033-12...
  • Page 36: Technical Specifications

    Technical Specifications This section provides important technical specifications related to the device. General specifications Insulation Class I Overvoltage category OVC II Power Supply Specifications Note When determining cable lengths, make sure the nominal input voltage for the power supply is provided at the power source. Power Input Voltage Internal...
  • Page 37: Supported Networking Standards

    Technical Specifications 5.4 Supported Networking Standards Supported Networking Standards The following networking standards are supported by RUGGEDCOM RS920W: Standard 10 Mbps 100 Mbps 1000 Mbps Ports Notes Ports Ports IEEE 802.3x • • • Full Duplex Operation IEEE 802.3z     •...
  • Page 38: Mechanical Specifications

    Technical Specifications 5.7 Mechanical Specifications Non-condensing. Mechanical Specifications Weight 1.2 kg (2.7 lbs) Enclosure 20 AWG Galvanized Steel Dimension Drawings Note All dimensions are in millimeters, unless otherwise stated. 65.3 116.59 7.87 Figure 5.1 Overall Dimensions RUGGEDCOM RS920W Equipment Manual, 11/2023, C79000-G8976-1033-12...
  • Page 39 Technical Specifications 5.8 Dimension Drawings 132.9 13.64 101.6 11.2 78.74 120.65 Figure 5.2 Panel and DIN Rail Mount Dimensions RUGGEDCOM RS920W Equipment Manual, 11/2023, C79000-G8976-1033-12...
  • Page 40: Certification

    Approvals This section details the standards to which the RUGGEDCOM RS920W complies. Note All relevant certificates and test reports are available on Siemens Industry Online Support [https://support.industry.siemens.com/cs/ww/en/ps/16008/cert]. 6.1.1 This device meets the requirements of the following Canadian and U.S. standards under certificate 1550963: •...
  • Page 41: European Union (Eu)

    Certification 6.1.2 European Union (EU) 6.1.2 European Union (EU) This device is declared by Siemens Canada Ltd. to comply with essential requirements and other relevant provisions of the following EU directives: • EN 62368-1 Information Technology Equipment – Safety – Part 1: General Requirements •...
  • Page 42: Ised

    Title 21 Code of Federal Regulations (CFR) – Chapter I – Sub-chapter J – Radiological Health 6.1.5 ISED This device is declared by Siemens Canada Ltd. to meet the requirements of the following ISED (Innovation Science and Economic Development Canada) standard: • CAN ICES-3 (A)/NMB-3 (A) 6.1.6...
  • Page 43: 6.1.9 Other Approvals

    Certification 6.1.9 Other Approvals 6.1.9 Other Approvals This device meets the requirements of the following additional standards: • IEC 61000-6-2 Electromagnetic Compatibility (EMC) – Part 6-2: Generic Standards – Immunity for Industrial Environments EMC and Environmental Type Tests The RUGGEDCOM RS920W has passed the following Electromagnetic Compatibility (EMC) and environmental tests.
  • Page 44 Certification 6.2 EMC and Environmental Type Tests Test Description Test Levels Severity Levels Damped Oscillatory Signal Ports 2.5 kV Common 61000-4-12 Mode @ 1 MHz 1 kV Differential Mode @ 1 MHz DC Power 2.5 kV Common Ports Mode @ 1 MHz 1 kV Differential Mode @ 1 MHz AC Power...
  • Page 45 Certification 6.2 EMC and Environmental Type Tests Description Test Levels Fast Transient Signal Ports ± 4 kV @ 2.5 kHz DC Power Ports ± 4 kV AC Power Ports ± 4 kV Earth Ground Ports ± 4 kV Oscillatory Signal Ports 2.5 kV Common Mode @ 1 MHz DC Power Ports 2.5 kV Common and...
  • Page 46 For more information Siemens RUGGEDCOM https://www.siemens.com/ruggedcom Industry Online Support (service and support) https://support.industry.siemens.com Industry Mall https://mall.industry.siemens.com Siemens Canada Ltd. Digital Industries Process Automation 300 Applewood Crescent Concord, Ontario, L4K 4E5 Canada © 2023 Siemens Canada Ltd. Subject to change...

Table of Contents