Siemens SIMATIC NET RUGGEDCOM M969 Equipment Manual
Siemens SIMATIC NET RUGGEDCOM M969 Equipment Manual

Siemens SIMATIC NET RUGGEDCOM M969 Equipment Manual

Rugged ethernet switches
Hide thumbs Also See for SIMATIC NET RUGGEDCOM M969:

Advertisement

Quick Links

Edition
10/2023
Equipment Manual
SIMATIC NET
Rugged Ethernet switches
RUGGEDCOM M969
https://www.siemens.com/ruggedcom

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC NET RUGGEDCOM M969

  • Page 1 Edition 10/2023 Equipment Manual SIMATIC NET Rugged Ethernet switches RUGGEDCOM M969 https://www.siemens.com/ruggedcom...
  • Page 2 Preface Introduction Installing the Device SIMATIC NET Device Management Rugged Ethernet switches RUGGEDCOM M969 Communication Ports Technical Specifications Equipment Manual Accessories Certification 10/2023 C79000-G8976-1039-05...
  • Page 3 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 4: Table Of Contents

    SIMATIC NET glossary ......................vi Registered trademarks ......................vi Warranty ..........................vii Training ..........................vii Customer support ......................... viii Contacting Siemens ......................viii Introduction ........................... 1 Feature Highlights ....................1 Description ......................2 Required Tools and Materials ................. 5 Decommissioning and disposal ................6 Cabling Recommendations ..................
  • Page 5 Table of contents Failsafe Alarm Relay Specifications ..............25 Copper Ethernet Port Specifications ..............25 Fiber Optic Ethernet Port Specifications ............... 26 Operating Environment ..................27 Mechanical Specifications ..................27 Dimension Drawings ................... 27 Accessories .......................... 31 Power (1/unit) ..................... 31 Console (1/unit) ....................
  • Page 6: Preface

    Siemens' products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customer's exposure to cyber threats.
  • Page 7: Supplementary Documentation

    SIMATIC NET glossary The SIMATIC NET glossary describes special terms that may be used in this document. The glossary is available online via Siemens Industry Online Support (SIOS) at: https://support.industry.siemens.com/cs/ww/en/view/50305045 Registered trademarks The following and possibly other names not identified by the registered trademark sign ®...
  • Page 8: Warranty

    Warranty Siemens warrants this product for a period of five (5) years from the date of purchase, conditional upon the return to factory for maintenance during the warranty term. This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void.
  • Page 9: Customer Support

    Call a local hotline center to submit a Support Request (SR). To locate a local hotline center, visit https://w3.siemens.com/aspa_app/?lang=en. Mobile app Install the Industry Online Support app by Siemens AG on any Android, Apple iOS or Windows mobile device and be able to: •...
  • Page 10: Introduction

    Introduction The RUGGEDCOM M969 is a MIL-STD hardened, fully managed Ethernet switch providing dual fiber optical Fast Ethernet or Gigabit Ethernet ports and eight Fast Ethernet copper ports in a MIL-STD 901D rated package (for protection against vibration and shock impacts). Designed to operate reliably in harsh environments, the RUGGEDCOM M969 provides: •...
  • Page 11: Description

    Introduction 1.2 Description Universal Power Supply Options • Fully integrated power supply • Universal high-voltage range: 88-300 VDC or 85-264 VAC. • Popular low-voltage DC ranges: 12, 24, 48 VDC • Dual redundant, parallel load-sharing power supplies (option) • Can be powered from different sources for ultimate redundancy •...
  • Page 12 Introduction 1.2 Description Copper Ethernet Ports Port Status LED POWER 1 LED POWER 2 LED ALARM LED RS-232 Console Port Failsafe Output Relay M12 Power Supply Port Fiber Optic Ethernet Ports RUGGEDCOM M969 Equipment Manual, 10/2023, C79000-G8976-1039-05...
  • Page 13 Introduction 1.2 Description Surge Ground Connection Chassis Ground Connection Figure 1.1 RUGGEDCOM M969 (M12 Connectors Shown) Copper Ethernet Ports Port Status LED POWER 1 LED RUGGEDCOM M969 Equipment Manual, 10/2023, C79000-G8976-1039-05...
  • Page 14: Required Tools And Materials

    Introduction 1.3 Required Tools and Materials POWER 2 LED ALARM LED RS-232 Console Port Failsafe Output Relay M23 Power Supply Port Fiber Optic Ethernet Ports Surge Ground Connection Chassis Ground Connection Figure 1.2 RUGGEDCOM M969 (RJ45 Connectors Shown) Port Status LED Indicate the status of each port. State Description Yellow (Solid)
  • Page 15: Decommissioning And Disposal

    Siemens recommends using RUGGEDCOM industrial Ethernet shielded cables for all Ethernet ports. Siemens does not recommend the use of copper cabling of any length for critical, real-time substation automation applications. All copper Ethernet ports on RUGGEDCOM products include transient suppression circuitry to protect against damage from electrical transients and conform with IEC 61850-3 and IEEE 1613 Class 1 standards.
  • Page 16: 1.5.1 Supported Fiber Optic Cables

    Introduction 1.5.1 Supported fiber optic cables Siemens also does not recommend using copper Ethernet ports to interface with devices in the field across distances that could produce high levels of ground potential rise (i.e. greater than 2500 V), during line-to-ground fault conditions.
  • Page 17 Introduction 1.5.1 Supported fiber optic cables RUGGEDCOM M969 Equipment Manual, 10/2023, C79000-G8976-1039-05...
  • Page 18: Installing The Device

    Installing the Device This chapter describes how to install the device, including mounting the device, connecting power, and connecting the device to the network. DANGER Electrocution hazard – risk of serious personal injury and/or damage to equipment Before performing any maintenance tasks, make sure all power to the device has been disconnected and wait approximately two minutes for any remaining energy to dissipate.
  • Page 19: General Procedure

    This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void. Changes or modifications not expressly approved by Siemens Canada Ltd. could invalidate specifications, test results, and agency approvals, and void the user's authority to operate the equipment.
  • Page 20: Mounting The Device

    Installing the Device 2.3 Mounting the Device Note If any item is missing or damaged, contact Siemens for assistance. Mounting the Device The RUGGEDCOM M969 is designed to be mounted on a panel by affixing the top and bottom flanges of the device to a panel using screws.
  • Page 21: Connecting The Failsafe Alarm Relay

    Installing the Device 2.4 Connecting the Failsafe Alarm Relay Flange Figure 2.1 Panel Mounting (Typical) Install the supplied screws to secure the flanges to the panel. Connecting the Failsafe Alarm Relay The Failsafe output relay is provided to signal critical error conditions that may occur on the RUGGEDCOM M969 series switches.
  • Page 22: Connecting Power

    Installing the Device 2.5 Connecting Power The proper relay connections are as follows:   Description Normally Closed Common Normally Open Figure 2.2 Failsafe Alarm Relay Wiring Connecting Power The M23 power connector has five terminal pins, which means two power supply sources are allowed to power the RUGGEDCOM M969 with the M23 power connector.
  • Page 23: 2.5.2 Power Supply Wiring

    Installing the Device 2.5.2 Power Supply Wiring Terminal # Description Usage bus for DC inputs. This terminal is connected to chassis ground internally. An additional chassis ground screw is also present that connects chassis ground to both power supply surge grounds via a removable jumper.
  • Page 24 Installing the Device 2.5.2 Power Supply Wiring Neutral Safety Line 250 VAC Breaker 110/230 VAC Power Source Safety Earth Figure 2.4 AC Power Supply Wiring Example (M23 Power Connector) Single Low DC Power Supply Wiring M23 Power Connector Ground Bus 300 VDC Breaker DC Power Source Figure 2.5 DC Power Supply Wiring Example (M23 Connector)
  • Page 25 Installing the Device 2.5.2 Power Supply Wiring 250 VAC Breaker Neutral 110/230 VAC Power Source (PS2) 110/230 VAC Power Source (PS1) Safety Figure 2.6 AC and AC Power Supply Wiring Example M23 Power Connector Ground Bus Line 250 VAC Breaker 110/230 VAC Power Source (PS2) Neutral Safety 300 VDC Breaker...
  • Page 26: 2.5.3 Disabling Line-To-Ground Transient Protection

    Installing the Device 2.5.3 Disabling Line-to-Ground Transient Protection Ground Bus 300 VDC Breaker DC Power Source (PS2) DC Power Source (PS1) Figure 2.8 DC and DC Power Supply Wiring Example 2.5.3 Disabling Line-to-Ground Transient Protection All line-to-ground transient energy is shunted to the Surge Ground terminal. In cases where users require the inputs to be isolated from ground, remove the ground braid between Surge and Chassis Ground.
  • Page 27 Installing the Device 2.5.3 Disabling Line-to-Ground Transient Protection RUGGEDCOM M969 Equipment Manual, 10/2023, C79000-G8976-1039-05...
  • Page 28: Device Management

    Device Management This section describes how to connect to and manage the device. Connecting to the Device The following describes the various methods for accessing the RUGGEDCOM M969 console and Web interfaces on the device. For more detailed instructions, refer to the "RUGGEDCOM M969 Configuration Manual"...
  • Page 29: Configuring The Device

    Device Management 3.2 Configuring the Device device's IP address. The factory default IP address for the RUGGEDCOM M969 is https://192.168.0.1. For more information about available ports, refer to "Communication Ports" (Page 21). Configuring the Device Once the device is installed and connected to the network, it must be configured. All configuration management is done via the RUGGEDCOM M969 interface.
  • Page 30: Communication Ports

    Communication Ports The RUGGEDCOM M969 can be equipped with various types of communication ports to enhance its abilities and performance. To determine which ports are equipped on the device, refer to the factory data file available through RUGGEDCOM M969. For more information on how to access the factory data file, refer to the "RUGGEDCOM M969 User Guide"...
  • Page 31: Copper Ethernet Ports

    Communication Ports 4.1 Copper Ethernet Ports RJ45 Copper Ethernet Ports Fiber Optic Ethernet Ports Figure 4.2 Port Assignment (RJ45 Connectors Shown) Copper Ethernet Ports The RUGGEDCOM M969 supports eight 10/100Base-TX Ethernet ports that allow connection to standard Category 5 (CAT-5) unshielded twisted-pair (UTP) cables with RJ45 male connectors or M12 male connectors.
  • Page 32: Fiber Optic Ethernet Ports

    Communication Ports 4.2 Fiber Optic Ethernet Ports cause excessive noise and interference, but more importantly, create a potential shock hazard that can result in serious injury. Pin-Out (RJ45) The following is the pin-out description for the RJ45 connectors:   10/100Base- Description TX Signal Receive Data+ Receive Data-...
  • Page 33 Communication Ports 4.2 Fiber Optic Ethernet Ports Tx Connector Rx Connector Figure 4.5 LC Port For specifications on the available fiber optic Ethernet ports, refer to "Fiber Optic Ethernet Port Specifications" (Page 26). RUGGEDCOM M969 Equipment Manual, 10/2023, C79000-G8976-1039-05...
  • Page 34: Technical Specifications

    Technical Specifications This section details the specifications and operating conditions of the device. General specifications Insulation Class I Overvoltage category OVC II Power Supply Specifications Power Minimum Maximum Internal Isolation Maximum Supply Type Input Input Fuse Rating Power Consumption 12–24 VDC 10 VDC 36 VDC 3.15A (T)
  • Page 35: Fiber Optic Ethernet Port Specifications

    All cabling is duplex type unless otherwise specified. • Maximum segment length is greatly dependent on factors such as fiber quality, and the number of patches and splices. Consult a Siemens sales associate when determining maximum segment distances. • All optical power numbers are listed as dBm averages. To convert from average to peak, add 3 dBm.
  • Page 36: Operating Environment

    Technical Specifications 5.6 Operating Environment Operating Environment The RUGGEDCOM M969 is rated to operate under the following environmental conditions. Ambient Operating -40 to 85° C (-40 to 185° F) Temperature Ambient Storage -40 to 85° C (-40 to 185° F) Temperature Ambient Relative 5% to 95% Humidity...
  • Page 37 Technical Specifications 5.8 Dimension Drawings Figure 5.1 8 RJ45 IP67 Ethernet Ports and M23 Power RUGGEDCOM M969 Equipment Manual, 10/2023, C79000-G8976-1039-05...
  • Page 38 Technical Specifications 5.8 Dimension Drawings Figure 5.2 8 M12 D-Code Ethernet Ports and M23 Power RUGGEDCOM M969 Equipment Manual, 10/2023, C79000-G8976-1039-05...
  • Page 39 Technical Specifications 5.8 Dimension Drawings RUGGEDCOM M969 Equipment Manual, 10/2023, C79000-G8976-1039-05...
  • Page 40: Accessories

    Accessories This chapter details the various accessories available for the RUGGEDCOM M969. Power (1/unit) M23 Power Mating Connector  • Description M23 5pin female connector, 600V, IP68 rated • Order Code 99-60-0007 Cable Specifications • 3/18 AWG, jacket OD range 0.20" - 0.48"...
  • Page 41: Console (1/Unit)

    Accessories 6.2 Console (1/unit) Figure 6.2 M23 Power Cable Console (1/unit) M12 Console Port Mating Cable  • Description M12 8pin A-code male to DB9 female; unshielded, PUR jacket cable, 30V/4A, 3m • Order Code 99-43-0023-001 Cable Specifications • M12 8pin A-code male to free end, Figure 6.3 M12 Console Port Mating Cable...
  • Page 42: Failsafe (1/Unit)

    Accessories 6.3 Failsafe (1/unit) Figure 6.4 M12 Console Port Mating Connector Failsafe (1/unit) M12 FailSafe Port Mating Cable Description  • M12 4pole A-coded; unshielded, PUR Jacket cable, 3m • Order Code 99-43-0024-001 Figure 6.5 M12 FailSafe Port Mating Cable M12 FailSafe Port Mating Connector  •...
  • Page 43: Ethernet (8/Unit)

    Accessories 6.4 Ethernet (8/unit) Figure 6.6 M12 FailSafe Port Mating Connector Ethernet (8/unit) M12 D-code Ethernet Port Mating Cable  • Description M12 D-code to RJ45; patch cable, 3meters • Order Code 99-43-0040-001 • Cable Specifications M12 D-code male 4 pin, CAT5e, 3m Figure 6.7 M12 D-code Ethernet Port Mating Cable...
  • Page 44 Accessories 6.4 Ethernet (8/unit) Figure 6.8 M12 D-code Ethernet Port Mating Connector M12 D-Code Ethernet Port Mating Cable  • Description M12 male D-code to male D-code; shielded PUR jacket patch cable, 5 meters • Order Code 99-43-0041-001 Cable Specifications • M12 male 4 pin, CAT 5e, 5m Figure 6.9 M12 D-Code Ethernet Port Mating Cable...
  • Page 45 Accessories 6.4 Ethernet (8/unit)  • Description IP67 Metal RJ45 plug on both ends; Category 5e shielded patch cable, • Order Code 99-43-0039-001 Figure 6.11 IP67 Metal RJ45 Ethernet Port Mating Cable IP67 Metal RJ45 Ethernet Port Mating Connector Description  • IP67 Metal RJ45 plug, field attachable Order Code •...
  • Page 46: Lc Fiber Optic (2/Unit)

    Accessories 6.5 LC Fiber Optic (2/unit) LC Fiber Optic (2/unit) LC Port Mating Connector Description  • Cable Multimode Metal IP67LC to LC, Multimode fiber cable 3meters, IP67 rated • Order Code 99-43-0057-001 Figure 6.14 LC Port Mating Connector  • Description Cable Singlemode Metal IP67 LC to LC, Singlemode fiber cable 3 meters, IP67 rated •...
  • Page 47 Accessories 6.5 LC Fiber Optic (2/unit) Figure 6.16 LC Port Mating Connector  • Description Cable Singlemode Metal IP67 LC to Metal IP67 LC, Singlemode fiber cable 3 meters, IP67 rated Order Code • 99-43-0053-001 Figure 6.17 LC Port Mating Connector LC Port Mating Connector  •...
  • Page 48 Accessories 6.5 LC Fiber Optic (2/unit) LC, RJ45 Port Cap  • Description RJ45 outlet cap IP67, Metal • Order Code 99-60-0011 Figure 6.20 LC, RJ45 Port Cap RUGGEDCOM M969 Equipment Manual, 10/2023, C79000-G8976-1039-05...
  • Page 49 Accessories 6.5 LC Fiber Optic (2/unit) RUGGEDCOM M969 Equipment Manual, 10/2023, C79000-G8976-1039-05...
  • Page 50: Certification

    Approvals This section details the standards to which the RUGGEDCOM M969 complies. Note All relevant certificates and test reports are available on Siemens Industry Online Support [https://support.industry.siemens.com/cs/ww/en/ps/16008/cert]. 7.1.1 UKCA This device is certified for use in Great Britain and bears the United Kingdom Certified Assessed (UKCA) marking.
  • Page 51: European Union (Eu)

    Certification 7.1.3 European Union (EU) 7.1.3 European Union (EU) This device is declared by Siemens Canada Ltd. to comply with essential requirements and other relevant provisions of the following EU directives: • EN 62368-1 Information Technology Equipment – Safety – Part 1: General Requirements •...
  • Page 52: Fda/Cdrh

    Title 21 Code of Federal Regulations (CFR) – Chapter I – Sub-chapter J – Radiological Health 7.1.6 ISED This device is declared by Siemens Canada Ltd. to meet the requirements of the following ISED (Innovation Science and Economic Development Canada) standard: • CAN ICES-3 (A)/NMB-3 (A) This device further complies with IC RSS-210 and is approved under the ID 4997A- VG5RW80G.
  • Page 53: 7.1.9 Rohs

    Support at https://support.industry.siemens.com/cs/ww/en/view/89855782. 7.1.9 RoHS This device is declared by Siemens Canada Ltd. to meet the requirements of the following RoHS (Restriction of Hazardous Substances) directives for the restricted use of certain hazardous substances in electrical and electronic equipment: EU RoHS Directives (EU) 2011/65 and (EU) 2015/863 •...
  • Page 54: Mil-Std Test Specifications

    Certification 7.2 MIL-STD Test Specifications MIL-STD Test Specifications Test Description MIL-STD-167 Vibration Navy MIL-STD –167-1 Type I MIL-STD-461E CE101 CE102 DC 28V AC 115V RE101 RE102 RE102-1, Surface Ship Applications RE102-2, Submarine Applications, Internal RE102-3, AirCraft and Space Applications RE102-4, Ground Applications CS101 CS114 CS115...
  • Page 55 Certification 7.3 EMC and Environmental Type Tests IEC 61850-3 Type Tests Test Description Test Levels Severity Levels IEC 61000-4-2 Enclosure ± 8 kV Contact Enclosure Air ± 15 kV IEC 61000-4-3 Radiated RFI Enclosure ports 20 V/m IEC 61000-4-4 Burst (Fast Signal ports ±...
  • Page 56 Certification 7.3 EMC and Environmental Type Tests Test Description Test Levels Severity Levels AC Power ports 5 kV — IEEE 1613 Type Tests Note • If the unit contains copper ports, the IEEE 1613 conformance is Class 1 (during disturbance, errors may occur but recovery is automatic). •...
  • Page 57 Certification 7.3 EMC and Environmental Type Tests Test Description Test Levels Severity Levels IEC 60068-2-30 Humidity (Damp Test Db 95% (non- — Heat, Cyclic) condensing), 55 °C (131 °F), 6 cycles IEC 60255-21-1 Vibration 2g @ 10-150 Hz Class 2 IEC 60255-21-2 Shock 30 g @ 11 ms Class 2...
  • Page 58 For more information Siemens RUGGEDCOM https://www.siemens.com/ruggedcom Industry Online Support (service and support) https://support.industry.siemens.com Industry Mall https://mall.industry.siemens.com Siemens Canada Ltd. Digital Industries Process Automation 300 Applewood Crescent Concord, Ontario, L4K 4E5 Canada © 2023 Siemens Canada Ltd. Subject to change...

Table of Contents