SIMATIC NET
Rugged Ethernet Switches
RUGGEDCOM RSG2300
Edition
01/2020
https://www.siemens.com

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC NET RUGGEDCOM RSG2300

  • Page 1 Installation Manual SIMATIC NET Rugged Ethernet Switches RUGGEDCOM RSG2300 Edition 01/2020 https://www.siemens.com...
  • Page 2 Preface Introduction Installing the Device SIMATIC NET Device Management Rugged Ethernet Switches RUGGEDCOM RSG2300 Communication Ports Technical Specifications Installation Manual Certification 01/2020 C79000-G8976-1046-15...
  • Page 3: Legal Information

    Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommend- ed or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 4: Table Of Contents

    Preface ............................v Related Documents ......................... v Accessing Documentation ....................... v Training ........................... v Customer Support ........................vi Contacting Siemens ........................ vi Introduction ........................... 1 Feature Highlights ....................1 Description ......................2 Required Tools and Materials ................. 3 Decommissioning and Disposal ................4 Cabling Recommendations ..................
  • Page 5 Table of Contents Technical Specifications ...................... 31 Power Supply Specifications ................31 Failsafe Relay Specifications ................31 Supported Networking Standards ................ 31 Copper Ethernet Port Specifications ..............32 Fiber Optic Ethernet Port Specifications ............... 33 Operating Environment ..................34 Mechanical Specifications ..................35 Dimension Drawings ...................
  • Page 6: Preface

    Siemens Customer Support. Training Siemens offers a wide range of educational services ranging from in-house training of standard courses on networking, Ethernet switches and routers, to on-site cus- tomized courses tailored to the customer's needs, experience and application.
  • Page 7: Customer Support

    Preface Customer Support Customer Support Customer support is available 24 hours, 7 days a week for all Siemens customers. For technical support or general information, contact Siemens Customer Support through any of the following methods: Online Visit http://www.siemens.com/automation/support-request to submit a Support Request (SR) or check on the status of an existing SR.
  • Page 8: Introduction

    Introduction The RUGGEDCOM RSG2300 is a rugged, fully managed, modular Ethernet switch specifically designed to operate reliably in electrically harsh and climatically de- manding utility substation, railway and industrial environments. The RUGGEDCOM RSG2300’s superior rugged hardware design coupled with the embedded Rugged Operating System (ROS) provides improved system reliability and advanced cyber security and networking features, making it ideally suited for creating Ethernet net- works for mission-critical, real-time, control applications.
  • Page 9: Description

    Introduction 1.2 Description • Pluggable Optic module support: SFP, GBIC • Multiple connector types (ST, MTRJ, LC, SC) Rated for Reliability in Harsh Environments • Immunity to EMI and heavy electrical surges • Zero-Packet-Loss™ technology • -40 to 85 °C (-40 to 185 °F) operating temperature (no fans) •...
  • Page 10: Required Tools And Materials

    Introduction 1.3 Required Tools and Materials Communication Ports Ports for communicating with other devices or accessing the RUGGEDCOM RUGGEDCOM RSG2300 operating system are de- scribed in "Communication Ports (Page 23)". Port Status Indicator LEDs Port status indicator LEDs indicate the operational status of each port, dependent on the currently selected mode.
  • Page 11: Decommissioning And Disposal

    Siemens also does not recommend using copper Ethernet ports to interface with de- vices in the field across distances that could produce high levels of ground potential rise (i.e.
  • Page 12: Supported Fiber Optic Cables

    Introduction 1.5.3 Supported Fiber Optic Cables The following table summarizes the relevant cabling standards: Cabling 1000Base- Required Action Category TX Compliant < 5 New wiring infrastructure required. Verify TIA/EIA-568-A compliance. No action required. New installations should be designed with Cate- gory 5e or higher. No action required.
  • Page 13 Introduction 1.5.3 Supported Fiber Optic Cables RUGGEDCOM RSG2300 Installation Manual, 01/2020, C79000-G8976-1046-15...
  • Page 14: Installing The Device

    This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void. Changes or modifications not expressly approved by Siemens AG could invalidate specifications, test results, and agency approvals, and void the user's authority to operate the equipment.
  • Page 15: Unpacking The Device

    Visually inspect each item in the package for any physical damage. Verify all items are included. NOTICE If any item is missing or damaged, contact Siemens for assistance. Mounting the Device The RUGGEDCOM RSG2300 is designed for maximum mounting and display flexibili- ty.
  • Page 16: Mounting The Device To A Rack

    Installing the Device 2.3.1 Mounting the Device to a Rack 2.3.1 Mounting the Device to a Rack The RUGGEDCOM RSG2300 can be secured to a standard 48 cm (19 in) rack using separately purchased rack mount adapters. The adapters can be installed at the front or rear of the chassis.
  • Page 17: Mounting The Device On A Din Rail

    Installing the Device 2.3.2 Mounting the Device on a DIN Rail Make sure the rack mount adapters are installed on the correct side of the chas- sis. • To make the modules and ports accessible, install the rack mount adapters at the rear of the chassis •...
  • Page 18: Mounting The Device To A Panel

    Installing the Device 2.3.3 Mounting the Device to a Panel To mount the device to a DIN rail, do the following: Align the adapters with the DIN rails and slide the device into place. Panel/DIN Rail Adapter DIN Rail Screw Figure 2.2 DIN Rail Mounting Install one of the supplied screws on either side of the device to secure the adapters to the DIN rails.
  • Page 19: Connecting The Failsafe Alarm Relay

    Installing the Device 2.4 Connecting the Failsafe Alarm Relay To mount the device to a panel, do the following: Place the device against the panel and align the adapters with the mounting holes. Screw Panel/DIN Rail Adapter Figure 2.3 Panel Mounting Install the supplied screws to secure the adapters to the panel. Connecting the Failsafe Alarm Relay The failsafe relay can be configured to latch based on alarm conditions.
  • Page 20: Connecting Power

    Installing the Device 2.5 Connecting Power Normally Open Common Normally Closed Figure 2.4 Failsafe Alarm Relay Wiring Connecting Power The RUGGEDCOM RSG2300 supports a single or dual redundant AC and/or DC power supplies. The RUGGEDCOM RSG2300 can be equipped with either a screw-type or pluggable terminal block, which provides power to both power supplies .
  • Page 21: Connecting Ac Or Dc Power

    Installing the Device 2.5.1 Connecting AC or DC Power • It is recommended to provide a separate circuit breaker for each power supply module. • Equipment must be installed according to applicable local wiring codes and stan- dards. 2.5.1 Connecting AC or DC Power To connect a single high AC, high DC or low DC power supply to the device, do the following: CAUTION...
  • Page 22 Installing the Device 2.5.1 Connecting AC or DC Power Connect the positive wire from the power source to the positive/live (+/L) termi- nal on the terminal block. Screw-Type Terminal Block Pluggable Terminal Block Jumper Positive/Live (+/L) Terminal Negative/Neutral (-/N) Terminal (-/N) Surge Ground Terminal Chassis Ground Terminal Figure 2.5...
  • Page 23: Wiring Examples

    Installing the Device 2.5.2 Wiring Examples Using a #6 ring lug and #6-32 screw, secure the ground terminal on the power source to the chassis ground terminal on the device. Make sure the lug is tight- ened to 1.7 N·m (15 lbf·in). Stainless Steel Stud #6-32 Screw #6 Ring Lug...
  • Page 24 Installing the Device 2.5.2 Wiring Examples Figure 2.7 Single AC Power Supply Figure 2.8 Single DC Power Supply RUGGEDCOM RSG2300 Installation Manual, 01/2020, C79000-G8976-1046-15...
  • Page 25 Installing the Device 2.5.2 Wiring Examples Figure 2.9 Dual AC Power Supply Figure 2.10 Dual DC Power Supply RUGGEDCOM RSG2300 Installation Manual, 01/2020, C79000-G8976-1046-15...
  • Page 26 Installing the Device 2.5.2 Wiring Examples Figure 2.11 Dual AC/DC Power Supply RUGGEDCOM RSG2300 Installation Manual, 01/2020, C79000-G8976-1046-15...
  • Page 27 Installing the Device 2.5.2 Wiring Examples RUGGEDCOM RSG2300 Installation Manual, 01/2020, C79000-G8976-1046-15...
  • Page 28: Device Management

    Device Management This section describes how to connect to and manage the device. Connecting to the Device The following describes the various methods for accessing the RUGGEDCOM RSG2300 console and Web interfaces on the device. For more detailed instructions, refer to the RUGGEDCOM RSG2300 User Guide for the RUGGEDCOM RSG2300. RS232 Console Port Connect a workstation directly to the RS232 console port to access the boot-time control and RUGGEDCOM RSG2300 interfaces.
  • Page 29: Configuring The Device

    Device Management 3.2 Configuring the Device Name Description Comment RJ45 Male DB9 Female Ring Indicator   The DSR, DCD and DTR pins are connected together internally. The CTS and RTS pins are connected together internally. RI is not connected. Communication Ports Connect any of the available Ethernet ports on the device to a management switch and access the RUGGEDCOM RSG2300 console and Web interfaces via the device's IP address.
  • Page 30: Communication Ports

    Communication Ports The RUGGEDCOM RSG2300 can be equipped with various types of communication ports to enhance its abilities and performance. Module Assignment Figure 4.1 Module Assignment Each type of module has a specific location in the RUGGEDCOM RSG2300 chassis: • Slots 1 and 2 support any combination of two-port fiber or copper Ethernet mod- ules up to 100 Mbps •...
  • Page 31: Copper Ethernet Ports

    Communication Ports 4.1 Copper Ethernet Ports   LED State Description Yellow (Solid) Link established Yellow (Blinking) Link activity No link detected Port LED Figure 4.2 Port LEDs Copper Ethernet Ports The RUGGEDCOM RSG2300 supports several 10/100/1000Base-TX Ethernet ports that allow connection to standard Category 5 (CAT-5) unshielded twisted-pair (UTP) ca- bles with either RJ45 male connectors.
  • Page 32: Fiber Optic Ethernet Ports

    Communication Ports 4.2 Fiber Optic Ethernet Ports Name Description 10/100Base-TX 1000Base-TX BI_DB+ Transmit Data+ or Bi- Directional Pair B+ Reserved (Do Not Connect) BI_DC+ Transmit Data+ or Bi- Directional Pair C+ Reserved (Do Not Connect) BI_DC- Receive Data- or Bi- Directional Pair C- BI_DB- Transmit Data- or Bi- Directional Pair B-...
  • Page 33: Sfp Transceivers

    RUGGEDCOM SFP Transceiver Catalog [https://support.indus- mation, refer to the try.siemens.com/cs/ww/en/view/109482309] NOTICE Only use SFP transceivers approved by Siemens for RUGGEDCOM products. Siemens accepts no liability as a result of performance issues related in whole or in part to third-party components. SFP Transceiver...
  • Page 34: Gbic Optic Ethernet Ports

    To install a GBIC optical port, do the following: CAUTION Electrical hazard – risk of damage to equipment Use only components certified by Siemens with RUGGEDCOM products. Damage to the module and device may occur if compatibility and reliability have not been prop- erly assessed.
  • Page 35 Communication Ports 4.4.1 Installing a GBIC Optical Port Remove the port from its packaging. CAUTION Mechanical hazard – risk of component damage GBIC optical ports are designed to insert in only one orientation. Do not force the port into the module. Remove the dust plug from the socket and store for future use.
  • Page 36: Removing A Gbic Optical Port

    Communication Ports 4.4.2 Removing a GBIC Optical Port 4.4.2 Removing a GBIC Optical Port To remove an GBIC optical port, do the following: CAUTION Electrical hazard – risk of damage to equipment Make sure all electrostatic energy is dissipated before performing installing or re- moving components from the device.
  • Page 37 Communication Ports 4.4.2 Removing a GBIC Optical Port RUGGEDCOM RSG2300 Installation Manual, 01/2020, C79000-G8976-1046-15...
  • Page 38: Technical Specifications

    Technical Specifications This section details the specifications and operating conditions of the device. Power Supply Specifications The RUGGEDCOM RSG2300 can be equipped with the following power supplies: CAUTION Electrical hazard – risk of damage to the device Make sure power input to the device is within the specified input range. Power Sup- Input Range Internal Fuse...
  • Page 39: Copper Ethernet Port Specifications

    Note • Maximum segment length is greatly dependent on factors such as fiber quality, and the number of patches and splices. Consult a Siemens sales associate when determining maximum segment distances. • All optical power numbers are listed as dBm averages.
  • Page 40: Fiber Optic Ethernet Port Specifications

    14.2 Typical. Typical distance. The maximum distance is greatly dependent on factors such as cable type, the number of connectors and number of splices. Consult a Siemens sales associates when determining maximum distances. Fast Ethernet (10/100 Mbps) Optical Specifications Mode...
  • Page 41: Operating Environment

    All optical power numbers are listed as dBm averages. Typical distance. The maximum segment length is greatly dependent on factors such as fiber quality, and the number of patches and splices. Consult a Siemens sales associates when determining maximum segment distances. GBIC Gigabit (1 Gbps) Transceiver Specifications Note GBIC transceivers have a temperature range of -40 to 85 °C (-40 to 185 °F), unless...
  • Page 42: Mechanical Specifications

    Technical Specifications 5.7 Mechanical Specifications Operating temperature may vary based on the limitations of installed SFPs. Refer to the RUGGEDCOM SFP Transceivers Catalog for SFP temperature ratings. Non-condensing Mechanical Specifications Weight 5.2 kg (11.5 lbs) Ingress Protection IP20 Enclosure 18 AWG Galvanized Steel Dimension Drawings Note All dimensions are in millimeters, unless otherwise stated.
  • Page 43 Technical Specifications 5.8 Dimension Drawings 438.15 Figure 5.1 Overall Dimensions RUGGEDCOM RSG2300 Installation Manual, 01/2020, C79000-G8976-1046-15...
  • Page 44 Technical Specifications 5.8 Dimension Drawings 32.77 21.08 11.68 479.29 478.79 STATUS ALARM DUPLEX POWER1 SPEED POWER2 CONSOL E 57600-N-8-1 MODE 4.57 Figure 5.2 Rack Mount Dimensions RUGGEDCOM RSG2300 Installation Manual, 01/2020, C79000-G8976-1046-15...
  • Page 45 Technical Specifications 5.8 Dimension Drawings 11.7 10.4 STATUS ALARM DUPLEX POWER1 SPEED POWER2 CONSOL E 57600-N-8-1 MODE 476.3 486.4 Figure 5.3 Panel and DIN Rail Mount Dimensions RUGGEDCOM RSG2300 Installation Manual, 01/2020, C79000-G8976-1046-15...
  • Page 46: Certification

    UL 60950-1 Information Technology Equipment – Safety Part 1: General Requirements 6.1.2 European Union (EU) This device is declared by Siemens AG to comply with essential requirements and other relevant provisions of the following EU directives: • EN 60950-1 Information Technology Equipment – Safety – Part 1: General Requirements •...
  • Page 47: Fcc

    Methods of Measurement The device is marked with a CE marking and can be used throughout the European community. A copy of the CE Declaration of Conformity is available from Siemens AG. For contact information, refer to "Contacting Siemens (Page vi)".
  • Page 48: Iso

    6.1.8 RoHS This device is declared by Siemens AG to meet the requirements of the following Ro- HS (Restriction of Hazardous Substances) directives for the restricted use of certain hazardous substances in electrical and electronic equipment: •...
  • Page 49: Other Approvals

    Certification 6.1.9 Other Approvals 6.1.9 Other Approvals This device meets the requirements of the following additional standards: • IEEE 1613 IEEE Standard Environmental and Testing Requirements for Communications Networking Devices in Electric Power Substations • IEC 61000-6-2 Electromagnetic Compatibility (EMC) – Part 6-2: Generic Standards – Immunity for Industrial Environments •...
  • Page 50 Certification 6.2 EMC and Environmental Type Tests Test Description Test Levels Severity Levels 1000 A/m for 1 s IEC 61000-4-11 Voltage Dips AC Power Ports 30% for 1 period   and Interrupts 60% for 50 periods 100% for 5 periods 100% for 50 periods IEC 61000-4-12 Damped...
  • Page 51: Environmental Type Tests

    Certification 6.2 EMC and Environmental Type Tests Description Test Levels DC Power Ports 2.5 kV Common 1 kV differential mode @ 1 MHz AC Power Ports 2.5 kV Common 1 kV differential mode @ 1 MHz HV Impulse Signal Ports 5 kV (Fail-Safe Relay Output) DC Power Ports 5 kV AC Power Ports...
  • Page 52: Further Information

    Further Information Siemens RUGGEDCOM https://www.siemens.com/ruggedcom Industry Online Support (service and support) https://support.industry.siemens.com Industry Mall https://mall.industry.siemens.com Siemens AG Digital Industry Process Automation Postfach 48 48 90026 NÜRNBERG GERMANY...