Siemens RUGGEDCOM RMC8388 Installation Manual
Siemens RUGGEDCOM RMC8388 Installation Manual

Siemens RUGGEDCOM RMC8388 Installation Manual

Simatic net rugged ethernet switches

Advertisement

Quick Links

Edition
11/2022
Installation Manual
SIMATIC NET
Rugged Ethernet Switches
RUGGEDCOM RMC8388
https://www.siemens.com/ruggedcom

Advertisement

Table of Contents
loading

Summary of Contents for Siemens RUGGEDCOM RMC8388

  • Page 1 Edition 11/2022 Installation Manual SIMATIC NET Rugged Ethernet Switches RUGGEDCOM RMC8388 https://www.siemens.com/ruggedcom...
  • Page 2 Preface Introduction Installing the Device SIMATIC NET Device Management Rugged Ethernet Switches RUGGEDCOM RMC8388 Communication Ports Technical Specifications Installation Manual Certification 11/2022 C79000-G8976-1188-05...
  • Page 3 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 4: Table Of Contents

    Accessing Documentation ....................... v Registered Trademarks ......................v Warranty ..........................vi Training ..........................vi Customer Support ........................vi Contacting Siemens ....................... vii Introduction ........................... 1 Feature Highlights ....................1 Description ......................2 Required Tools and Materials ................. 4 Decommissioning and Disposal ................4 Supported Fiber Optic Cables ................
  • Page 5 European Union (EU) ..................32 6.1.4 FDA/CDRH ......................32 6.1.5 ISED ........................32 6.1.6 ISO ........................33 6.1.7 ACMA ........................33 6.1.8 RoHS ........................33 6.1.9 Other Approvals ....................34 EMC and Environmental Type Tests ..............34 RUGGEDCOM RMC8388 Installation Manual, 11/2022, C79000-G8976-1188-05...
  • Page 6: Preface

    SIMATIC NET Glossary The SIMATIC NET Glossary describes special terms that may be used in this document. The glossary is available online via Siemens Industry Online Support (SIOS) at: https://support.industry.siemens.com/cs/ww/en/view/50305045 Accessing Documentation The latest user documentation for RUGGEDCOM RMC8388 is available online at https://support.industry.siemens.com.
  • Page 7: Warranty

    Preface Warranty Warranty Siemens warrants this product for a period of five (5) years from the date of purchase, conditional upon the return to factory for maintenance during the warranty term. This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void.
  • Page 8: Contacting Siemens

    Call a local hotline center to submit a Support Request (SR). To locate a local hotline center, visit https://w3.siemens.com/aspa_app/?lang=en. Mobile App Install the Industry Online Support app by Siemens AG on any Android, Apple iOS or Windows mobile device and be able to: •...
  • Page 9 Preface Contacting Siemens viii RUGGEDCOM RMC8388 Installation Manual, 11/2022, C79000-G8976-1188-05...
  • Page 10: Introduction

    Introduction The RUGGEDCOM RMC8388 is a rugged, small form factor time converter designed to operate in electrically harsh environments with widely varying climatic and environmental conditions such as those found in utility substations. Designed and verified to withstand extreme temperatures, vibrations and shock, the RUGGEDCOM RMC8388 offers exceptional reliability.
  • Page 11: Description

    1024-bit RSA encryption for key management and key exchange Description The RUGGEDCOM RMC8388 features various ports, controls and indicator LEDs for connecting, configuring and troubleshooting the device. The final device configuration is determined during the ordering process. The following describes the major options available.
  • Page 12 BNC Port – AM IN Copper Ethernet Port with LINK/ACT LED Copper FastConnect Ethernet Port with LINK/ACT LED Fiber Optic Ethernet Port with LINK/ACT LED Figure 1.1 RUGGEDCOM RMC8388 POWER LED Illuminates when power is being supplied to the device. State Description...
  • Page 13: Required Tools And Materials

    Introduction 1.3 Required Tools and Materials Required Tools and Materials The following tools and materials are required to install the RUGGEDCOM RMC8388: Tools/Materials Purpose AC or DC power cord (16 AWG) For connecting power to the device. Shielded coaxial cables For connecting the device to the network.
  • Page 14: Precision Time Protocol (Ptp) Support

    Precision Time Protocol (PTP) and Network Time Protocol (NTP), and to synchronize with an external IRIG-B source. The RUGGEDCOM RMC8388 features BNC ports for AM IN, OUT and TTL OUT. It also includes a SYNC LED to indicate when synchronization has been achieved.
  • Page 15: Ieee 1588 Support

    "IEEE 1588 Support" (Page IRIG-B IN • IRIG-B IN is supported only by the C variant of RUGGEDCOM RMC8388. It inputs IRIG Standard 200-04 compliant signals from synchronized external devices. 1.6.2 IEEE 1588 Support RUGGEDCOM RMC8388 supports various IEEE 1588 time synchronization capabilities.
  • Page 16 (IS) required to drive the connected devices is less than the maximum drive current the source can provide, and verifying that the load voltage (VL) the connected devices see is greater than the minimum required voltage. RUGGEDCOM RMC8388 Installation Manual, 11/2022, C79000-G8976-1188-05...
  • Page 17 Introduction 1.6.3 AM and TTL Outputs RUGGEDCOM RMC8388 Installation Manual, 11/2022, C79000-G8976-1188-05...
  • Page 18: Installing The Device

    This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void. Changes or modifications not expressly approved by Siemens Canada Ltd. could invalidate specifications, test results, and agency approvals, and void the user's authority to operate the equipment.
  • Page 19: General Procedure

    Visually inspect each item in the package for any physical damage. Verify all items are included. Note If any item is missing or damaged, contact Siemens for assistance. Mounting the Device The RUGGEDCOM RMC8388 is designed for maximum mounting and display flexibility.
  • Page 20: Mounting The Device On A Din Rail

    2.3.1 Mounting the Device on a DIN Rail The RUGGEDCOM RMC8388 can be ordered with a DIN rail adapter preinstalled on the back of the chassis. Use the adapter to mount the device to a standard 35 mm (1.4 in) IEC/EN 60715 or TS35 DIN rail.
  • Page 21 Removing the Device To remove the device from a DIN rail, do the following: Insert a flathead screwdriver into the slot of the sliding release and move it down. RUGGEDCOM RMC8388 Installation Manual, 11/2022, C79000-G8976-1188-05...
  • Page 22: 2.3.2 Mounting The Device To A Panel

    2.3.2 Mounting the Device to a Panel For panel installations, the RUGGEDCOM RMC8388 can be equipped with panel adapters that allow the device to be attached to a panel using screws. To mount the device to a panel, do the following: Loosen the screws for the panel adapters located at the top and bottom of the device.
  • Page 23: Connecting Power

    Using two #6-32 screws for each adapter, secure the device to the panel. Connecting Power The RUGGEDCOM RMC8388 supports a single integrated high AC/DC power supply, a 48 V low DC power supply, and a 24 V low DC power supply.
  • Page 24: 2.4.1 Connecting High Ac/Dc Power

    Connect the negative wire from the power source to the negative/neutral (-/N) terminal on the terminal block. Using a braided wire or other appropriate grounding wire, connect the surge ground terminal to the chassis ground connection. The surge ground terminal RUGGEDCOM RMC8388 Installation Manual, 11/2022, C79000-G8976-1188-05...
  • Page 25: 2.4.2 Connecting Low Dc Power

    2.4.2 Connecting Low DC Power The RUGGEDCOM RMC8388 supports a single low DC power supply with dual power supply inputs. The use of both power supply inputs is recommended to provide input power redundancy. To connect a low DC power supply to the device, do the following: NOTICE Electrical hazard –...
  • Page 26 The surge ground terminal is used as the ground conductor for all surge and transient suppression circuitry internal to the unit. Connect the ground terminal on the power source to the chassis ground terminal on the device. RUGGEDCOM RMC8388 Installation Manual, 11/2022, C79000-G8976-1188-05...
  • Page 27 Installing the Device 2.4.2 Connecting Low DC Power RUGGEDCOM RMC8388 Installation Manual, 11/2022, C79000-G8976-1188-05...
  • Page 28: Device Management

    Serial DB9 Console Port Reserved (Do Not Connect) Connected internally. Communication Ports Connect any of the available Ethernet ports on the device to a management switch and access the RUGGEDCOM ROS console and Web interfaces via the RUGGEDCOM RMC8388 Installation Manual, 11/2022, C79000-G8976-1188-05...
  • Page 29: Configuring The Device

    Device Management 3.2 Configuring the Device device's IP address. The factory default IP address for the RUGGEDCOM RMC8388 is https://192.168.0.1. For more information about available ports, refer to "Communication Ports" (Page 21). Configuring the Device Once the device is installed and connected to the network, it must be configured.
  • Page 30: Communication Ports

    Both ports provide IRIG-B Pulse Width Modulation (PWM), Pulse Per Second (1PPS), or Siemens' Pulse Per X (PPX) output. PPX allows users to set the pulse interval, pulse width and start time. The signal format is independently configurable for each port via RUGGEDCOM RUGGEDCOM RMC8388.
  • Page 31: Leds

    For technical specifications related to the BNC ports, refer to "IRIG-B Specifications" (Page 26). LEDs The RUGGEDCOM RMC8388 has two LEDs on the front panel. The POWER LED indicates the status of the device: POWER LED SYNC LED Figure 4.2 LEDs •...
  • Page 32: Copper Ethernet Port (If Equipped)

    Copper Ethernet Port (If Equipped) The 100Base-TX copper Ethernet port features a standard RJ-45 connector or Siemens's FastConnect RJ-45 connector, both of which are directly connected to the chassis ground. Standard Category 5 (CAT-5) unshielded twisted-pair (UTP) or shielded twisted-pair (STP) cables can be used to connect to this port.
  • Page 33 Siemens also does not recommend using copper Ethernet ports to interface with devices in the field across distances that could produce high levels of ground potential rise (i.e. greater than 2500 V), during line-to-ground fault conditions.
  • Page 34: Technical Specifications

    This section provides important technical specifications related to the device and available modules. Power Supply Specifications The RUGGEDCOM RMC8388 includes one of the following internal power supplies: NOTICE Electrical hazard – risk of damage to the device Do not exceed the maximum input voltage specified for the 24 or 48 VDC power supplies.
  • Page 35: Fiber Optic Ethernet Port Specifications

    3 dBm. To convert from peak to average, subtract 3 dBm. • Maximum segment length is greatly dependent on factors such as fiber quality, and the number of patches and splices. Consult a Siemens Sales associate when determining maximum segment distances. Speed...
  • Page 36: Operating Environment

    > 3.5 kΩ Carrier Frequency 1 kHz Modulation Depth 3:1±10% Operating Environment The RUGGEDCOM RMC8388 is rated to operate under the following environmental conditions. Ambient Operating -40 to 85 °C (-40 to 185 °F) Temperature Ambient Storage Temperature -40 to 85 °C (-40 to 185 °F)
  • Page 37 Technical Specifications 5.7 Dimension Drawings 65.1 132.5 116.6 Figure 5.1 Overall Dimensions 57.2 11.2 101.6 78.7 4 (4x) Figure 5.2 Panel Mount Dimensions RUGGEDCOM RMC8388 Installation Manual, 11/2022, C79000-G8976-1188-05...
  • Page 38 Technical Specifications 5.7 Dimension Drawings 142.1 126.2 Figure 5.3 DIN Rail Mount Dimensions RUGGEDCOM RMC8388 Installation Manual, 11/2022, C79000-G8976-1188-05...
  • Page 39 Technical Specifications 5.7 Dimension Drawings RUGGEDCOM RMC8388 Installation Manual, 11/2022, C79000-G8976-1188-05...
  • Page 40: Certification

    Information Technology Equipment – Safety – Part 1: General Requirements (Bi- National standard, with UL 62368-1) • UL 62368-1:2014/R1:2011-12 Information Technology Equipment – Safety – Part 1: General Requirements A copy of the TUV Certificate is available via Siemens Industry Online Support at https://support.industry.siemens.com/cs/ww/en/view/109756584. RUGGEDCOM RMC8388 Installation Manual, 11/2022, C79000-G8976-1188-05...
  • Page 41: European Union (Eu)

    Title 21 Code of Federal Regulations (CFR) – Chapter I – Sub-chapter J – Radiological Health 6.1.5 ISED This device is declared by Siemens Canada Ltd. to meet the requirements of the following ISED (Innovation Science and Economic Development Canada) standard: • CAN ICES-3 (A)/NMB-3 (A)
  • Page 42: Iso

    Support at https://support.industry.siemens.com/cs/ww/en/view/89855782. 6.1.8 RoHS This device is declared by Siemens Canada Ltd. to meet the requirements of the following RoHS (Restriction of Hazardous Substances) directives for the restricted use of certain hazardous substances in electrical and electronic equipment: •...
  • Page 43: 6.1.9 Other Approvals

    • IEC 61000-6-2 Electromagnetic Compatibility (EMC) – Part 6-2: Generic Standards – Immunity for Industrial Environments EMC and Environmental Type Tests The RUGGEDCOM RMC8388 has passed the following EMC and environmental tests. IEC 61850-3 Type Tests Test Description Test Levels...
  • Page 44   Ports AC Power 2 kVDC   Ports HV Impulse Signal Ports 5 kV  (Fail-Safe   Relay Output) DC Power 5 kV   Ports AC Power 5 kV   Ports Siemens specified severity level. RUGGEDCOM RMC8388 Installation Manual, 11/2022, C79000-G8976-1188-05...
  • Page 45 Test Db 6 cycles at 55 °C (131   (Damp °F) and 95% relative Heat, Cyclic) humidity (non-condensing) IEC 60068-2-31 Free Fall Procedure 1, 2 falls from a   height of 250 mm (9.8 in) RUGGEDCOM RMC8388 Installation Manual, 11/2022, C79000-G8976-1188-05...
  • Page 46 2 g @ 10-150 Hz Class 2 IEC 60255-21-2 Shock 30 g @ 11 ms Class 2 IEC 60255-21-3 Seismic Level 2 Method A IEC 60870--2-2 Static Load 5 kPa for 1 min   RUGGEDCOM RMC8388 Installation Manual, 11/2022, C79000-G8976-1188-05...
  • Page 47 Certification 6.2 EMC and Environmental Type Tests RUGGEDCOM RMC8388 Installation Manual, 11/2022, C79000-G8976-1188-05...
  • Page 48 For more information Siemens RUGGEDCOM https://www.siemens.com/ruggedcom Industry Online Support (service and support) https://support.industry.siemens.com Industry Mall https://mall.industry.siemens.com Siemens Canada Ltd. Digital Industries Process Automation 300 Applewood Crescent Concord, Ontario, L4K 4E5 Canada © 2022 Siemens Canada Ltd. Subject to change...

This manual is also suitable for:

Simatic net ruggedcom rmc8388

Table of Contents