TECHNICAL DATA & SERVICE MANUAL
R410A Models
Model No.
Indoor Units
Indoor
Type
Units Type
U1
4-Way Cassette
S-36PU1E5A S-45PU1E5A S-50PU1E5A S-60PU1E5A S-71PU1E5A S-100PU1E5A S-125PU1E5A S-140PU1E5A
T2 Ceiling
S-36PT2E5A S-45PT2E5A S-50PT2E5A S-60PT2E5A S-71PT2E5A S-100PT2E5A
K1
Wall Mounted
S-36PK1E5A S-45PK1E5A S-50PK1E5A S-60PK1E5A S-71PK1E5A
Low Silhouette
F1
S-36PF1E5A S-45PF1E5A S-50PF1E5A S-60PF1E5A S-71PF1E5A S-100PF1E5A S-125PF1E5A S-140PF1E5A
Ducted
N1
Ducted
S-36PN1E5A S-45PN1E5A S-50PN1E5A S-60PN1E5A S-71PN1E5A S-100PN1E5A S-125PN1E5A S-140PN1E5A
4-Way
Y2
S-36PY2E5A S-45PY2E5A S-50PY2E5A
Cassette 60 x 60
Outdoor Units
Type
Outdoor Units Type
Single Split (1-phase)
PE1
Single Split (3-phase)
Single Split (1-phase)
PEY1
Single Split (3-phase)
85464849331002
Indoor Unit
4-Way Cassette
4-Way Cassette 60 x 60
Ceiling
Wall Mounted
Low Silhouette Ducted
Ducted
36
45
50
U-50PE1E5
50
60
71
60
71
U-60PE1E5A U-71PE1E5A U-100PE1E5A U-125PE1E5A U-140PE1E5A
U-71PE1E8A U-100PE1E8A U-125PE1E8A U-140PE1E8A
U-60PEY1E5
U-71PEY1E5 U-100PEY1E5 U-125PEY1E5
Order No. SBPAC1403009CE 
Outdoor Unit
100
125
S-125PT2E5A S-140PT2E5A
S-100PK1E5A
100
125
U-100PEY1E8 U-125PEY1E8
REFERENCE NO.
140
140
U-140PEY1E8
SM830231-02

Advertisement

loading

Summary of Contents for Panasonic S-36PU1E5A

  • Page 1 Ducted R410A Models Model No. Indoor Units Indoor Type Units Type 4-Way Cassette S-36PU1E5A S-45PU1E5A S-50PU1E5A S-60PU1E5A S-71PU1E5A S-100PU1E5A S-125PU1E5A S-140PU1E5A T2 Ceiling S-36PT2E5A S-45PT2E5A S-50PT2E5A S-60PT2E5A S-71PT2E5A S-100PT2E5A S-125PT2E5A S-140PT2E5A Wall Mounted S-36PK1E5A S-45PK1E5A S-50PK1E5A S-60PK1E5A S-71PK1E5A S-100PK1E5A –...
  • Page 2: Please Read Before Starting

    IMPORTANT! • Provide a power outlet exclusively for each unit, and full disconnection means Please Read Before Starting having a contact separation in all poles This air conditioner must be installed by the sales dealer must be incorporated in the fixed wiring or installer.
  • Page 3 When Connecting Refrigerant Tubing WARNING • This product must not be modified WARNING or disassembled under any • When performing piping work do not circumstances. Modified or mix air except for specified refrigerant disassembled unit may cause fire, (R410A) in refrigeration cycle. It electric shock or injury.
  • Page 4: Check Of Density Limit

    Check of Density Limit The standards for minimum room volume are as follows. (1) No partition (shaded portion) The room in which the air conditioner is to be installed requires a design that in the event of refrigerant gas leaking out, its density will not exceed a set limit. The refrigerant (R410A), which is used in the air conditioner, is safe, without the toxicity or combustibility of ammonia, and is not restricted by laws imposed to protect the ozone layer.
  • Page 5 IMPORTANT INFORMATION REGARDING THE REFRIGERANT USED This product contains fluorinated greenhouse gases covered by the Kyoto Protocol. Do not vent gases into the atmosphere. Refrigerant type: R410A value: 1975 GWP = global warming potential Periodical inspections for refrigerant leaks may be required depending on European or local legislation. Please contact your local dealer for more information.
  • Page 6: Single-Phase

    Combination of Indoor and Outdoor Units Single-phase S-36PU1E5A x2 S-45PU1E5A x3 S-50PU1E5A S-60PU1E5A S-71PU1E5A S-100PU1E5A S-125PU1E5A S-140PU1E5A U-71PE1E5A U-125PE1E5A U-50PE1E5 U-60PE1E5A U-71PE1E5A U-100PE1E5A U-125PE1E5A U-140PE1E5A S-36PU1E5A x3 S-50PU1E5A x2 S-60PU1E5A x2 S-71PU1E5A x2 U-100PE1E5A U-100PE1E5A U-125PE1E5A U-140PE1E5A S-36PU1E5A x4 S-50PU1E5A x3...
  • Page 7 Combination of Indoor and Outdoor Units 3-phase S-36PU1E5A x2 S-45PU1E5A x3 S-50PU1E5A x2 S-60PU1E5A x2 S-71PU1E5A S-100PU1E5A S-125PU1E5A S-140PU1E5A U-71PE1E8A U-125PE1E8A U-100PE1E8A U-125PE1E8A U-71PE1E8A U-100PE1E8A U-125PE1E8A U-140PE1E8A S-36PU1E5A x3 S-50PU1E5A x3 S-71PU1E5A x2 U-100PE1E8A U-140PE1E8A U-140PE1E8A S-36PU1E5A x4 U-125PE1E8A S-36PT2E5A x2...
  • Page 8 Combination of Indoor and Outdoor Units PEY1 Single-phase S-36PU1E5A x2 S-50PU1E5A x2 S-60PU1E5A S-71PU1E5A S-100PU1E5A S-125PU1E5A U-60PEY1E5 U-71PEY1E5 U-100PEY1E5 U-125PEY1E5 U-71PEY1E5 U-100PEY1E5 P141 P142 P143 P145 P146 P147 S-60PU1E5A x2 U-125PEY1E5 P144 S-60PT2E5A S-71PT2E5A S-100PT2E5A S-125PT2E5A S-36PT2E5A x2 S-50PT2E5A x2...
  • Page 9 1. SPECIFICATIONS 1-1. Unit Specifications ....................1. 4-Way Cassette Type (U1) ....................... 2. Ceiling Type (T2) ..........................1-28 3. Wall Mounted Type (K1) ........................1-54 4. Low Silhouette Ducted Type (F1) ..................... 1-76 5. Ducted Type (N1) ..........................1-102 6. 4-Way Cassette 60 x 60 Type (Y2) ....................1-128 PEY1 1.
  • Page 10 Simultaneous (Twin) -Type 1-1. Unit Specifi cations 6. 4-Way Cassette 60×60 Type S-36PY2E5A×2 / U-71PE1E5A INDOOR MODEL S-36PY2E5A ×2 PANEL MODEL (CZ-KPY3A / CZ-KPY3B) ×2 OUTDOOR MODEL U-71PE1E5A Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14511 / EN14825 / EN12102 ø, Hz 1ø...
  • Page 11 Simultaneous (Triple) -Type 1-1. Unit Specifi cations 6. 4-Way Cassette 60×60 Type S-36PY2E5A×3 / U-100PE1E5A INDOOR MODEL S-36PY2E5A ×3 PANEL MODEL (CZ-KPY3A / CZ-KPY3B) ×3 OUTDOOR MODEL U-100PE1E5A Branch pipe MODEL CZ-P3HPC2BM PERFORMANCE TEST CONDITION ISO5151 / EN14511 / EN14825 / EN12102 ø, Hz 1ø...
  • Page 12 Simultaneous (Double-Twin) -Type 1-1. Unit Specifi cations 6. 4-Way Cassette 60×60 Type S-36PY2E5A×4 / U-125PE1E5A INDOOR MODEL S-36PY2E5A ×4 PANEL MODEL (CZ-KPY3A / CZ-KPY3B) ×4 OUTDOOR MODEL U-125PE1E5A Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14511 / EN14825 / EN12102 ø, Hz 1ø...
  • Page 13 Simultaneous (Triple) -Type 1-1. Unit Specifi cations 6. 4-Way Cassette 60×60 Type S-45PY2E5A×3 / U-125PE1E5A INDOOR MODEL S-45PY2E5A ×3 PANEL MODEL (CZ-KPY3A / CZ-KPY3B) ×3 OUTDOOR MODEL U-125PE1E5A Branch pipe MODEL CZ-P3HPC2BM PERFORMANCE TEST CONDITION ISO5151 / EN14511 / EN14825 / EN12102 ø, Hz 1ø...
  • Page 14 Single -Type 1-1. Unit Specifi cations 6. 4-Way Cassette 60×60 Type S-50PY2E5A / U-50PE1E5 INDOOR MODEL S-50PY2E5A PANEL MODEL CZ-KPY3A / CZ-KPY3B OUTDOOR MODEL U-50PE1E5 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14511 / EN14825 / EN12102 ø, Hz 1ø...
  • Page 15 Simultaneous (Twin) -Type 1-1. Unit Specifi cations 6. 4-Way Cassette 60×60 Type S-50PY2E5A×2 / U-100PE1E5A INDOOR MODEL S-50PY2E5A ×2 PANEL MODEL (CZ-KPY3A / CZ-KPY3B) ×2 OUTDOOR MODEL U-100PE1E5A Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14511 / EN14825 / EN12102 ø, Hz 1ø...
  • Page 16 Simultaneous (Triple) -Type 1-1. Unit Specifi cations 6. 4-Way Cassette 60×60 Type S-50PY2E5A×3 / U-140PE1E5A INDOOR MODEL S-50PY2E5A ×3 PANEL MODEL (CZ-KPY3A / CZ-KPY3B) ×3 OUTDOOR MODEL U-140PE1E5A Branch pipe MODEL CZ-P3HPC2BM PERFORMANCE TEST CONDITION ISO5151 / EN14511 / EN14825 / EN12102 ø, Hz 1ø...
  • Page 17 Simultaneous (Twin) -Type 1-1. Unit Specifi cations 6. 4-Way Cassette 60×60 Type S-36PY2E5A×2 / U-71PE1E8A INDOOR MODEL S-36PY2E5A ×2 PANEL MODEL (CZ-KPY3A / CZ-KPY3B) ×2 OUTDOOR MODEL U-71PE1E8A Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14511 / EN14825 / EN12102 ø, Hz 1ø...
  • Page 18 Simultaneous (Triple) -Type 1-1. Unit Specifi cations 6. 4-Way Cassette 60×60 Type S-36PY2E5A×3 / U-100PE1E8A INDOOR MODEL S-36PY2E5A ×3 PANEL MODEL (CZ-KPY3A / CZ-KPY3B) ×3 OUTDOOR MODEL U-100PE1E8A Branch pipe MODEL CZ-P3HPC2BM PERFORMANCE TEST CONDITION ISO5151 / EN14511 / EN14825 / EN12102 ø, Hz 1ø...
  • Page 19 Simultaneous (Double-Twin) -Type 1-1. Unit Specifi cations 6. 4-Way Cassette 60×60 Type S-36PY2E5A×4 / U-125PE1E8A INDOOR MODEL S-36PY2E5A ×4 PANEL MODEL (CZ-KPY3A / CZ-KPY3B) ×4 OUTDOOR MODEL U-125PE1E8A Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14511 / EN14825 / EN12102 ø, Hz 1ø...
  • Page 20 Simultaneous (Triple) -Type 1-1. Unit Specifi cations 6. 4-Way Cassette 60×60 Type S-45PY2E5A×3 / U-125PE1E8A INDOOR MODEL S-45PY2E5A ×3 PANEL MODEL (CZ-KPY3A / CZ-KPY3B) ×3 OUTDOOR MODEL U-125PE1E8A Branch pipe MODEL CZ-P3HPC2BM PERFORMANCE TEST CONDITION ISO5151 / EN14511 / EN14825 / EN12102 ø, Hz 1ø...
  • Page 21 Simultaneous (Twin) -Type 1-1. Unit Specifi cations 6. 4-Way Cassette 60×60 Type S-50PY2E5A×2 / U-100PE1E8A INDOOR MODEL S-50PY2E5A ×2 PANEL MODEL (CZ-KPY3A / CZ-KPY3B) ×2 OUTDOOR MODEL U-100PE1E8A Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14511 / EN14825 / EN12102 ø, Hz 1ø...
  • Page 22 Simultaneous (Triple) -Type 1-1. Unit Specifi cations 6. 4-Way Cassette 60×60 Type S-50PY2E5A×3 / U-140PE1E8A INDOOR MODEL S-50PY2E5A ×3 PANEL MODEL (CZ-KPY3A / CZ-KPY3B) ×3 OUTDOOR MODEL U-140PE1E8A Branch pipe MODEL CZ-P3HPC2BM PERFORMANCE TEST CONDITION ISO5151 / EN14511 / EN14825 / EN12102 ø, Hz 1ø...
  • Page 23 Simultaneous (Twin) -Type 1-1. Unit Specifi cations PEY1 6. 4-Way Cassette 60×60 Type S-36PY2E5A×2 / U-71PEY1E5 INDOOR MODEL S-36PY2E5A ×2 PANEL MODEL (CZ-KPY3A / CZ-KPY3B) ×2 OUTDOOR MODEL U-71PEY1E5 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14511 / EN14825 / EN12102 ø, Hz 1ø...
  • Page 24 Simultaneous (Twin) -Type 1-1. Unit Specifi cations PEY1 6. 4-Way Cassette 60×60 Type S-50PY2E5A×2 / U-100PEY1E5 INDOOR MODEL S-50PY2E5A ×2 PANEL MODEL (CZ-KPY3A / CZ-KPY3B) ×2 OUTDOOR MODEL U-100PEY1E5 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14511 / EN14825 / EN12102 ø, Hz 1ø...
  • Page 25 Simultaneous (Twin) -Type 1-1. Unit Specifi cations PEY1 6. 4-Way Cassette 60×60 Type S-50PY2E5A×2 / U-100PEY1E8 INDOOR MODEL S-50PY2E5A ×2 PANEL MODEL (CZ-KPY3A / CZ-KPY3B) ×2 OUTDOOR MODEL U-100PEY1E8 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14511 / EN14825 / EN12102 ø, Hz 1ø...
  • Page 26 1-2. Dimensional Data (A) Indoor Units: S-36PY2E5A, S-45PY2E5A, S-50PY2E5A unit: mm (ceiling opening dimension) (suspension bolt pitch) Panel center VIEW A (583) (583) CZ-KPY3A CZ-KPY3B 4-ø3Barring hole Dimension of Fresh air intake duct (field supply) connection port Air intake grille Air outlet Refrigerant piping (liquid pipe) ø6.35 (flared) Refrigerant piping (gas pipe) ø12.7 (flared)
  • Page 27 1-6. Noise Criterion Curves (A) Indoor Units High 4-Way Cassette 60×60 Type MODEL : S-36PY2E5A MODEL : S-45PY2E5A : High 36 dB(A) : High 38 dB(A) SOUND LEVEL SOUND LEVEL 26 dB(A) 28 dB(A) : Under the unit 1.5m CONDITION CONDITION : Under the unit 1.5m : 220-230-240V, 1 phase, 50Hz...
  • Page 28 4-Way Cassette 60 x 60 (Type Y2) S-36MY2E5A Heating : Distribution of wind velocity (Strong wind : Discharge angle approx.60°) (Room temperature approx.20°C) 1.5m/s 1.0m/s 0.5m/s 0.3m/s Horizontal air flow distance (m) Heating : Distribution of temperature (Strong wind : Discharge angle approx.60°) (Room temperature approx.20°C) Horizontal air flow distance (m) Cooling : Distribution of wind velocity...
  • Page 29 4-Way Cassette 60 x 60 (Type Y2) S-45PY2E5A / 50PY2E5A Heating : Distribution of wind velocity (Strong wind : Discharge angle approx.60°) (Room temperature approx.20°C) 1.5m/s 1.0m/s 0.5m/s 0.3m/s Horizontal air flow distance (m) Heating : Distribution of temperature (Strong wind : Discharge angle approx.60°) (Room temperature approx.20°C) Horizontal air flow distance (m) Cooling : Distribution of wind velocity...
  • Page 30 1-9. Fresh Air Intake 1-9-1. Precautions Regarding External Air Intake (1) Ventilation Load Ensure that the design of the air-conditioner takes air-conditioning loads into consideration when external air intake is involved. (2) Restrictions on External Air Intake Ensure that the design conforms to the restrictions on air intake volume stipulated in accordance with the model of the indoor unit and the intake method.
  • Page 31 1-10. Electrical Wiring General Precautions on Wiring Before wiring, confirm the rated voltage of the unit as shown on its nameplate, then carry out the wiring closely following the wiring diagram. Provide a power outlet to be used exclusively for each unit and a circuit breaker for overcurrent protection should be provided in the exclusive line.
  • Page 32 Wiring System Diagrams * 3-phase model connections Indoor unit (No. 1) Power supply Outdoor unit (3-phase) 220/230/240V ~50Hz INV unit Power supply Ground Remote 380/400/415V, 3 N~, 50Hz controller Ground Ground Ground Indoor unit * Single-phase model connections (No. 2) Power supply Ground Outdoor unit (single-phase)
  • Page 33 CAUTION (1) When linking the outdoor units in a network, disconnect the terminal extended from the short plug from all outdoor units except any one of the outdoor units. (When shipping: In shorted condition.) For a system without link (no wiring connection between outdoor units), do not remove the short plug. (2) Do not install the inter-unit control wiring in a way that forms a loop.
  • Page 34 Wiring samples Type Y2 Functional ground screw Functional ground screw (Schedule Timer) (Louver Motor) Protective ground screw (External Solenoid Valve Kit for 3WAY) Use this screw when connecting the shield for the inter-unit control wiring to ground Remote Power supply cord control wiring Inter-unit control wiring...
  • Page 35 :Cooling Capacity 1-13. Capacity Table SHC :Sensible Heat Capacity 1. Cooling Capacity Performance Data IPT :Cooling Power Consumption • Combination of Single Unit 4-Way Cassette 60×60 Type unit : kW Outdoor air intake temp(°C D.B.) Ambient Power Model Return 25°C 30°C 35°C 40°C...
  • Page 36 :Cooling Capacity 1-13. Capacity Table SHC :Sensible Heat Capacity 1. Cooling Capacity Performance Data IPT :Cooling Power Consumption • Combination of Multiple Unit 4-Way Cassette 60×60 Type unit : kW Outdoor air intake temp(°C D.B.) Ambient Power Model Return 25°C 30°C 35°C 40°C...
  • Page 37 :Cooling Capacity 1-13. Capacity Table SHC :Sensible Heat Capacity 1. Cooling Capacity Performance Data IPT :Cooling Power Consumption • Combination of Multiple Unit 4-Way Cassette 60×60 Type unit : kW Outdoor air intake temp(°C D.B.) Ambient Power Model Return 25°C 30°C 35°C 40°C...
  • Page 38 :Cooling Capacity 1-13. Capacity Table SHC :Sensible Heat Capacity 1. Cooling Capacity Performance Data IPT :Cooling Power Consumption • Combination of Multiple Unit 4-Way Cassette 60×60 Type unit : kW Outdoor air intake temp(°C D.B.) Ambient Power Model Return 25°C 30°C 35°C 40°C...
  • Page 39 1-13. Capacity Table :Cooling Capacity 2. Heating Capacity Performance Data IPT :Cooling Power Consumption • Combination of Single Unit 4-Way Cassette 60×60 Type unit : kW Outdoor air intake temp(°C W.B.) Ambient Power Model Return -5°C 0°C 6°C 10°C 15°C Source 2.00 2.06...
  • Page 40 1-13. Capacity Table :Cooling Capacity 2. Heating Capacity Performance Data IPT :Cooling Power Consumption • Combination of Multiple Unit 4-Way Cassette 60×60 Type unit : kW Outdoor air intake temp(°C W.B.) Ambient Power Model Return -5°C 0°C 6°C 10°C 15°C Source 220V 2.88...
  • Page 41 1-13. Capacity Table :Cooling Capacity 2. Heating Capacity Performance Data IPT :Cooling Power Consumption • Combination of Multiple Unit 4-Way Cassette 60×60 Type unit : kW Outdoor air intake temp(°C W.B.) Ambient Power Model Return -5°C 0°C 6°C 10°C 15°C Source 2.09 2.19...
  • Page 42 3. ELECTRICAL DATA 3-1. Indoor Units (Electric Wiring Diagram Schematic Diagram) ........3-2 4-Way Cassette Type ..........................3-2 4-Way Cassette 60 × 60 Type ......................... 3-3 Ceiling Type ............................3-4 Wall Mounted Type ..........................3-5 Low Silhouette Ducted Type ........................3-6 Ducted Type ............................
  • Page 43: Indoor Units

    3-1. Indoor Units 4-Way Cassette 60 × 60 Type S-36PY2E5A / S-45PY2E5A / S-50PY2E5A Electric Wiring Diagram...