Haier 1U25JEJFRA Service Manual page 53

Wall mounted type dc inverter
Hide thumbs Also See for 1U25JEJFRA:
Table of Contents

Advertisement

11.5 Heating capacity-temperature curves
outdoor temp.
DB/WB
-15℃
-10℃
-7/-8℃
2/1℃
7/6℃
12/11℃
18/16℃
24/20℃
4000
3500
3000
2500
2000
1500
1000
500
0
performance curves
heating capacity and indoor/outdoor temp.table
15℃
1820
2797
3438
3791
3577
3202
2620
2102
heating capacity and indoor/outdoor temp.curves
outdoor tempe.(DB/WB)
indoor temp.(humidity 46%)
20℃
1696
2558
3117
3423
3303
2950
2470
1889
52
Performance and curves diagrams
25℃
1618
2359
2897
3105
2811
2572
2166
1685
Domestic air conditioner
15℃
20℃
25℃

Advertisement