Download Print this page

Table Of Contents; Introduction; Warranty - Craftsman 390.250255 Owner's Manual

Shallow well jet pump

Advertisement

CONTENTS
Introduction ...............................................................2
Warranty .....................................................................2
Major System Components ........................................3
Installation..............................................................4, 5
Electrical.....................................................................6
Maintenance ............................................................7-8
Troubleshooting .........................................................9
Repair Parts .........................................................10-11
For one year from the date of purchase, Sears will repair or replace this pump, free of charge, if defective in material or
workmanship.
This warranty does not cover repairs or replacement parts necessary because of abuse or negligence including failure to
install, adjust and operate this pump according to the instructions in the owner's manual.
SEARS WILL NOT BE LIABLE FOR LOSS OR DAMAGE TO PROPERTY OR ANY INCIDENTAL OR CONSEQUENTIAL LOSS
OR EXPENSE FROM PROPERTY DAMAGE DUE DIRECTLY OR INDIRECTLY FROM THE USE OF THIS PRODUCT.
Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or ex-
clusion may not apply to you.
WARRANTY SERVICE IS AVAILABLE BY SIMPLY CONTACTING THE NEAREST SEARS SERVICE CENTER/DEPARTMENT
IN THE UNITED STATES.
This warranty applies only while the product is in use in the United States.
This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
RULES FOR SAFE INSTALLATION AND OPERATION
1. Read the Owners Manual and Rules for Safe
Operation and Installation Instructions carefully.
Failure to follow these Rules and Instructions could
cause serious bodily injury, and/or property dam-
age.
2. Check your local electrical wiring codes before in-
stallation. If your local codes are not followed, your
pump will not work to its full rated capacity and
could present a fire hazard. If in doubt, contact your
local power company.
3. BE SURE your pump installation meets all local
plumbing, pump and well codes.
4. While installing your pump, always keep the well
covered to prevent leaves and foreign matter from
falling into the well, contaminating the water
and/or causing possible serious damage to the me-
chanical operation of the pump.
5. Always test the water from well for purity before
using. Check with local health department for test-
ing procedure.
6. Before installing or servicing your pump, BE SURE
pump power source is disconnected.
7. BE SURE your pump electrical circuit is properly
grounded.
FULL ONE YEAR WARRANTY ON CRAFTSMAN
LIMITATION OF LIABILITY
Sears, Roebuck and Co., Dept. 817 WA, Hoffman Estates, IL 60179

INTRODUCTION

Please read our instructions before installing and using
your pump. This will help you obtain the full benefits
of the quality and convenience built into this equip-
ment. It will also help you avoid any needless service
expense resulting from causes beyond our control
which are not covered by our warranty.
®
WELL PUMP
8. Complete pump and piping system MUST be pro-
tected against below freezing temperature.
Allowing the pump or piping to freeze could cause
severe damage and voids the Warranty.
9. BE SURE the line voltage and frequency of the elec-
trical current supply agree with the motor wiring
as shown on motor nameplate.
10. The correct fusing and wiring sizing is essential to
proper motor operation. Use recommended fusing
and wire size data in the manual (Page 6).
11. Pump water only with this pump.
12. Periodically inspect pump and system components.
13. Relief valve must be capable of passing full pump
flow at 75 PSI.
Pump body may explode if used as a
booster pump unless relief valve ca-
pable of passing full pump flow at 75 PSI (517
kPa) is installed.
Motor normally operates at high tempera-
ture and will be too hot to touch. It is pro-
tected from heat damage during operation by an
automatic internal cutoff switch. Before handling
pump or motor, stop motor and allow it to cool for 20
minutes.
2

Advertisement

loading