9.7 Control of standby function (None)

9.8 Control of ice make

9.9 Fault code and solutions

Fault
Fault content
code
Temperature sensor fault
E1
in refrigerating chamber
Temperature sensor fault
in freezer chamber
E2
Temperature sensor fault
in chiller chamber
E3
E5
Fault of F frost sensor
E6
Communication failure
Ambient
E7
sensor fault

9.10Defrosting function

1.Defrost the freezing chamber as per the accumulative operation time of the Compressor
2.If power failure occurs abruptly to the Compressor and the defrosting sensor in freezing chamber
o
is less than 0
C after powering on, then first conduct defrosting once. If more than 0
defrosting is not needed.
After that, conduct defrosting according to using condition and ambient temperature in a period
between 6 and 24 hours as per the accumulative operation time of the Compressor.
Service Manual, 2017-8
(None)
r
Steps for maintenance methods
Step 1: Check whether the terminal CN5 is well stuck, pull out the
terminal and re-stick it in place
Step 2: Check to see if there're foreign matters on the terminal.
Step 3: inspect the refrigerating sensor whether contact is bad, and
resend contact the fast connector
Step 4: Replace main control board
Step 1: Check whether the terminal CN5 is well stuck, pull out the
terminal and re-stick it in place
Step 2: Check to see if there're foreign matters on the terminal.
Step 3: inspect the freezer sensor whether contact is bad, and resend
contact the fast connector
Step 4: Replace main control board
Step 1: Check whether the terminal CN5 is well stuck, pull out the
terminal and re-stick it in place
Step 2: Check to see if there're foreign matters on the terminal.
Step 3: inspect the chiller sensor whether contact is bad, and resend
contact the fast connector
Step 4: Replace main control board
Step 1: Check whether the terminal CN5 is well stuck, pull out the
terminal and re-stick it in place
Step 2: Check to see if there're foreign matters on the terminal.
Step 3: inspect the defrost sensor whether contact is bad, and resend
contact the fast connector
Step 4: Replace main control board
Step 1: Check whether the terminal CN9 is well stuck, pull out the
terminal and re-stick it in place
Step 2: Check to see if there're foreign matters on the terminal.
Step 3: inspect the display control board terminal whether contact is
bad, and resend contact the fast connector
Step 4: Replace main control board
Step 5: Replace display control boardStep 6: Replace main wire
Step 1: Check whether the terminal CN2 is well stuck, pull out the
temperature
terminal and re-stick it in place
Step 2: Replace ambient temperature sensor
o
C, then
34 / 51