Test Mode; Self-Diagnosis - Toshiba CE-BCD308WE2-JT Service Manual

Table of Contents

Advertisement

9.11Test mode

Test
Test items
module
Enter Test
Mode
Select to
enter into
forced
cooling mode
Test
Mode
Select to
enter into
forced
defrosting
mode

9.12Self-diagnosis

Conditions for entering into this mode
When the power is on for the first time, here is no sensor failure and the defrost sensor
temperature is equal to or more than 0° C.
Self-diagnosis process
1、Defrost heater is on for 2 seconds and off for 2 seconds;
2.The fan is on for7 seconds and off for 3 seconds;
3.damper on 2seconds and off for 2 seconds;
4. The refrigerator light on 2seconds and off for 2 seconds;
Service Manual, 2017-8
Testing Method
Long press both vacation
button and temperature
setting button of
refrigerator room for 4s
In test mode, if no new
mode set, lock the panel
In test mode("0" on display
panel), click the vacation
button,
In mandatory cooling
mode, if there is no
operation on display panel
in 36 hours
In mandatory cooling
mode("1" on display
panel),click the vacation
button
In mandatory defrost
mode, when the
temperature of defrost
sensor arrives 12℃ and
the defrost heater has
worked for 3 minutes
In mandatory defrost
mode, when the
temperature of defrost
sensor is lower than 12 ℃
and the defrost heater
has worked for 1 hour
Expected result
It indicates "0" on display panel, and buzzer
sounds once, the refrigerator enter in test mode
The refrigerator will exit test mode, and return
back to normal running
The display panel indicates "1",the refrigerator
enters in mandatory cooling mode, the
compressor and fan start to work mandatorily,
and the air damper is opened.
The refrigerator exits test mode, and return back
to normal running
The display panel indicates "3", the refrigerator
enters in mandatory defrost mode, the
compressor and fan stops working, and the air
damper is closed
The refrigerator will exit mandatory defrost
mode and return back to normal running
The refrigerator will exit mandatory defrost
mode and return back to normal running
35 / 51

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

22031020002961

Table of Contents