LG ABNW18GBHC0 Engineering Product Data Book page 39

Hide thumbs Also See for ABNW18GBHC0:

Advertisement

Compact
7. Sound level
7.1 Sound Pressure level
Overall
DISCHARGE
DUCT
2m
Model
ABNW30GM1A0 [UM30 N14]
ABNW36GM2A0 [UM36 N24]
h
indicates values at 'Standard Mode'.
External Static Pressure 2.5(25) [mmAq(Pa)]
ABNW30GM1A0 [UM30 N14]
80
70
60
50
40
30
20
Approximate
Hearing
Threshold
10
63
125
250
500
Octave Band Center Frequency (Hz)
14 _
Ceiling concealed duct - Middle static pressure(2)
Indoor unit
SUCTION
DUCT
1.5m
2m
Sound Pressure Levels (dB(A),H-M-L)
External Static Pressure [mmAq(Pa)]
2.5(25)
4(39)
37-35-34
39-37-35
-
36-34-33
n
High
▲ Mid
l Low
NC-65
NC-60
NC-55
NC-50
NC-45
NC-40
NC-35
NC-30
NC-25
NC-20
NC-15
1 000 2 000 4 000 8 000
Notes:
1. Sound measured at 1.5m away from the center of the unit.
2. Operating condition
- Power source : 220-240V 50Hz / 220V 60Hz
- Cooling : Indoor temperature (27°C DB, 19°C WB),
Outdoor temperature (35°C DB, 24°C WB)
- Heating : Indoor temperature (20°C DB, 15°C WB),
Outdoor temperature (7°C DB, 6°C WB)
3. Reference acoustic intensity 0dB = 20μPa.
4. Sound level will vary depending on a range of factors such as the
construction (acoustic absorption coefficient) of particular room in
which the equipment is installed.
5(49)
7(69)
10(98)
40-38-36
41-39-38
42-41-39
37-36-34
38-37-35
39-38-37
15(147)
43-42-41
42-40-39