SW-D2 No. 5 Reserved
Set to "0".
SW-D2 No. 6, No. 7 CI off detection timer (Distinctive ring setting
off only)
Set the minimum time period of CI signal interruption which affords to
be judged as a CI OFF section.
A
1
400msec
SW-D2 No. 8 Reserved
Set to "0".
SW-E1 No. 1 Automatic switching mode
Used to set auto TEL/FAX switching mode or to set the normal fax
mode.
SW-E1 No. 2, No. 3 Pseudo ringing time at the phone/fax auto-
matic switching mode
Choice is made as to how long to rumble the dummy ringer on
TEL/FAX automatic switching mode.
SW-E1 No. 4 Number of CNG signal detection at the phone/fax
automatic switching mode.
Used for detection of CNG in one tone or two tones in the TEL/FAX
automatic switching mode.
SW-E1 No. 5 CNG detect time at TEL/FAX mode
The switch which sets the time from the start of the CNG detection to
the end in the TEL/FAX automatic switching mode.
SW-E1 No. 6 Reserved
Set to "0".
SW-E1 No. 7 Post answer tone transmit in TEL/FAX mode
When set to "0", machine send the 3 tones (880Hz/988Hz/1046Hz) in
TEL/FAX auto changeover mode.
SW-E1 No. 8 Reserved
Set to "0".
SW-E2 No. 1 ~ No. 4 Pseudo ringer sound output level to the line
Used to adjust the sound volume of pseudo ringer to the line (ring
back tone) generated on selecting TEL/FAX. Setting is the reduce
level from -5dBm output level.
(Example) If the reduce level is -5dBm, set by binary input "0" "1" "0"
"1" (5), then output level is -10dBm (-5dBm -5dBm)
If the reduce level is -8dBm, set by binary input "1" "0" "0"
"0" (8), then output level is -13dBm (-5dBm -8dBm)
SW-E2 No. 5 ~ No. 8 Reserved
Set to "0".
SW-F1 No. 1, No. 2 DTMF detect time
Used to set detect time of DTMF (Dual Tone Multi Frequency) used in
remote reception (5
).
The longer the detect time is, the less the error detection is caused by
noises.
SW-F1 No. 3 Remote reception (5
Used to set the function of remote reception (5
"1", the remote reception function is disabled.
B
2
2000msec
) detect
). When set to
2 – 13
SW-F1 No. 4 Remote reception
(Corresponding to TEL made by GE) P.B.X.
"1": Compatible with TEL mode by GE
"0": Not compatible
When sending (5
) for remote reception with a GE manufac-
tured telephone remote reception may not take place because of
special specifications in their DTMF.
To overcome this, a soft SW is provided to change the modem
setting to allow for remote reception.
If this soft SW is set to "1", other telephone sets may be adversely
affected.
SW-F1 No. 5 ~ No. 8 Remote operation code figures by external
TEL
Remote operation codes can be changes from 0 through 9. If set to
greater than 9, it defaults to 9. The "5
Ex-7
(Default: 5
)
SW-F2 No. 1 CNG signal detection in standby condition
When setting to "1", the CNG signal detection function during standby
stops.
SW-F2 No. 2, No. 3 Number of CNG signal detection (AM)
Used for detection of CNG in 1 to 4 pulses.
SW-F2 No. 4, No. 5 Number of CNG signal detection (STAND-BY
mode)
Used for detection of CNG in 1 to 4 pulses.
SW-F2 No. 6 ~ No. 8 Reserved
Set to "0".
SW-G1 No. 1 ~ No. 4 Quiet detect time (Used in answering ma-
chine mode)
When an answering machine is connected, if a no sound state is
detected for a certain period of time, the machine judges it as a
transmission from a facsimile machine and automatically switches to
the FAX mode.
SW-G1 No. 5 ~ No. 8 Quiet detect start timing (Used in answering
machine mode)
Inserts a pause before commencing quiet detection.
SW-G2 No. 1 ~ No. 8 Reserved
Set to "0".
SW-G3 No. 1 ~ No. 3 Reserved
Set to "0".
SW-G3 No. 4 TAD connected
When connecting the answering machine to the extension telephone
jack, set to "1".
SW-G3 No. 5, No. 6 Section time of quiet detection.
The switch which sets the time from the start of detection function to
the end of the function.
SW-G3 No. 7, No. 8 Reserved
Set to "0".
SW-H1 No. 1 Busy tone detection ON/OFF time (Lower limit).
The initial value of detection is set according to electric condition.
The set value is changed according to the local switch board. (Erro-
neous detection of sound is reduced.)
Normally the upper limit is set to 750 msec, and the lower limit to 200
msec.
If erroneous detection is caused by sound, etc.. adjust the detection
range.
The lower limit can be set in the range of 350 msec to 200 msec.
FO-165A
FO-365A
" is not changed.