Sharp FO-165 Service Manual page 40

Hide thumbs Also See for FO-165:
Table of Contents

Advertisement

FO-165A
FO-365A
11
Wire treatment
a. Perform wire treatment carefully and deliberately.
b. For wire treatment procedures which are not described in this
section, refer to the section for that portion of the unit.
THE HEAD CABLE WILL BE PASSED
TO THE CORE AT 3 TIMES.
2
DON'T OVER THIS
LINE BY CABLE.
(KEEP TO ARROW SIDE)
THE SCANNER CABLES WILL BE
PASSED TO THE CORE 2 TIMES.
2
POSITION OF
CORE
2
2
2
IT WILL BE HOOKED THE CABLES BETWEEN
THE HOOKING RIBS.
1
Parts list (Fig. 11)
No.
1
Band
2
Core
DON'T ON THIS
CORE TO PWB
1
2
1
A
IT WILL BE PASSED THE
CABLE BEHIND THE DRIVE
UNIT AS ARROW A DIRECTION.
Fig. 11
3 – 16
Part name
2
THE DRIVE UNIT CABLES WILL
BE PASSED TO THE CORE AT 2 TIMES.
2
1
1
FIX THE CORE
LIKE A PICTURE
Q'ty
1
3
2
rib