3. Remove plastic tag holding three 10-32 hex nuts from the
middle post of the terminal block.
4. Assemble a UL listed strain relief in the opening.
A. UL listed strain relief
5. Complete installation following instructions for your type of
electrical connection:
4-wire (recommended)
3-wire (if 4-wire is not available)
Electrical Connection Options
And you will be
If your home has:
connecting to:
3-wire receptacle
A UL listed, 250 V
(NEMA type 10-
minimum, 40 or
50R)
50 A, range power
supply cord
4-wire receptacle
A UL listed, 250 V
(NEMA type 14-
minimum, 40 or
50R)
50 A, range power
supply cord
3-Wire Connection: Power Supply Cord
Use this method only if local codes permit connecting chassis
ground conductor to neutral wire of power supply cord.
1. Feed the power supply cord through the strain relief on the
2. Use 3/8" (1.0 cm) nut driver to connect the neutral (white) wire
Go to Section:
3-Wire Connection:
Power Supply Cord
4-Wire Connection:
Power Supply Cord
3. Connect line 2 (red) and line 1 (black) wires to the outer
4. Securely tighten 20 lbs-in (2.3 N-m) recommended torque to
cord/conduit plate on bottom of range. Allow enough slack to
easily attach the wiring to the terminal block.
A. Terminal block
B. Ground-link screw
C. UL listed strain relief
D. Power supply cord wires - large opening
to the center terminal block post with one of the 10-32 hex
nuts.
A. 10–32 hex nut
B. Line 2 (red) wire
C. Ground-link screw
terminal block posts with 10-32 hex nuts.
tighten hex nuts.
NOTE: For power supply cord replacement, use only a power
cord rated at 250 V minimum, 40 A or 50 A that is marked for
use with nominal 1
3
/
" (3.5 cm) diameter connection opening,
8
with ring terminals and marked for use with ranges.
D. Neutral (white) wire
5.
Line 1 (black) wire
15