Download Print this page
Sealey PC380M110V Manual

Sealey PC380M110V Manual

38l dust-free wet & dry industrial vacuum cleaner stainless steel drum class m filtration

Advertisement

Quick Links

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions,
and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
Refer to
Vacuum cleaners of dust category M
instruction
according to IEC/EN 60335-2-69 for
manual
dry vacuuming of hazardous dusts
with an exposition limit value ≥0.1
mg/m3
1. SAFETY
1.1.
ELECTRICAL SAFETY
WARNING! It is the responsibility of the owner and the operator to read, understand and comply with the following:
You must check all electrical products, before use, to ensure that they are safe. You must inspect power cables, plugs, sockets and
any other connectors for wear or damage. You must ensure that the risk of electric shock is minimised by the installation of appropriate
safety devices. A Residual Current Circuit Breaker (RCCB) should be incorporated in the main distribution board. We also recommend
that a Residual Current Device (RCD) is used. It is particularly important to use an RCD with portable products that are plugged into a
supply which is not protected by an RCCB. If in any doubt consult a qualified electrician. You may obtain a Residual Current Device by
contacting your Sealey stockist.
You must also read and understand the following instructions concerning electrical safety.
9
1.1.1.
The Electricity at Work Act 1989 requires that all portable electrical appliances, if
used on business premises, are tested by a qualified electrician, using a Portable
Appliance Tester (PAT), at least once a year.
1.1.2.
The Health & Safety at Work Act 1974 makes owners of electrical appliances
responsible for the safe condition of those appliances and the safety of the appliance
operators. If in any doubt about electrical safety, contact a qualified electrician.
Ensure that the insulation on all cables and on the appliance is safe before connecting
9
it to the power supply.
Ensure that cables are always protected against short circuit and overload.
9
Regularly inspect power supply cables and plugs for wear or damage and check all
9
connections to ensure that none are loose.
Ensure that the voltage marked on the appliance matches the power supply to be used.
9
DO NOT pull or carry the appliance by its power supply lead.
8
DO NOT pull the plug from the socket by the power cable.
8
DO NOT use worn or damaged cables, plugs or connectors. Immediately have any
8
faulty item repaired or replaced by a qualified electrician.
Ensure the unit is correctly earthed via a three-pin 110V plug.
9
a) Connect the GREEN/YELLOW earth wire to the earth terminal 'PE'.
b) Connect the BROWN live wire to the live terminal 'L/+'.
c) Connect the BLUE neutral wire to the neutral terminal.
d) After wiring, check that there are no bare wires, that all wires have been correctly
connected, that the cable outer insulation extends past the cable restraint and that the
restraint is tight.
1.2.
GENERAL SAFETY
Safety precautions must be observed to avoid injuries and damage. Read the complete operating manual carefully. Keep this manual
9
in a safe place so that the information is always available to ANY users of the equipment.
Never leave the appliance switched on unattended. If the operator leaves the work area, switch the appliance off or unplug it from the
9
power supply.
DO NOT vacuum or use this vacuum cleaner near flammable liquids, gases or explosive vapours like gasoline or other fuels,
8
lighter fluids, cleaners, oil-based paints, natural gas, hydrogen, or explosive dusts like coal dust, magnesium dust, grain dust or gun
power. Sparks inside the motor can ignite flammable vapours or dust.
This vacuum cleaner is not suitable for the vacuuming of asbestos or asbestos dust.
9
DO NOT vacuum anything that is burning or smoking, such as cigarettes, matches, or hot ashes.
8
Ensure the hose and connections are always pointed away from the users face, hair, ears and eyes during operation and never direct
9
the nozzle towards persons or animals.
Clear the working area of any items or possessions that do not need to be vacuumed before using equipment
9
Keep mains cable away from heated surfaces.
9
DO NOT expose to rain. Store indoors.
8
DO NOT unplug by pulling on the mains cable. To unplug, grasp the plug, not the cable.
8
DO NOT use with damaged cord, plug or other parts.
8
© Jack Sealey Limited
38L DUST-FREE WET & DRY INDUSTRIAL
VACUUM CLEANER STAINLESS STEEL DRUM
CLASS M FILTRATION
PC380M110V
MODEL NO:
Wear protective
clothing
.
Original Language Version
Wear a P-2
respirator when
changing bags,
filter or
cartridges
Fuse rating: 16 Amp
PC380M110V Issue:1 08/04/21

Advertisement

loading

Summary of Contents for Sealey PC380M110V

  • Page 1 PC380M110V MODEL NO: Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble free performance. IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED.
  • Page 2: Specification

    >0.1mg/m³. When the air velocity starts to fall below 20 metres per second a visual LED warning light on the top of the unit will show. Built-in push clean system that forces air back through the filter restoring the suction power. Uses a combination of filters and lining bags to create a 2-stage collection to stop any hazardous dust being left in the tank or becoming airborne, it also has the option of using a foam filter for wet cleaning which is reusable (all consumables are included, 5 x Tank liners, 5 x dust bags and 1 x foam filter). Included accessories are antistatic crevice tool, antistatic round brush, multi-surface floor nozzle 12” and Power tool adaptor. 3. SPECIFICATION Model no ............PC380M110V Airflow ..............147.6m³/hr Consumable parts Foam filter (x3) ............. PC380MFF Cartridge filter Class M ........PC380MCF Tank liner Class M (x5) ........PC380MTL, Dust bag class M (x5) ........
  • Page 3 Unfold the upper handle assembly into the upright position. The upper handle has two adjustable height positions. Secure in place by tightening the knobs clockwise (Fig. 5). 5.7. The vacuum cleaner comes ready for dry vacuum cleaning with the cartridge filter pre-installed. If the cartridge filter is not installed, refer to section 6.6. 5.8. To maintain M-class certification this vacuum cleaner must be used with a means of disposable collection. By removing the dust bag and disposable bag when collecting debris the user runs the risk of voiding vacuum cleaner certification. 5.9. To use a dust bag, fully fit the dust bag flange onto the inlet stub (Fig. 6). Original Language Version PC380M110V Issue:1 08/04/21 © Jack Sealey Limited...
  • Page 4: Operation

    6. OPERATION 6.1. SWITCHING ON/OFF 6.1.1. Connect the mains plug to a suitable power outlet. 6.2. POWER TOOL TAKE-OFF OPERATION (FIG. 13) WARNING! Always check the maximum wattage compatibility of the power tool take off socket against the desired power tool before ‰ connecting to prevent overloading. 6.2.1. Connect the power cable of your power tool to the power take-off socket. Original Language Version PC380M110V Issue:1 08/04/21 © Jack Sealey Limited...
  • Page 5: Power Regulator

    WARNING! BEFORE INSTALLING, REMOVING OR CLEANING THE VACUUM CLEANER FILTER, ENSURE THAT THE POWER ‰ CORD IS SWITCHED OFF AND UNPLUGGED. WARNING! ALWAYS USE A P2-RESPIRATOR WHEN VACUUMING HAZARDOUS DUSTS. ‰ © Jack Sealey Limited Original Language Version PC380M110V Issue:1 08/04/21...
  • Page 6: Maintenance

    If your motor is operating, then the most likely cause for a loss in suction is a blockage or an opening in the vacuum. To maintain a high cleaning performance from your machine, it is important to replace or clean cartridge filters as necessary. 8.1.2. Replace full dust collection bags to prevent performance drops. A performance drop with clean filters can only be caused by a blockage in the tools or the hose. PC380M110V Issue:1 08/04/21 Original Language Version © Jack Sealey Limited...
  • Page 7: Weee Regulations

    Important: No Liability is accepted for incorrect use of this product. Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim. Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR 01284 757500 01284 703534 sales@sealey.co.uk...