Power Supply Cord Kit (U.s.a.); Factory Connected Power Supply Cord (Canada Only) - Electrolux ICON Professional E30DF74GPS Installation Instructions Manual

30" & 36" dual fuel range
Hide thumbs Also See for ICON Professional E30DF74GPS:
Table of Contents

Advertisement

30" & 36" DUAL FUEL RANGE INSTALLATION INSTRUCTIONS
2.A

Power Supply Cord Kit (U.S.A.)

The user is responsible for connecting the power supply
cord to the connection block located behind the back
panel access cover.
This appliance may be connected by means of
permanent "hard wiring" (flexible armored or
nonmetallic shielded copper cable), or by means of a
power supply cord kit. Use only a power supply cord kit
rated at 125/250 volts minimum and marked for use
with ranges. Cord must have either 3 or 4 conductors.
Terminals on end of wires must either be closed loop or
open-end spade lugs with upturned ends. Cord must
have strain relief clamp.
A 3-wire* or 4-wire single phase 120/240 or 120/208
Volt, 60 Hz AC only electrical supply is required on a
separate circuit fused on both sides of the line (time-
delay fuse or circuit breaker is recommended). DO NOT
fuse neutral. The fuse size must not exceed the circuit
rating of the appliance specified on the nameplate.30"
Range: Use a circuit breaker of 20 Amp; 36" Range:
Use a circuit breaker of 30 Amp.
* For mobile homes, new installations, recreational
vehicles, or areas where local codes do not permit
grounding through neutral, a 4 conductor power
supply cord kit rated at 125/250 volts and marked
for use with ranges should be used (see Figure 10).
2.B
Factory Connected Power
Supply Cord (Canada only)
Your range is equipped with a factory-connected power
cord (see Figure 3). Cord must be connected to a
grounded 120/240 volt or 120/208 volt range outlet. If
not outlet is available, have one installed by a qualified
electrician.
Figure 3
3.
Junction Box or Wall
Receptacle Location
Suggested location of the junction box or wall
receptacle is showed in Figure 4 for 30" Range and
on figure 5 for 36" Range. It can also be located in
the lower left corner of the adjacent right cabinet
(see Figure 6). If a service cord is used, the wall
receptacle should be located in accordance with the
dimensions below.
(Model with Electric Oven and Gas Cooktop)
(25.4 cm)
7" Max.
(17.8 cm Max.)
Locate Electrical Hook-up
Inside Shaded Area
30" Range Junction Box or Wall Receptacle Location
W A L L
36" Range Junction Box or Wall Receptacle Location
• Electrical ground is required on this appliance.
• Do not connect to the electrical supply until
appliance is permanently grounded.
• Disconnect power to the circuit breaker or fuse
box before making the electrical connection.
• This appliance must be connected to a
grounded, metallic, permanent wiring system,
or a grounding connector should be connected
to the grounding terminal or wire lead on the
appliance.
• Do not use the gas supply line for grounding
the appliance.
Failure to do any of the above could result in a
fire, personal injury or electrical shock.
4
Center
Line of
Range
10"
W A L L
Center
Line of
Range
Figure 4
Center
Line of
Range
10"
(25.4 cm)
5" Max.
(1
2.7
cm Max.)
Locate Electrical Hook-up
Inside Shaded Area
Center
Line of
Range
Figure 5
8"
(20.3 cm)
12"
(30.5 cm)
Figure 6
Electrical Shock Hazard

Hide quick links:

Advertisement

Table of Contents