Electrical Connection To The Range; Three Conductor Wire Connection To Range - Electrolux ICON Professional E30DF74GPS Installation Instructions Manual

30" & 36" dual fuel range
Hide thumbs Also See for ICON Professional E30DF74GPS:
Table of Contents

Advertisement

30" & 36" DUAL FUEL RANGE INSTALLATION INSTRUCTIONS
4.

Electrical Connection to the Range

This appliance is manufactured with the neutral terminal
connected to the range.
While connecting range, do not
loosen the nuts which secure the terminal block to
the range. Electrical failure or loss of electrical
connection may occur.
Note: Refer to the wiring diagram at the end of this
manual.

Three Conductor Wire Connection to Range

(The 3-conductor cord or cable must be replaced with a
4-conductor cord or cable where grounding through the
neutral conductor is prohibited in new installations,
mobile homes, recreational vehicles or in other areas
where local codes do not permit neutral grounding)
If local codes permit connection of the frame
grounding conductor to the neutral wire of the
power supply cord (Figure 9):
1. Remove the screws
at the lower end of
the rear wire access
panel or cover, then
remove the access
cover or lift the
lower part of the
access panel to
expose range
terminal connection
block (Fig. 7 or 8).
Pressure regulator
Pressure
Rear wire
regulator
access panel
location
Figure 8 - 36" Range
(Model with Electric Oven and Gas Cooktop)
Rear wire
access cover
location
Figure 7 - 30" Range
Risk of fire or electrical shock exists if
an incorrect size range cord kit is used, if the
Installation Instructions are not followed, or if the
strain relief bracket is discarded.
2. Remove the 3 loose nuts on the terminal block using
3/8" nut driver or socket.
3. Connect the neutral white wire of the power supply
cord to the center silver-colored terminal of the
terminal block, and connect the other wires to the
outer terminals. Match terminal and power supply
wires by color.
4. Replace the 3 nuts on the terminal block (Figure 9).
5. Replace the rear access cover or panel using the
screws removed on step 1.
Three Conductor or Wire Connection to Range
5
Figure 9