8-5. TEST OUT Level Adjustment

8-6. Modulator Balance Adjustment

8-5. TEST OUT Level Adjustment
Preparation
. OUTPUT/DCC switch (inside panel) → BARS
. On the setting menu, set as follows.
PAGE
: LEVEL 7
: TEST OUT → R, G or B
ITEM
Adjustment procedure
Test point: TEST OUT connector
1. On the setting menu, adjust as follows.
PAGE
: LEVEL 5
ITEM
: RGB SYNC LEV.
: A = 40 ± 2 IRE (NTSC)
Spec.
A = 300 ±14 mV (PAL)
2. On the setting menu, adjust as follows.
PAGE
: LEVEL 5
ITEM
: RGB SETUP LEV.
: B = 7.5 ± 0.5 IRE (NTSC)
Spec.
B = 0 ± 3 mV (PAL)
3. On the setting menu, adjust as follows.
PAGE
: LEVEL 5
ITEM
: RGB LEVEL
: C = 100 ± 2 IRE (NTSC)
Spec.
C = 700 ±14 mV (PAL)
NTSC
R
C
B
A
Setting after adjustment
. On the setting menu, set as follows.
PAGE
: LEVEL 7
: TEST OUT → ENC
ITEM
8-6
PAL
R
C
B
A
8-6. Modulator Balance Adjustment
Preparation
. WHITE BAL switch (inside panel) → PRST
. OUTPUT/DCC switch (inside panel) → CAM/ON
Adjustment procedure
1. AUTO W/B BAL switch (front panel) → BLK
Hold this switch in BLK state untilthe message
"_MOD BAL_" on the viewfinder is displayed .
2. A few seconds later after releasing the switch, check
that the message "BLACK OK" is displayed on the
viewfinder.